The effectiveness of virtual reality, augmented reality, and mixed reality training in total hip arthroplasty: a systematic review and meta-analysis

Abstract

Background

Extended reality (XR), including virtual reality (VR), augmented reality (AR), and mixed reality (MR), has been used in the training of total hip arthroplasty (THA). This study aims to examine the effectiveness of XR training in THA.

Methods

In this systematic review and meta-analysis, we searched PubMed (MEDLINE), EMBASE (OVID), Cochrane Central Register of Controlled Trials (CENTRAL), Web of Science, and clinicaltrials.gov from inception to September 2022 for eligible studies. The Review Manager 5.4 software was applied to compare accuracy of inclination and anteversion, and surgical duration between XR training and conventional methods.

Results

We identified 213 articles, of which 4 randomized clinical trials and 1 prospective controlled study including 106 participants met inclusion criteria. The pooled data indicated the XR training had better accuracy of inclination and shorter surgical duration than conventional methods (MD = −2.07, 95% CI [− 4.02 to −0.11], P = 0.04; SMD = −1.30, 95% CI [− 2.01 to −0.60], P = 0.0003), but the accuracy of anteversion was similar in the two groups.

Conclusions

This systematic review and meta-analysis found XR training had better accuracy of inclination and shorter surgical duration than conventional methods in THA, but the accuracy of anteversion was similar. Based on the pooled results, we suggested that XR training can better improve trainees’ surgical skills than conventional methods in THA.

Introduction

Total hip arthroplasty (THA) is an effective method for the management of severe hip joint disorders [1]. As the incidence of osteoarthritis and other degenerative diseases affecting the bones and joints increases, so does the need for THA [2]. The number of THAs performed annually in the USA is projected to increase from 330,000 in 2010 to 635,000 by 2030 [3], emphasising the importance of prolonging the longevity of implants and reducing the risk of revision through reproducible surgery. Optimal anteversion and inclination angles of the acetabular cup are essential for a successful THA [4,5,6]. The interaction between acetabular cup position and femoral stem anteversion contributes to the functional range of hip motion, while preventing intra-articular and extra-articular impingements, instability, and polyethylene wear [4,5,6,7]. Malposition of the acetabular component increases the risk of dislocation, impingement, pelvic osteolysis, acetabular migration, and acetabular lining wear [8, 9]. Historically, the “safe zone” of acetabular component orientation described by Lewinnek et al. [10] to minimize dislocation risk has been used as a guide; however, the ideal acetabular component position is unknown [11].

THA is a complex operation that generally requires a long learning curve [12, 13]. Low-volume or junior surgeons [14] are more likely to malposition implants outside of the safe zone [10]. Safe, standardized, and effective surgical training for THA is therefore imperative. At present, the commonly used training methods are reading technique manuals, using instruments on low-fidelity synthetic bone models, and observing surgery, and the most realistic environment is the simulation of human cadaver joints, and we call these methods conventional methods. Worldwide, there are reduced surgical training opportunities due to changes in work-hour limits, service reconfiguration, and a focus on patient safety and hospital productivity [15].

Recently, increasing interest has been paid to virtual reality (VR), augmented reality (AR), and new mixed reality (MR), which include both AR and VR, in the medical education world, particularly for anatomy teaching and resident surgical training [16,17,18]. VR technology generally uses a headset, blocking out visual stimulus from the real world. AR allows users to see the real world, but overlays virtual elements. MR combines the two, including aspects of both the real and virtual world [19, 20]. Extended reality (XR) is the umbrella term that refers to these three different types of technology [21]. Combined with the continued rapid advancements in graphic processor technology and interest from software developers to create immersive surgical skill training simulations, XR users can practice surgical skills in an interactive and risk-free virtual environment. Several studies have shown that XR training was substantially more effective than conventional methods in improving the surgical performance of trainees for THA [22, 23]. XR training resulted in clinically relevant improvements in overall performance, better completion rate of the key surgical steps, more accurate implant position, and faster surgery. But some scholars do not agree with these results [24, 25].

To our knowledge, no systematic review and meta-analysis has explored the effectiveness of XR training in THA. Thus, this systematic review and meta-analysis was designed to compare XR training versus conventional methods in THA in terms of implant positioning, and surgical duration, in order to gain some theoretical insights that may guide clinical practice.

