Skip to main content
  • Research article
  • Open access
  • Published:

Iodine-doped TiO2 nanotube coatings: a technique for enhancing the antimicrobial properties of titanium surfaces against Staphylococcus aureus

Abstract

Background

Implant-related infections are a challenging complication of orthopedic surgery, primarily due to the formation of bacterial biofilms on the implant surface. An antibacterial coating for titanium implants was developed to provide novel insights into the prevention and treatment of implant-related infections.

Methods

Titanium plates were coated with TiO2 nanotubes by anodization, and iodine was doped onto the coating via electrophoretic deposition. The obtained plates were characterized using a range of analytical techniques. Subsequently, Staphylococcus aureus was inoculated onto the surfaces of untreated titanium plates (control group), TiO2-nanocoated titanium plates (TiO2 group), and iodine-doped TiO2-nanocoated titanium plates (I-TiO2 group) to compare their antibacterial properties.

Results

Twenty-four hour in vitro antimicrobial activity test of the I-TiO2 group against Staphylococcus aureus was superior to those of the other groups, and this difference was statistically significant (Pā€‰<ā€‰0.05).

Conclusions

This coating technology provides a new theoretical basis for the development of anti-infective implants against Staphylococcus aureus in orthopedics.

Background

Infection is a prevalent and formidable complication of orthopedic implant placement and poses significant challenges to surgical practice. Despite the implementation of stringent anti-infection measures, various studies have revealed that the infection rates after total hip arthroplasty and total knee arthroplasty remain at 2.2 and 0.54% [1, 2]. Alarmingly, there are reports suggesting that pinhole infection rates associated with external fixation can reach as high as 70% [3]. Once an implant-related infection occurs, it necessitates a costly and time-consuming treatment, inflicting substantial physical and psychological distress on the patient. These infections impose an immense burden on the patients, their families, and national healthcare resources, especially when implant removal is also required. The primary etiology of medical implant-associated infections lies in the adhesion of bacteria to an implant surface, which subsequently leads to progressive bacterial biofilm (BBF) formation. In this context, Costerton et al. [4] initially proposed the biofilm theory while conducting research into its occurrence and development processes, i.e., attachment and adhesion, colonization, aggregation, maturation, and detachment. In addition, Gristina et al. [5] explored the relationship between bacterial biofilms and their hosts by introducing the concept of the ā€œsurface competition theory.ā€ According to this theory, if host functional cells adhere to the surface of the prosthesis at the same time as the bacteria, the host cells will effectively ā€œoccupyā€ it; however, if bacteria dominate, prosthetic failure ensues. Furthermore, osseointegration can occur when the host cells prevail over the adherence of bacteria to the surfaces of prostheses. Upon initial adherence to an implant surface, the bacteria gradually develop into biofilms capable of resisting the immune attacks led by host cells through the production of extracellular matrix polymers [6].

To prevent bacterial adhesion and colonization, the modification and surface engineering of implants are current prominent areas of research. Various biocompatible materials that exhibit antibacterial properties have been investigated for the coating of endophyte surfaces. Common coatings employed to date include inorganic, organic, and anti-adhesive coatings, among others [7]. Inorganic antibacterial coatings based on metal ions (e.g., copper, silver, mercury, zinc, or palladium) or metal oxides (e.g., zinc oxide, titanium dioxide, magnesium oxide, or copper oxide) are commonly used. Although silver ion-based antimicrobial agents have received extensive attention because of their strong broad-spectrum antibacterial properties [8], biocompatibility issues and the potential cytotoxic effects associated with the release of silver ions cannot be overlooked [9]. Organic coatings are another major class of surface modification materials. These bioactive coatings transform implants into modules of sustained antibiotic release by incorporating antibiotics either inside or on the surface of the implant via direct or indirect means. Such a localized antibiotic delivery approach specifically targets infections [10]. Thus, by reducing the systemic toxicity and allowing precise control over drug release rates throughout the treatment duration, this method ensures consistent therapeutic dosing over an extended period without peaks or troughs. In addition, the ability to regulate the antibiotic release rate ensures a consistent therapeutic dosage, prevents fluctuations, and enables safe and prolonged drug release. However, Schierholz et al. [11] highlighted that an optimal local effect can only be achieved when the local antibiotic concentration is 1000 times higher than that in local lesions treated with intravenous antibiotics. Furthermore, controlling the sustained-release rate of drugs is challenging because short-term and high-concentration release can lead to tissue damage around the implant. Additionally, it remains uncertain whether loaded antibiotics are effective against pathogenic bacteria. Thus, the development and application of antibiotic coatings must be examined in much greater detail to address such issues.

