Biological and functional evaluation of a novel pyrolytic carbon implant for the treatment of focal osteochondral defects in the medial femoral condyle: assessment in a canine model

Abstract

Background

Osteochondral defects continue to be a clinical treatment challenge, and when left untreated, may cause pain and functional impairment. Pyrolytic carbon is a unique isotropic biomaterial used in heart valve and small joint replacements due to its excellent wear properties and biocompatibility with bone and articular cartilage. Therefore, a proposed solution is to utilize a focal pyrolytic carbon hemiarthroplasty implant as an alternative resurfacing treatment strategy for isolated cartilage lesions.

Methods

A canine model (n = 9) was used to evaluate the in vivo histologic response and function of a pyrolytic carbon implant replacing a full-thickness osteochondral defect in the medial femoral condyle (MFC) of the knee. The gross appearance and histologic results were compared to an identical cobalt-chromium (Co-Cr) alloy implant placed in a defect in the contralateral MFC and evaluated up to 52 weeks.

Results

Extensive bone incorporation to the stem portion was observed for both implant types. The total mean histologic score for the cartilage of the MFC surrounding the pyrolytic carbon implants was significantly improved compared to that of the Co-Cr alloy implants at all evaluation periods (p < 0.05). Histologic grading and gross observations at 52 weeks for pyrolytic carbon implants were similar to those of Co-Cr alloy implants at 24 weeks. At 24 weeks, the mean total histologic score for Co-Cr alloy implants was 11.6 ± 0.7 (0–16 range point; 16 = normal appearance), while at 52 weeks, the mean total score for the pyrolytic carbon implants was 11.7 ± 1.3. Mean total histologic score of opposing medial tibia cartilage for the pyrolytic carbon implants was superior to that of the Co-Cr alloy group at all evaluation periods and significantly improved over the Co-Cr alloy implant group at 24 weeks (p = 0.001) and 52 weeks (p < 0.001).

Conclusions

Use of a pyrolytic carbon implant for reconstruction of a focal cartilage defect demonstrated effective implant fixation and superior in vivo response compared to an identical Co-Cr alloy implant.

Background

Osteochondral defects of the medial femoral condyle negatively impact functionality of the knee. Symptomatic lesions are generally painful and disabling, and can progress to osteoarthritis when left untreated. Not only is the repair tissue in a focal chondral or osteochondral defect inferior to normal articular cartilage but the presence of defects can also damage the opposing meniscus and tibial cartilage surface [1, 2].

Currently, there are several treatments available, which depending on the goal of the intervention, may be directed at relieving symptoms, regenerating tissue, or repairing the defect. Arthroscopic debridement and lavage alleviate symptoms but the long-term result for the lesion is poor [1, 36]. Abrasion chondroplasty, subchondral drilling, and microfracture have been shown to regenerate tissue with acceptable results, but the resulting fibrocartilage lacks the strength, organization, and biomechanics of normal articular cartilage [1, 7, 8]. Autologous chondrocyte implantation has produced good to excellent outcomes, but the multi-step procedure involves extensive rehabilitation, may not be appropriate for older or heavier patients, and also carries a risk of donor site morbidity [1, 9, 10]. In severe cases of osteoarthritis or in cases where other regenerative or revision techniques have failed, a total knee arthroplasty (TKA) is the most effective solution. However, total knee arthroplasty is a final resort for many patients due to likelihood of revision surgeries (usually within 15–20 years) and associated morbidity throughout the patient’s lifetime. For younger patients with TKAs, revision surgeries are more likely due to increased activity of younger patients which leads to greater implant wear and reduced implant lifespan [1114].