Methods

We conducted a systematic review and meta-analysis in accordance with the 2020 version of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA 2020) [26]. The study was registered on the International Prospective Register of Systematic Reviews (PROSPERO) (CRD42022366865).

Search strategy and selection criteria

In an academic medical setting, we searched electronic databases to identify relevant studies from inception to September 2022, including PubMed (MEDLINE), EMBASE (OVID), Cochrane Central Register of Controlled Trials (CENTRAL), Web of Science, and clinicaltrials.gov. Search terms included: (virtual reality OR augmented reality OR mixed reality) AND total hip arthroplasty. To achieve the highest sensitivity, we used a combination of keywords and indexed terms (e.g., PubMed Medical Subject Headings). Complete search algorithms for each database are available in the Additional file 1. We also reviewed the reference lists of eligible studies and previous evidence summaries to identify additional literature. Because our aim was to be as comprehensive as possible in the systematic review, we did not place time or publication status limits to the search except for restriction to the English language.

The criteria for inclusion were research articles studying virtual reality, augmented reality, and mixed reality training compared to conventional methods in THA and reporting on the accuracy of implant placement and surgical duration. Studies were excluded if they were technical notes, letters to the editor, expert opinions, review articles, meta-analyses, scientific conference abstracts, and case reports. Our primary search objective addressed the PICO (population, intervention, comparator and outcomes) question. The PICO criteria for study inclusion are as shown in Table 1. Two reviewers (SS and RW) working independently considered the potential eligibility of each of the abstracts generated by the search strategy. The combination of EndNote software (version X9, Thomson Corporation, Stanford, USA) and manual screening was carried out to remove duplicates. Full-text articles were obtained unless both reviewers decided that an abstract was ineligible. Each full-text report was assessed independently for final study inclusion. Disagreement was resolved through discussion and consensus between the reviewers (SS and RW).

Table 1 ‘Population, Intervention, Comparator, Outcomes’ (PICO) criteria for eligibility

Data extraction and quality assessment

Two reviewers (SS and RW) independently extracted data from each article using a predefined data extraction form. Any disagreements between them were solved by a discussion (SS and RW). The included studies were evaluated for the authors, year of publication, country, study design, the type of XR, details of learners, the accuracy of inclination and anteversion, and surgical duration. In addition, the main conclusion from each study was also recorded. If data were not presented in the original article, corresponding authors were contacted to acquire the missing data, although no responses were received.

Two reviewers (SS and RW) evaluated the quality of included studies independently, utilizing the version 2 of the Risk of Bias tool of the Cochrane Library (RoB 2) [27]. The risk of bias tool comprised seven elements from five domains (selection, reporting, performance, attrition, and other), and each of these items can be judged as low, unclear, and high risk. Disagreement was resolved through discussion and consensus between the reviewers (SS and RW).

Statistical analysis

Data were pooled and analyzed using the Review Manager software (version 5.4, Cochrane Collaboration, Oxford, UK). A P-value of < 0.05 was considered significant. For continuous data, the mean difference (MD) along with the 95% confidence interval (CI) was used to perform analysis, including the accuracy of inclination and anteversion. If different measurement methods or units were used for the same index and the mean values were significantly different, standardized mean difference (SMD) with 95% CI was used, such as surgical duration. One study [28] used different methods to measure the surgical duration. I2 statistic was used to assess the heterogeneity, and significant heterogeneity was identified as I2 > 50% and P < 0.10. The random-effect or fixed-effect model was selected depending on the heterogeneity of the included studies. When significant heterogeneity (I2 > 50%; P < 0.10) occurred, random-effect model was used and if not, a fixed-effect model was selected. In case of significant heterogeneity, sensitivity analysis was conducted to evaluate the influence of every single study on the meta-analysis outcome by excluding studies one by one. Forest plots were used to present the results of the individual studies and respective pooled estimates of effect size. Publication bias was estimated by a funnel plot and a publication bias was considered present if an asymmetry in the funnel plot was found. According to Egger et al. [29], the ability of funnel plots to detect this bias is limited when the number of included studies is small. Consequently, we ensure to provide the funnel plot as a supplementary file.