As an alternative approach, adhesion barrier coatings aim to modify certain physical properties of the implant surface to prevent bacterial adhesion and colonization, with example target properties including the surface roughness, electrical energy, potential viscosity, and electrical conductivity [12, 13]. However, most antibacterial modifications for implants exhibit varying degrees of drawbacks, including an uncontrolled antibiotic release efficiency, histocompatibility, cytotoxicity concerns related to silver ion usage, and an inadequate antibacterial performance in the context of adhesion-blocking coatings. Consequently, no specific methods or materials have been identified for such applications.

The anodic oxidation method was previously employed by adding fluorine onto the surface of a titanium alloy to inhibit bacterial adhesion and combat biofilm formation [15, 16]. Consequently, iodine, another halogen, has also been investigated in the same context. Polyvinyl pyrrolidone-iodine (PVP-I) possesses a broad-spectrum antibacterial activity, a high efficacy, rapid bactericidal effects, a low drug toxicity, minimal tissue irritation, an excellent tissue permeability, and a prolonged duration of action. As a result, it has found extensive applications in clinical and nursing fields [14]. In addition, Shirai et al. [17] demonstrated the antibacterial properties and biocompatibility of iodine-coated implants. Therefore, iodine could potentially be surface-coated onto orthopedic titanium implants to impede bacterial adhesion.

Here, anodic oxidation is employed to modify the surface of orthopedic titanium plates, followed by the electrophoretic deposition of iodine onto the modified surface. This approach aims to develop an orthopedic titanium implant with inherent antibacterial properties while also providing a novel strategy for preventing and treating the infections associated with orthopedic implants.

Methods

Modification of orthopedic titanium plates using TiO2 nanotube arrays by anodic oxidation

Initially, an orthopedic titanium plate (3.0 cm length, 1.0 cm width, 0.3 cm thickness, Tiā€“6Alā€“4V, Dabo Medical, China) was polished using metallographic sandpaper specimens with gradually decreasing coarseness values (from P1000 to P4000) until no visible scratches remained on the sample surface. Subsequently, the plate was cleaned thoroughly under running water, followed by treatment with absolute ethanol to remove any oil residues or pickling effects. The surface was then etched using a mixture of hydrofluoric and nitric acids (1:3 ratio) for 30 s to enhance the roughness. Subsequently, ultrasonic cleaning was conducted sequentially using absolute ethanol, acetone, and double-distilled water for 20 min each, prior to drying the plate for subsequent use. To prepare the electrolyte solution required for anodization, deionized water (25 mL) was added to a glycerol solution (250 mL), followed by the addition of ammonium fluoride crystals (1.25 g). After vigorous mixing, a 0.5 wt.% NH4F glycerol electrolyte solution was obtained. During anodization, a magnet was placed inside the beaker containing the electrolyte solution for magnetic agitation. The pretreated titanium plate served as the anode and was connected to a power source (WYK-6005K DC power supply, DCSOON, Shenzhen, China) via an electrode line. A platinum plate (3.0 cm length, 1.0 cm width, 0.1 cm thickness) acted as the cathode and was connected via another electrode line. The electrodes were positioned parallel to one another and 2 cm apart. The temperature was set at 25 ā„ƒ, the stirrer speed was 130 rpm, the applied voltage was fixed at 70 V, and the duration of the anodization process was 10 h. Upon complete anodization, the samples were rinsed with deionized water, subjected to sonication for 10 min, and thoroughly dried prior to further use.

Growth of the TiO2 nanotubes on the titanium plate surface

The growth parameters of the titanium dioxide nanotubes on the surfaces of the titanium plates were observed by electron microscopy.

Electrodeposition on the Ti plate for iodine doping

A 4,000-ppm aqueous solution of PVP-I (1 ppmā€‰=ā€‰1 mg/kgā€‰=ā€‰1 mg/L) was prepared using distilled water (100 mL) and solid PVP-I powder (400 mg). The cathode consisted of a platinum plate (3 cm length, 1 cm width, 0.1 cm thickness), while the anode consisted of a TiO2 nanotube-deposited titanium plate, which was prepared as described above. After applying a voltage of 200 V for 30 min using a DC power supply (WYK-6005K DC power supply, DCSOON, Shenzhen, China), the titanium plate was coated with iodine-containing TiO2 nanotubes and cleaned with distilled water for 10 min prior to drying to obtain the desired iodine-doped TiO2 nanotube-coated titanium plate. The titanium plate was characterized using scanning electron microscopy (SEM), and the surface iodine content was determined using X-ray fluorescence spectrometry (Philips Company, Netherlands) and energy-dispersive spectrometer (Philips Company, Netherlands). FigureĀ 1 illustrates the surface preparation of the titanium plate.

Fig. 1
figure 1

Technological pathway. Preparation of the iodine-doped TiO2 nanotube-coated titanium plates

In vitro antibacterial evaluation

Ten untreated titanium plates were used as control samples (Ti group), 10 TiO2 nanotube-coated titanium plates were classified as the TiO2 group, and 10 iodine-doped TiO2 nanotube-coated Ti plates were classified as iodine-doped TiO2 nanotube coating group (I-TIO2 group). All titanium plates were sterilized by fumigation with ethylene oxide. The bacterial suspension was prepared using a standard Staphylococcus aureus strain (ATCC25923) for which a turbidimeter with a scale of 0.5 was used to 1 mL of 1.5ā€‰Ć—ā€‰108 CFU/mL bacterial suspension. Subsequently, an aliquot (1 mL) of this suspension was diluted with sterilized tryptic soy broth to give a concentration of 1.5ā€‰Ć—ā€‰106 CFU/mL. Bacterial inoculation was then carried out by adding the prepared bacterial suspension (30 mL) to the sterilized titanium plate in a sterile culture cup. After incubation at 37 Ā°C for 6 h, the plate was slowly removed from the culture cup and rinsed with phosphate-buffered saline (PBS, 5 mL) to remove any planktonic bacteria present on the surface. Subsequently, the titanium plate was transferred to a new sterile culture cup, and sterile saline (5 mL) was added to immerse the titanium plates. The immersed wire was placed in an ultrasonic shaker and then diluted 10,000 times. An aliquot (100 Ī¼L) of the solution was then spread over a nutrient agar medium plate (Qingdao Hope Bio, China) and cultured at 37 Ā°C for 24 h prior to counting the colonies.

Iodine sustained-release test

The iodine-doped titanium plates were maintained in a physiological saline solution at 37 Ā°C, with the iodine content being assessed after 2 weeks and 1 year.

Statistical analysis

Statistical analysis was performed using SPSS23 software (IBM, NY, USA). Analysis of variance (ANOVA) was conducted for each group after counting the colony-forming units (CFUs), and the least significant difference (LSD) test was used for pairwise comparisons. The significance level was set at 0.05, with Pā€‰<ā€‰0.05 being considered statistically significant.

Results

Structural characterization of the TiO2 nanotube arrays on the Ti plates

As shown in the left-hand image of Fig.Ā 2, the oxide layer on the surface of the polished titanium Kirschner wire was smooth, without any evidence of any scratches. In addition, the TiO2-coated titanium plate prepared by anodic oxidation exhibited a light blue appearance along with a smooth surface (Fig.Ā 2, right-hand image).

Fig. 2
figure 2

Visual characteristics of the titanium plate. The titanium plate after grinding and pretreatment (left) and the titanium plate bearing TiO2 nanotubes after anodization (right)

The characteristics of TiO2 nanotube growth were evaluated on the surface of the titanium plate using SEM. Under a controlled voltage of 70 V in the presence of 0.50 wt.% NH4F in the glycerol system, the nanotubes exhibited outward growth and gradual thickening until reaching maturity and stabilizing after 10 h. As shown in Fig.Ā 3, following anodization for 10 h, a 4.19-Ī¼m-thick layer of nanotubes developed on the surface, with diameters ranging from 210 to 240 nm.

Fig. 3
figure 3

SEM images of TiO2 nanotube arrays. SEM observations of the growth of TiO2 nanotube arrays on the titanium plate surface after anodization for 10 h. Left: SEM surface view structure of titanium plate surface without anodization (Ɨ5000ā€‰magnification). Middle: SEM surface view structure of the TiO2 nanotube array on the titanium plate surface (Ɨ5000ā€‰magnification). Right: SEM image showing the longitudinal structure of the TiO2 nanotube array on the titanium plate surface (Ɨ5000ā€‰magnification)

The changes in the TiO2 nanotube array arrangement on the titanium surface were subsequently investigated upon adjusting the working voltage employed during the anodization method. Using a working voltage of approximately 40 V, nanotube growth was uneven, and nanotubes with diameters of ~ 140 nm were obtained. Upon increasing the working voltage to 70 V, the nanotubes grew uniformly, and their diameters were increased to 240 nm. Although the nanotube diameter increased further to 310 nm at 90 V, their distribution began to appear uneven, and partial collapse was observed by SEM imaging.