Results

Search findings

A total of 213 potentially relevant articles were extracted from the 5 electronic databases (Additional file 2). After deleting 83 duplicates, 111 irrelevant articles were excluded after their titles and abstracts were reviewed. We reviewed the remaining 19 full-text articles. We excluded another 14 articles for irrelevant content or incomplete data. Ultimately, 5 studies were included in this systematic review and meta-analysis. The detailed study selection process is shown in Fig. 1.

Fig. 1
figure 1

PRISMA (Preferred Reporting Items for Systemic Meta-Analyses) study selection flow diagram

Study characteristics and quality assessment

Overall, 5 studies, published from 2018 to 2020, met the inclusion requirements, including four randomized clinical trials (RCTs) [22, 24, 28, 30], and one prospective controlled study [31]. These studies involved 106 participants: 24 were medical students, 78 were residents, and 4 were expert hip surgeons. There were two studies performed in the USA and three studies in the UK. The types of XR used included VR and AR, without MR; conventional methods included traditional learning (lectures, textbooks, and videos), standard fluoroscopic technique, and training by an expert surgeon. Table 2 shows the characteristics of included studies.

Table 2 Characteristics of included studies

The result of the quality assessment was summarized in Fig. 2. The risk of bias was low for most of the domains. One study was rated to have high risk due to the absence of randomization, allocation concealment, and blinding [31]. Blinding of outcome assessment and incomplete outcome data in another study were reported high risk of bias [22].

Fig. 2
figure 2

Quality evaluation of included studies utilizing the Risk of Bias tool of the Cochrane Library. A Judgements of authors about each risk of bias item for each included study, B about each risk of bias item presented as percentages across all included studies

Accuracy of inclination and anteversion

Three of the included studies involving 68 participants reported the accuracy of inclination [28, 30, 31]. The random effects model was employed in the meta-analysis because of significant heterogeneity between the studies (P = 0.0002, I2 = 88%). The results showed that the XR training had better accuracy of inclination than conventional methods (MD = −4.65, 95% CI [− 8.92 to −0.37], P = 0.03) (Fig. 3A). When performing the sensitivity analysis, the heterogeneity came from one study [30]. As such, we performed analysis again after removing the study, and the pooled results also showed that the XR training had better accuracy of inclination than conventional methods (MD = −2.07, 95% CI [− 4.02 to −0.11], P = 0.04) (Fig. 3B). Also, three studies with 68 participants provided the accuracy of anteversion for analysis [28, 30, 31]. Because the data was significantly heterogeneous (P < 0.00001, I2 = 95%), the data analysis was performed with a random-effect model, showing no significant difference between the two groups (MD = −4.30, 95% CI [− 11.18 to 2.57], P = 0.22). The pooled result was shown in Fig. 4. We found that heterogeneity was still high after excluding studies one by one. We did not find the source of heterogeneity after intensive reading of three studies. One study [24] does not directly show the accuracy of inclination and anteversion, but uses orientation error to express. Orientation error is derived from the Pythagorean calculation by inclination error and anteversion error. There were no differences in orientation error between the expert surgeon-trained group and the AR group on the test using concealed pelvic tilt (6° ± 4°versus 7° ± 5°, P = 0.301).

Fig. 3
figure 3

A Forest plot to assess accuracy of inclination between two groups. B. Forest plot to assess accuracy of inclination after removing one study between two groups

Fig. 4
figure 4

Forest plot to assess accuracy of anteversion between two groups

Surgical duration

Three of the included studies involving 68 participants reported the surgical duration [28, 30, 31]. Since the heterogeneity between the studies was significant (P = 0.05, I2 = 67%), the random effects model was used for the meta-analysis. The results showed that the surgical duration was similar in the two groups (SMD = −0.86, 95% CI [− 1.89 to 0.17], P = 0.10), and the difference was not statistically significant (Fig. 5A). Because of the existence of significant heterogeneity, the sensitivity analysis was performed and indicated that the heterogeneity come from one study [31]. Therefore, we performed analysis again after removing the study; however, the pooled results (Fig. 5B) revealed the XR training had shorter surgical duration than conventional methods (SMD = −1.30, 95% CI [− 2.01 to −0.60], P = 0.0003).