The influence of the NH4F concentration on the TiO2 nanotube array was also examined. Using a concentration of 0.30 wt.% NH4F glycerol, the nanotube structures failed to form. However, upon increasing the concentration to 0.50 wt.%, an extremely uniform distribution of nanotubes (~ā€‰230 nm diameter) was observed. Upon further increase in the concentration to 0.8 wt.%, the uniformity of the nanotube distribution decreased, and the diameter also reduced toā€‰~ā€‰200 nm.

Structural characterization of the iodine-doped TiO2 nanotube arrays

After the electrophoretic deposition of iodine onto the TiO2 nanotube arrays, a light-yellow granular coating was observed on the surface of the titanium plate (Fig.Ā 4). This coating was roughly uniform with a stable structure, which was not affected by ultrasonic cleaning. In addition, some crystal structures were deposited on the surfaces of the nanotubes, which were tightly bound and distributed along the orifices and circumferences of the tubes (Fig.Ā 5). X-ray fluorescence spectrometry (XRF) and energy-dispersive spectrometer (EDS) confirmed the successful doping of iodine, wherein the iodine content on the surface of the titanium plate was 3.44 wt.%. As outlined in Figs.Ā 6, 7, and Table 1, the most abundant element was titanium (51.42 wt.%), followed by oxygen (29.93 wt.%), fluorine (7.14 wt.%), and iodine (3.44 wt.%). Iodine exhibits a uniform distribution across the surface.

Fig. 4
figure 4

Visual characteristics of iodine-doped TiO2 nanotube-coated titanium plate. Appearance of the iodine-doped TiO2 nanotube-coated titanium plate. After the electrophoretic deposition of iodine onto the TiO2 nanotube arrays, a light-yellow granular coating was observed on the surface of the titanium plate

Fig. 5
figure 5

SEM images of the iodine-doped TiO2 nanotube structure. Microscopic representation of the iodine-doped TiO2 nanotube structure. At 10,000-fold (left), 20,000-fold (middle), and 50,000-fold (right) magnifications, the microscopic representation of the iodine-doped TiO2 nanotube structure as observed by SEM imaging. Some crystal structures were deposited on the surfaces of the nanotubes, which were tightly bound and distributed along the orifices and circumferences of the tubes

Fig. 6
figure 6

Element content analysis. Elemental content map of the titanium plate surface as determined using XRF spectrometry. The elements on the surface of the titanium plate include titanium, oxygen, fluorine, iodine, carbon, aluminum, and vanadium

Fig. 7
figure 7

Element distribution analysis. Elemental electronic image of the titanium plate surface as determined using EDS. The elemental composition of the titanium plate surface follows a descending order: titanium, oxygen, fluorine, iodine, carbon, aluminum, and vanadium. Iodine exhibits a uniform distribution across the surface

Table 1 Elemental composition of the titanium plate surface

Antibacterial tests

The bacterial counts obtained for the nutrient agar medium plate of the control group (Ti group), the TiO2 group, and the I-TiO2 group were 95.30ā€‰Ā±ā€‰8.07, 76.50ā€‰Ā±ā€‰11.36, and 50.00ā€‰Ā±ā€‰10.50, respectively. In addition, all P values wereā€‰>ā€‰0.1, and the samples conformed to a normal distribution. Upon carrying out statistical ANOVA, the F value was determined to be 50.81, and the difference was statistically significant (Pā€‰=ā€‰7.04ā€‰Ć—ā€‰10āˆ’10,ā€‰<ā€‰0.05), as shown in Fig.Ā 8. Compared with the control group, the bacterial counts of the TiO2 and I-TiO2 groups decreased to varying degrees, and the differences were statistically significant (Pā€‰<ā€‰0.05). Moreover, compared with the TiO2 group, the bacterial count of the I-TiO2 group was significantly lower (Pā€‰<ā€‰0.05).

Fig. 8
figure 8

Statistical analysis. Comparison of the bacterial counts in the three experimental groups. Upon carrying out statistical ANOVA, the F value was determined to be 50.8139, and the difference was statistically significant (Pā€‰=ā€‰7.037ā€‰Ć—ā€‰10āˆ’10,ā€‰<ā€‰0.05). Compared with the Ti group, the bacterial counts of the TiO2 and I-TiO2 groups decreased to varying degrees, and the differences were statistically significant (Pā€‰<ā€‰0.05). Moreover, compared with the TiO2 group, the bacterial count of the I-TiO2 group was significantly lower (Pā€‰<ā€‰0.05)

Iodine sustained-release test

The gradual decrease in surface iodine content of the iodine-doped titanium plate was observed when stored in a saline environment at 37 ā„ƒ. After two weeks, the iodine element on the titanium plate decreased by approximately 20%, and this reduction escalated to 80% within a year.