Fig. 5
figure 5

A Forest plot to assess surgical duration between two groups. B Forest plot to assess surgical duration after removing one study between two groups

Here is a RCT [22], whose primary outcomes were improvement in test and cadaver THA scores, without directly measuring inclination, anteversion, or surgical duration. We included it in the review and found that VR training improves residents’ surgical skills but has no significant effect on medical knowledge between the VR and control groups. The most significant improvement was seen in technical skills.

Publication bias

To address publication bias, we created funnel plots for all analyses. The funnel plots of the accuracy of inclination and anteversion revealed asymmetry, indicating evidence of publication bias (Additional file 3). However, only three studies were included in the funnel plots; therefore, this result should be interpreted with caution.

Discussion

The principal finding of this systematic review and meta-analysis was that the XR training had better accuracy of inclination and shorter surgical duration than conventional methods in THA, but the accuracy of anteversion was similar in the two groups. One study [24] showed there were no differences in orientation error between the expert surgeon-trained group and the AR group. But orientation error is derived from the Pythagorean calculation by inclination error and anteversion error. Similar orientation error may be obtained by calculation of different inclination error and similar anteversion error. The results of this study may be consistent with our results. Unfortunately, we contacted the corresponding author to get the original data and did not get a response. To our knowledge, this is the first systematic review and meta-analysis to show the effectiveness of virtual reality, augmented reality, and mixed reality training in THA.

Surgery is a technical and learned skill, and reaching the expert level in surgery requires complex skills such as advanced pattern recognition, self-monitoring, and minimizing distractions [32]. If we think that about 75% of the important events in surgery are related to decision-making and 25% are related to dexterity, no simulation can replace the real surgical environment as a place to learn real surgical essentials from surgeons [22]. However, the operating room may not always be an ideal place to learn surgical skills, because of many problems related to patient safety, strict time limits, and so on [33]. Surgical technique training is a necessary process for real surgery in the operating room. Current orthopedic simulators cost approximately USD 100,000 [34], and most have yet to be validated to demonstrate the acquisition of skills by learners. The phantom hip and AR platform developed here cost approximately USD 10,000 [24]. Although this figure does not include institutional costs for software development, the platform is less expensive than currently available arthroscopic and open surgical platforms.

In addition, in the process of learning complex procedures, the attention of surgeons is always limited: early learners focus on learning technical skills and coordination of their movement, while training experts may demonstrate more intraoperative decision-making, planning, and avoiding adverse events based on their clinical experience [35]. This cannot be realized in the existing simulator. XR simulation can help early learners move toward automation outside the operating room as a supplement to conventional training, and help them focus on learning complex behaviors during the intraoperative experience [31]. Several studies in the field of general surgery have shown that skills learned in VR simulations can improve the performance of residents in the operating room [36, 37]. Also, VR and AR simulators have been validated to develop technical expertise for orthopedic fields, including drilling bone [38], and applying a femoral plate for fracture fixation [39]. As in our study, these have demonstrated that similar unsupervised training improves performance in novices. XR training can help trainees become familiar with the three-dimensional anatomy and instrumentation used to perform the operation without the labpratory space and instrument trays required for traditional simulation. Compared to learning from a video, XR simulation provides a more active learning experience. Although XR simulation does not provide real haptic feedback to trainees, it can vividly teach the flow and steps of surgery through pre-set procedural steps, which will be beneficial in the operating room environment.

At present, VR and AR simulators can help students to perform better [38,39,40]. But the data collection capabilities of them are limited. In the study, we did not find a training simulator based on MR. MR technology is a new type of digital holographic imaging technology that combines the advantages of VR and AR technology. By introducing real scene information into the virtual environment, it sets up an interactive feedback information loop between the virtual world, the real world, and users, to enhance the reality of user experience. Its key is to interact with the real world and obtain information promptly and to interact seamlessly with users of the real world and virtual models [20]. Perhaps in the near future, the development of MR training software can provide us with training in more complex surgical scenarios, which is suitable for higher-level surgeons. For example, it may be helpful to simulate periprosthetic fractures, revision hip arthroplasty, or hip dysplasia cases. Moreover, building decision-making questions into the software may help trainees learn more than procedural steps from the simulation.

The present study has some limitations. Firstly, there were only 5 studies included in this study with a total of 106 participants. The sample size of our study is small, which weakens the reliability of the study conclusion. Secondly, both RCTs and non-RCTs were included in our analysis due to lack of data, which adds to potential bias to this study. Thirdly, some of the studies did not contain sufficient information for pooled analyses. Although we tried to contact the authors for raw data, we were unable to do so. Finally, the language bias was inevitable since all included studies were published in English.

Conclusion

This systematic review and meta-analysis found XR training had better accuracy of inclination and shorter surgical duration than conventional methods in THA, but the accuracy of anteversion was similar. Based on the pooled results, we suggested that XR training can better improve trainees’ surgical skills than conventional methods in THA.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

XR:

Extended reality

VR:

Virtual reality

AR:

Augmented reality

MR:

Mixed reality

THA:

Total hip arthroplasty

PRISMA:

Preferred Reporting Items for Systematic Reviews and Meta-Analyses

MD:

Mean difference

OR:

Odds ratio

CI:

Confidence interval

RCT:

Randomized clinical trials

References

  1. Konan S, Duncan CP. Total hip arthroplasty in patients with neuromuscular imbalance. Bone Joint J. 2018;100-B(1 Supple A):17–21.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  2. Vina ER, Kwoh CK. Epidemiology of osteoarthritis: literature update. Curr Opin Rheumatol. 2018;30(2):160–7.

    Article  PubMed  PubMed Central  Google Scholar 

  3. Sloan M, Premkumar A, Sheth NP. Projected volume of primary total joint arthroplasty in the U.S., 2014 to 2030. J Bone Joint Surg Am. 2018;100(17):1455–60.

    Article  PubMed  Google Scholar 

  4. D’Lima DD, Urquhart AG, Buehler KO, Walker RH, Colwell CW Jr. The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. J Bone Joint Surg Am. 2000;82(3):315–21.

    Article  CAS  PubMed  Google Scholar 

  5. Murayama T, Ohnishi H, Mori T, Okazaki Y, Sujita K, Sakai A. A novel non-invasive mechanical technique of cup and stem placement and leg length adjustment in total hip arthroplasty for dysplastic hips. Int Orthop. 2015;39(6):1057–64.

    Article  PubMed  Google Scholar 

  6. Yamaguchi M, Akisue T, Bauer TW, Hashimoto Y. The spatial location of impingement in total hip arthroplasty. J Arthroplasty. 2000;15(3):305–13.

    Article  CAS  PubMed  Google Scholar 

  7. Widmer KH, Zurfluh B. Compliant positioning of total hip components for optimal range of motion. J Orthop Res. 2004;22(4):815–21.

    Article  PubMed  Google Scholar 

  8. Kennedy JG, Rogers WB, Soffe KE, Sullivan RJ, Griffen DG, Sheehan LJ. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J Arthroplasty. 1998;13(5):530–4.

    Article  CAS  PubMed  Google Scholar 

  9. Migliorini F, Eschweiler J, Trivellas A, Rath B, Driessen A, Tingart M, et al. Implant positioning among the surgical approaches for total hip arthroplasty: a Bayesian network meta-analysis. Arch Orthop Trauma Surg. 2020;140(8):1115–24.

    Article  PubMed  Google Scholar 

  10. Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60(2):217–20.

    Article  CAS  PubMed  Google Scholar 

  11. Snijders TE, Willemsen K, van Gaalen SM, Castelein RM, Weinans H, de Gast A. Lack of consensus on optimal acetabular cup orientation because of variation in assessment methods in total hip arthroplasty: a systematic review. Hip Int. 2019;29(1):41–50.

    Article  PubMed  Google Scholar 

  12. Nairn L, Gyemi L, Gouveia K, Ekhtiari S, Khanna V. The learning curve for the direct anterior total hip arthroplasty: a systematic review. Int Orthop. 2021;45(8):1971–82.

    Article  PubMed  Google Scholar 

  13. Cobb JP, Kannan V, Brust K, Thevendran G. Navigation reduces the learning curve in resurfacing total hip arthroplasty. Clin Orthop Relat Res. 2007;463:90–7.