Discussion

Titanium alloys are known to exhibit good biological characteristics and unique physical properties that meet the necessary clinical requirements. However, because titanium is a foreign substance and an inert metal, surface adhesion and aggregation of bacteria can occur, leading to refractory periprosthetic infection [18, 19]. At present, the surface modification and coating of titanium implants are the most used methods to impart antibacterial properties to such structures [12]. Bacterial adhesion is influenced by many factors such as physical and chemical characteristics, nanomorphology, wetness, and roughness of the material surface. For instance, Kunrath et al. found that the high roughness and hydrophilicity of the implant surface increased the bacterial adhesion of the surface [20, 21]. Meanwhile, our study lacks the determination of surface roughness and wettability of the iodine-doped titanium plates. Adjustments to surface wettability, roughness, and other characteristics may alter the antibacterial performance of the iodine-doped titanium plates, necessitating further experiments to confirm these findings. As a potential coating material, TiO2 nanotubes are known to generate stable film layers with orderly arrangements, porous structural arrays, and high surface areas. Previously, anodic oxidation has been widely used to prepare these nanotubes because of its simple and low cost process, in addition to its ability to generate highly ordered arrays and take part in strong bonding with the titanium matrix [22]. To date, many studies have shown that the use of different nanotube morphologies can induce osteogenic differentiation and bone mineralization of bone marrow mesenchymal stem cells, wherein the ability to induce osteogenesis varies according to the nanotube diameter [23]. In addition, the inhibitory effect of TiO2 nanotubes on bacterial adhesion occurs mainly through the generation of reactive oxygen species, which kill bacteria; however, a photocatalytic mechanism has also been reported [24, 25]. With these considerations in mind, anodization was used in the present study to prepare TiO2 nanotube arrays on the surface of a titanium plate. By continuously adjusting the voltage parameters, anodization time, and concentration of the NH4F glycerol system, an optimal voltage of 70 V was determined for application in a 0.5 wt.% NH4F in glycerol system over 10 h. Under these conditions, the obtained TiO2 nanotube array contained structures with diameters of 210ā€“240 nm and heights of 4.2 Ī¼m, which adopted a stable and ordered arrangement. Using SEM for morphology monitoring at different time periods, four stages of nanotube growth were identified, namely appearance, aggregation, growth, and maturation. By in vitro experiments, this modified structure exhibited a superior antibacterial activity compared to the unmodified titanium plate. Moreover, the nanotube thickness is responsible for determining the color of the nanotube coating [26], which in this case was blue.

Titanium nanocoatings prepared via the anodization oxidation approach are durable coatings that successfully block the titanium plate surface and inhibit bacterial adhesion. However, their antibacterial characteristics tend not to meet most clinical requirements. Thus, considering the drug-loading characteristics of nanotubes, the development of a safe and low-toxicity drug-loading structure was considered using these structures. For this purpose, the PVP-I complex was selected, wherein the bactericidal component is iodine. The bactericidal mechanism of iodine involves inhibition of the bacterial cell processes, the oxidation of nucleotides/amino acids and fats in the bacterial cell membrane, inhibition of the cytoplasmic enzymes of the respiratory chain, denaturation, and inactivation [27]. In vitro experiments have shown that iodine not only exhibits a wide range of antibacterial effects, but that it also antagonizes both pathogens and host inflammatory responses [28]. PVP-I has been used for decades for infection prevention [14], and it is one of the few agents that has been shown to be effective against bacteria, fungi, viruses, spores, and amoebic cysticercus in topical antibacterial experiments. Indeed, it has been demonstrated to kill a range of bacteria that are responsible for nosocomial infections, including methicillin-resistant Staphylococcus aureus (MRSA) [29, 30]. Thus, considering these characteristics, 3.44 wt.% iodine was doped onto the surfaces of the TiO2 nanotubes via the electrophoretic deposition method, as confirmed by elemental mapping and quantification. During the subsequent in vitro experiments, the antibacterial activity of the iodine-doped TiO2 nanotube-coated Ti plate was superior to that of the pure TiO2 nanotube-coated Ti plate. Previously, our group investigated the direct doping of iodine onto the surface of a titanium plate via the electrophoretic deposition method, wherein the iodine doping reached 14.48 wt.%. However, the antibacterial properties of the resulting material did not reflect this higher doping, indicating that the nanotubes also imparted a beneficial effect. Thus, subsequent experiments were carried out to increase the iodine content of the coating surface by increasing the PVP-I electrolyte concentration, altering the voltage, and prolonging the treatment time; however, the results were unsatisfactory. More specifically, altering the voltage and prolonging the electrophoresis time led to an increase in the nanotube thickness, an increase in the resistance, and a decrease in the working current, eventually leading to loss of the film structure and a reduced iodine content. Furthermore, the antibacterial experiment within this study was exclusively focused on Staphylococcus aureus for a duration of 24 h in vitro. Further investigation is required to ascertain whether altering bacterial strains and extending the antibacterial experiment time would have an impact on the antibacterial performance.