    Article  PubMed  Google Scholar 

  14. Perfetti DC, Schwarzkopf R, Buckland AJ, Paulino CB, Vigdorchik JM. Prosthetic dislocation and revision after primary total hip arthroplasty in lumbar fusion patients: a propensity score matched-pair analysis. J Arthroplasty. 2017;32(5):1635–40.

    Article  PubMed  Google Scholar 

  15. Simpson C, Cottam H, Fitzgerald JE, Giddings CE. The European working time directive has a negative impact on surgical training in the UK. Surgeon. 2011;9(1):56–7.

    Article  PubMed  Google Scholar 

  16. Erolin C, Reid L, McDougall S. Using virtual reality to complement and enhance anatomy education. J Vis Commun Med. 2019;42(3):93–101.

    Article  PubMed  Google Scholar 

  17. Keating TC, Jacobs JJ. Augmented reality in orthopedic practice and education. Orthop Clin North Am. 2021;52(1):15–26.

    Article  PubMed  Google Scholar 

  18. Clarke E. Virtual reality simulation-the future of orthopaedic training? A systematic review and narrative analysis. Adv Simul (Lond). 2021;6(1):2.

    Article  PubMed  Google Scholar 

  19. Lei PF, Su SL, Kong LY, Wang CG, Zhong D, Hu YH. Mixed reality combined with three-dimensional printing technology in total hip arthroplasty: an updated review with a preliminary case presentation. Orthop Surg. 2019;11(5):914–20.

    Article  PubMed  PubMed Central  Google Scholar 

  20. Su S, Lei P, Wang C, Gao F, Zhong D, Hu Y. Mixed reality technology in total knee arthroplasty: an updated review with a preliminary case report. Front Surg. 2022;9: 804029.

    Article  PubMed  PubMed Central  Google Scholar 

  21. Kaplan AD, Cruit J, Endsley M, Beers SM, Sawyer BD, Hancock PA. The effects of virtual reality, augmented reality, and mixed reality as training enhancement methods: a meta-analysis. Hum Factors. 2021;63(4):706–26.

    Article  PubMed  Google Scholar 

  22. Hooper J, Tsiridis E, Feng JE, Schwarzkopf R, Waren D, Long WJ, et al. Virtual reality simulation facilitates resident training in total hip arthroplasty: a randomized controlled trial. J Arthroplasty. 2019;34(10):2278–83.

    Article  PubMed  Google Scholar 

  23. Ogawa H, Hasegawa S, Tsukada S, Matsubara M. A pilot study of augmented reality technology applied to the acetabular cup placement during total hip arthroplasty. J Arthroplasty. 2018;33(6):1833–7.

    Article  PubMed  Google Scholar 

  24. Logishetty K, Western L, Morgan R, Iranpour F, Cobb JP, Auvinet E. Can an augmented reality headset improve accuracy of acetabular cup orientation in simulated THA? A randomized trial. Clin Orthop Relat Res. 2019;477(5):1190–9.

    Article  PubMed  Google Scholar 

  25. Ogawa H, Kurosaka K, Sato A, Hirasawa N, Matsubara M, Tsukada S. Does an augmented reality-based portable navigation system improve the accuracy of acetabular component orientation during THA? A randomized controlled trial. Clin Orthop Relat Res. 2020;478(5):935–43.

    Article  PubMed  Google Scholar 

  26. Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021;372: n71.

    Article  PubMed  PubMed Central  Google Scholar 

  27. Sterne JAC, Savovic J, Page MJ, Elbers RG, Blencowe NS, Boutron I, et al. RoB 2: a revised tool for assessing risk of bias in randomised trials. BMJ. 2019;366: l4898.

    Article  PubMed  Google Scholar 

  28. Alexander C, Loeb AE, Fotouhi J, Navab N, Armand M, Khanuja HS. Augmented reality for acetabular component placement in direct anterior total hip arthroplasty. J Arthroplasty. 2020;35(6):1636-41.e3.