Importantly, the prepared iodine-doped TiO2 nanotube-coated structure is a combination of two modification modes on the surface of the titanium plate. Although antibacterial experiments have only been carried out in vitro thus far, it would be of interest to carry out in vivo experiments to determine whether the doping of iodine increases the toxic effects. For example, the release of iodine into the body could cause metabolic abnormalities related to the thyroid function. Previously, the V97 cell colony aggregation method was used to study the cytotoxicity of iodine-coated implants in vitro [31], and it was reported that, compared to stainless steel and titanium alloys, there was no specific difference in the number of cells growing on the culture dish of the iodine-coated implant, thereby suggesting that the toxic effect of iodine is low. Other studies have found that iodine does not cause changes in thyroid function in vivo, and a good safety profile was recorded in more than 20 patients [32, 33]. Moreover, the release cycle of iodine is a matter of concern. The iodine content was found to have decreased by 20% after two weeks, and byā€‰>ā€‰80% after one year. Since the incidence of implant-associated infection is concentrated in the period between surgery and wound healing, a period of two weeks can be considered a key marker. Thus, maintaining a high concentration of iodine on the surface of the titanium plate over this period should help prevent and treat acute infection after prosthesis implantation. Therefore, the iodine-loaded TiO2 nanotube-coated titanium plates should exhibit good safety prospects. Finally, there are still some shortcomings to the current study. For example, further experimentation is required to characterize the implant structure, including its surface roughness and wetness, and future studies should be focused on images related to the bacterial biofilm development, cellular and in vivo models, and biocompatibility evaluations.

Conclusions

In this study, a titanium dioxide nanotube coating was prepared on the surface of a titanium plate by anodic oxidation, and iodine doping was realized by electrophoretic deposition. The iodine-doped titanium dioxide nanotube-coated titanium plate, which was produced by combining the two surface modification methods, exhibited a stable film structure and good antibacterial properties against Staphylococcus aureus based on the 24-h in vitro antimicrobial activity test, providing a new theoretical basis for the research and development of anti-infection implants in orthopedics.

Availability of data and materials

The datasets used and analysis relevant to this study are available from the corresponding author upon reasonable request.

Abbreviations

BBF:

Bacterial biofilm

PVP-I:

Polyvinyl pyrrolidone-iodine

SEM:

Scanning electron microscopy

PBS:

Phosphate-buffered saline

ANOVA:

Analysis of variance

CFU:

Colony-forming unit

LSD:

Least significant difference

MRSA:

Methicillin-resistant Staphylococcus aureus

References

  1. Ridgeway S, Wilson J, Charlet A, Kafatos G, Pearson A, Coello R. Infection of the surgical site after arthroplasty of the hip. J Bone Joint Surg Br. 2005;87:844ā€“50.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  2. Fricka KB, Yep PJ, Donnelly PC, Mullen KJ, Wilson EJ, Hopper RH Jr, Engh CA Jr. Timing and factors associated with revision for infection after primary total knee arthroplasty based on American Joint Replacement Registry Data. J Arthroplasty. 2023;6(2):S308ā€“13.

    ArticleĀ  Google ScholarĀ 

  3. Shen J, Wei Z, Wang S, Wang X, Lin W, Liu L, Wang G. Treatment of infected bone defects with the induced membrane technique. Bone Joint Res. 2023;12(9):546ā€“58.