    Article  PubMed  Google Scholar 

  29. Egger M, Davey Smith G, Schneider M, Minder C. Bias in meta-analysis detected by a simple, graphical test. BMJ. 1997;315(7109):629–34.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  30. Logishetty K, Rudran B, Cobb JP. Virtual reality training improves trainee performance in total hip arthroplasty: a randomized controlled trial. Bone Joint J. 2019;101-B(12):1585–92.

    Article  PubMed  Google Scholar 

  31. Logishetty K, Gofton WT, Rudran B, Beaule PE, Cobb JP. Fully immersive virtual reality for total hip arthroplasty: objective measurement of skills and transfer of visuospatial performance after a competency-based simulation curriculum. J Bone Joint Surg. 2020;102(6):e27.

    Article  PubMed  Google Scholar 

  32. Kolozsvari NO, Feldman LS, Vassiliou MC, Demyttenaere S, Hoover ML. Sim one, do one, teach one: considerations in designing training curricula for surgical simulation. J Surg Educ. 2011;68(5):421–7.

    Article  PubMed  Google Scholar 

  33. Haluck RS, Krummel TM. Computers and virtual reality for surgical education in the 21st century. Arch Surg. 2000;135(7):786–92.

    Article  CAS  PubMed  Google Scholar 

  34. Mabrey JD, Reinig KD, Cannon WD. Virtual reality in orthopaedics: is it a reality? Clin Orthop Relat Res. 2010;468(10):2586–91.

    Article  PubMed  PubMed Central  Google Scholar 

  35. Gallagher AG, Satava RM, O’Sullivan GC. Attentional capacity: an essential aspect of surgeon performance. Ann Surg. 2015;261(3):e60–1.

    Article  PubMed  Google Scholar 

  36. Andreatta PB, Woodrum DT, Birkmeyer JD, Yellamanchilli RK, Doherty GM, Gauger PG, et al. Laparoscopic skills are improved with LapMentor training: results of a randomized, double-blinded study. Ann Surg. 2006;243(6):854–60 (discussion 60-3).

    Article  PubMed  PubMed Central  Google Scholar 

  37. Vera AM, Russo M, Mohsin A, Tsuda S. Augmented reality telementoring (ART) platform: a randomized controlled trial to assess the efficacy of a new surgical education technology. Surg Endosc. 2014;28(12):3467–72.

    Article  PubMed  Google Scholar 

  38. Vankipuram M, Kahol K, McLaren A, Panchanathan S. A virtual reality simulator for orthopedic basic skills: a design and validation study. J Biomed Inform. 2010;43(5):661–8.

    Article  PubMed  Google Scholar 

  39. Cecil J, Gupta A, Pirela-Cruz M. An advanced simulator for orthopedic surgical training. Int J Comput Assist Radiol Surg. 2018;13(2):305–19.

    Article  CAS  PubMed  Google Scholar 

  40. Negrillo-Cardenas J, Jimenez-Perez JR, Madeira J, Feito FR. A virtual reality simulator for training the surgical reduction of patient-specific supracondylar humerus fractures. Int J Comput Assist Radiol Surg. 2022;17(1):65–73.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

This study was supported by the National Natural Science Foundation of China (No. 81971160) and the Peking University Third Hospital Clinical Key Project Fund (No. BYSYZHKC2021106).

Author information

Authors and Affiliations

Authors

Contributions

FZ and SS conceived the original ideas of this manuscript. SS and RW screened out eligible studies separately. SS, RW, RZ, ZC and FZ discussed the controversial parts of literatures screening and quality evaluation. SS and RW completed data collection, analysis and finished the manuscript. FZ supervised the entire process and revised the manuscript. All authors have read and approved the manuscript.

Corresponding author

Correspondence to Fang Zhou.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

The authors report no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Additional file 1.

Database Search Algorithms.

Additional file 2.

213 potentially relevant articles.

Additional file 3.

Funnel plots to assess publication bias on the accuracy of inclination and anteversion.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Su, S., Wang, R., Zhou, R. et al. The effectiveness of virtual reality, augmented reality, and mixed reality training in total hip arthroplasty: a systematic review and meta-analysis. J Orthop Surg Res 18, 121 (2023). https://doi.org/10.1186/s13018-023-03604-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13018-023-03604-z

Keywords