    ArticleĀ  PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

  4. Costerton JW, Stewart PS, Greenberg EP. Bacterial biofilms: A common cause of persistent infections. Science. 1999;284:1318ā€“22.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  5. Gristina AG, Dobbins JJ, Giammara B, Lewis JC, DeVries WC. Biomaterial-centered sepsis and the total artificial hearts: Microbial adhesion versus tissue integration. JAMA. 1988;259:870ā€“4.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  6. Donlan RM, Costerton JW. Biofilms: survival mechanisms of clinically relevant microorganisms. Clin Microbiol Rev. 2002;15:167ā€“93.

    ArticleĀ  CASĀ  PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

  7. Ahmadabadi HY, Yu K, Kizhakkedathu JN. Surface modification approaches for preventing implant-associated infections. Colloidal Surf B Biointerface. 2020;193:111116.

    ArticleĀ  CASĀ  Google ScholarĀ 

  8. Diez-Escudero A, Hailer NP. The role of silver coating in arthroplasty components. Bone Joint J. 2021;103:423ā€“9.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  9. Shao H, Zhang T, Gong Y, He Y. Silver-containing biomaterials for biomedical hard tissue implants. Adv Healthc Mater. 2023;10:e2300932.

    ArticleĀ  Google ScholarĀ 

  10. Osman N, Devnarain N, Omolo CA, Fasiku V, Jaglal Y, Govender T. Surface modification of nano-drug delivery systems for enhancing antibiotic delivery and activity. Wiley Interdiscip Rev Nanomed Nanobiotechnol. 2022;14:e1758.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  11. Schierholz JM, Rump AFE, Pulverer G, Beuth J. Anti-infective catheters: Novel strategies to prevent nosocomial infections in oncology. Anticancer Res. 1998;18:3629ā€“38.

    CASĀ  PubMedĀ  Google ScholarĀ 

  12. Chouirfa H, Bouloussa H, Migonney V, Falentin-DaudrĆ© C. Review of titanium surface modification techniques and coatings for antibacterial applications. Acta Biomater. 2019;83:37ā€“54.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  13. Filipović U, Dahmane RG, Ghannouchi S, Zore A, Bohinc K. Bacterial adhesion on orthopedic implants. Adv Colloid Interface Sci. 2020;283: 102228.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  14. Barreto R, Barrois B, Lambert J, Malhotra-Kumar S, Santos-Fernandes V, Monstrey S. Addressing the challenges in antisepsis: Focus on povidone iodine. Int J Antimicrob Agents. 2020;56: 106064.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  15. Perez-Jorge C, Arenas MA, Conde A, HernƔndez-Lopez JM, de Damborenea JJ, Fisher S, et al. Bacterial and fungal biofilm formation on anodized titanium alloys with fluorine. J Mater Sci Mater Med. 2017;28(1):8.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  16. Aguilera-Correa JJ, Mediero A, Conesa-Buendƭa FM, Conde A, Arenas MƁ, de-Damborenea JJ, et al. Microbiological and cellular evaluation of a fluorine-phosphorus-doped titanium alloy, a novel antibacterial and osteostimulatory biomaterial with potential applications in orthopedic surgery. Appl Environ Microbiol. 2019;85(2):e02271-e2318.

    ArticleĀ  CASĀ  PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

  17. Shirai T, Tsuchiya H, Terauchi R, Tsuchida S, Shimomura S, Kajino Y, Takahashi K. Iodine-supported implants in prevention and treatment of surgical site infections for compromised hosts: A prospective study. J Orthop Surg Res. 2023;18:388.

    ArticleĀ  PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

  18. Barfeie A, Wilson J, Rees J. Implant surface characteristics and their effect on osseointegration. Br Dent J. 2015;218:E9.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  19. Oliveira WF, Arruda IRS, Silva GMM, Machado G, Coelho LCBB, Correia MTS. Functionalization of titanium dioxide nanotubes with biomolecules for biomedical applications. Mater Sci Eng C Mater Biol Appl. 2017;81:597ā€“606.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  20. Kunrath MF, Monteiro MSG, Gupta S, Hubler R, de Oliveira SD. Influence of titanium and zirconia modified surfaces for rapid healing on adhesion and biofilm formation of Staphylococcus epidermidis. Arch Oral Biol. 2020;117:104824.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  21. Kunrath MF, Dos Santos RP, de Oliveira SD, Hubler R, Sesterheim P, Teixeira ER. Osteoblastic cell behavior and early bacterial adhesion on macro-, micro-, and nanostructured titanium surfaces for biomedical implant applications. Int J Oral Maxillofac Implants. 2020;35(4):773ā€“81.

    ArticleĀ  PubMedĀ  Google ScholarĀ 

  22. Li Y, Yang Y, Li R, Tang X, Guo D, Qing Y, et al. Enhanced antibacterial properties of orthopedic implants by titanium nanotube surface modification: a review of current techniques. Int J Nanomedicine. 2019;14:7217ā€“36.

    ArticleĀ  CASĀ  PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

  23. Kunrath MF, Diz FM, Magini R, GalƔrraga-Vinueza ME. Nanointeraction: The profound influence of nanostructured and nano-drug delivery biomedical implant surfaces on cell behavior. Adv Colloid Interface Sci. 2020;284:102265.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  24. Noman MT, Ashraf MA, Ali A. Synthesis and applications of Nano-TiO2: a review. Environ Sci Pollut Res. 2019;26:3262ā€“91.

    ArticleĀ  CASĀ  Google ScholarĀ 

  25. Faraji M, Mohaghegh N, Abedini A. Ternary composite of TiO2 nanotubes/Ti plates modified by g-C3N4 and SnO2 with enhanced photocatalytic activity for enhancing antibacterial and photocatalytic activity. J Photochem Photobiol B. 2018;178:124ā€“32.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  26. Wang X, Chen X, Zhang D, Chen J, Deng P, Zhong Z, et al. UV radiation cumulative recording based on amorphous TiO2 nanotubes. ACS Sens. 2019;4:2429ā€“34.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  27. Kanagalingam J, Feliciano R, Hah JH, Le TA, Lin JC. Practical use of povidone-iodine antiseptic in the maintenance of oral health and the prevention and treatment of common oropharyngeal infections. Int J Clin Pract. 2015;69:1247ā€“56.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  28. Beukelman CJ, van den Berg AJ, Hoekstra MJ, Reimer K, Mueller S. Anti-inflammatory properties of a liposomal hydrogel with povidone-iodine (Repithel) for wound healing in vitro. Burns. 2008;34:845ā€“55.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  29. Lepelletier D, Maillard JY, Pozzetto B, Simon A. Povidone iodine: Properties, mechanisms of action, and role in infection control and Staphylococcus aureus decolonization. Antimicrob Agents Chemother. 2020;64:e00682-e720.

    ArticleĀ  CASĀ  PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

  30. Capriotti K, Pelletier J, Barone S, Capriotti J. Efficacy of dilute povidone-iodine against multidrug-resistant bacterial biofilms, fungal biofilms, and fungal spores. Clin Res Dermatol. 2018;5:1ā€“5.

    ArticleĀ  Google ScholarĀ 

  31. Shirai T, Shimizu T, Ohtani K, Zen Y, Takaya M, Tsuchiya H. Antibacterial iodine-supported titanium implants. Acta Biomater. 2011;7:1928ā€“33.

    ArticleĀ  CASĀ  PubMedĀ  Google ScholarĀ 

  32. Ueoka K, Kabata T, Tokoro M, Kajino Y, Inoue D, Takagi T, et al. Antibacterial activity in iodine-coated implants under conditions of iodine loss: study in a rat model plus in vitro analysis. Clin Orthop Relat Res. 2021;479:1613ā€“23.

    ArticleĀ  PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

  33. Shirai T, Tsuchiya H, Terauchi R, Tsuchida S, Shimomura S, Kajino Y, et al. Iodine-supported implants in prevention and treatment of surgical site infections for compromised hosts: A prospective study. J Orthop Surg Res. 2023;18:388.

    ArticleĀ  PubMedĀ  PubMed CentralĀ  Google ScholarĀ 

Download references

Acknowledgements

We would like to thank Editage (www.editage.cn) for English language editing.

Funding

This research was funded by the Hospital-Level Project of the 900th Hospital of the Joint Logistics Support Force of the PLA (grant numbers 2021JQ06, 2022MS03, and 2022Y0402).

Author information

Authors and Affiliations

Authors

Contributions

WW contributed to conceptualization; JC was involved in funding acquisition; QC contributed to supervision; XH and SL were involved in visualization; XY contributed to writingā€”original draft; and NC was involved in writingā€”review and editing. All authors have read and agreed to the published version of the manuscript.

Corresponding authors

Correspondence to Wan-Ming Wang or Jin-Shui Chen.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

The authors declare no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Yang, X., Chen, NF., Huang, XL. et al. Iodine-doped TiO2 nanotube coatings: a technique for enhancing the antimicrobial properties of titanium surfaces against Staphylococcus aureus. J Orthop Surg Res 18, 854 (2023). https://doi.org/10.1186/s13018-023-04354-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13018-023-04354-8

Keywords