A proposed solution is a focal hemiarthroplasty implant, intended for use as an alternative resurfacing treatment strategy for isolated lesions in patients who are too young for TKAs [1] or not good candidates for regenerative procedures. Focal hemiarthroplasty devices using pyrolytic carbon [15], metal alloys [15, 16], polymer composites [17], and ceramic composites [18] have been investigated for a number of anatomical locations with varying results. Several previous studies have shown that even when the shape and design of the implant closely match the surface, the implant material properties may be detrimental to the opposing articular cartilage in the long-term due to differences in elastic modulus [15, 19, 20]. A mismatch in elastic properties contributes to higher stresses around the implant-bone interface, which leads to bone loss due to stress shielding, followed by bone resorption and implant loosening [21, 22].

Wear of articulating surfaces can also be a major limiting factor in arthroplasty and hemiarthroplasty. In the natural joint, surface-active phospholipids (SAPL) and their major component, dipalmitoylphosphatidylcholine (DPPC), have been found to possess remarkable capabilities in reducing friction and are excellent anti-wear agents even under high loads [23, 24]. Thus, researchers have identified that SAPL acts as the active boundary lubricant in both natural and artificial joints. A deficiency in SAPL, as in osteoarthritis, results in sticking of the articulating surfaces [25]. Purbach et al. [26] was the first to report on the presence of SAPL on artificial joints. Analysis of total hip replacement prostheses showed that sufficient SAPL was present to form oligolamellar layers on the bearing surfaces, suggesting that this layered structure of phospholipids acts similar to lamellated solid lubricants and protects the surface from wear.

Pyrolytic carbon has been shown to have superior qualities for use in partial and total joint replacements due, in part, to its similar elastic modulus to bone, which reduces stress shielding [27]. Pyrolytic carbon also has high strength, high fatigue resistance, and high wear resistance even when subjected to cyclic loads [2830]. Pyrolytic carbon has been shown to be biocompatible with both hard and soft tissues, which is important for minimizing host inflammatory response to an implanted medical device [29, 3133]. Studies have also shown that DPPC has a high affinity for pyrolytic carbon, indicating that SAPL will likely do the same [34, 35], thus effectively lubricating and reducing the friction between cartilage articulating against a pyrolytic carbon implant surface.

Experimental studies have been conducted using pyrolytic carbon as a hemiarthroplasty material. Cook et al. [28] evaluated degeneration of acetabular cartilage following implantation of proximal femoral hemiarthroplasties in dogs. The articulating surface of the femoral component was composed of either pyrolytic carbon, cobalt-chromium-molybdenum (Co-Cr-Mo) alloy, or titanium alloy. Results indicated that native acetabulum in articulation with pyrolytic carbon implants experienced a lesser degree of joint degeneration and there was significantly greater probability of cartilage survival with articulation against the pyrolytic carbon implant compared to the metal alloy implants. In an osteoarthritis model, Kawalec et al. [15] examined the histologic response to pyrolytic carbon and cobalt-chromium (Co-Cr) alloy hemiarthroplasty implants in the lateral femoral condyle of the knee in beagle dogs compared to an untreated cartilage control group. To simulate degeneration and loss of cartilage associated with osteoarthritis, Kawalec et al. created an osteochondral defect on the opposing lateral surface of the tibial plateau that articulated with a pyrolytic carbon device, a similar Co-Cr device, or the native condyle cartilage. Results showed no evidence of adverse inflammatory response, and fibrocartilage regeneration in 86% of knees treated with the carbon implants but only in 25% of metal implants. Improved fibrocartilage regeneration was attributed to the more “normal” biomechanical condition of the bone-carbon articulation than the bone-metal articulation.

The objective of this study was to use a canine model to evaluate the in vivo histologic response and function of a pyrolytic carbon implant in the medial femoral condyle of the knee and to compare the results to those obtained using an identical Co-Cr alloy implant.

Methods

Test devices

The device used in this study was a weight-bearing, cementless, single-component articular implant fabricated from either pyrolytic carbon or Co-Cr alloy and designed for implantation in the medial femoral condyle of the study animals (Fig. 1). The devices had an articulating surface with a 6-mm diameter and 11-mm radius of curvature. The stem was tapered with a series of four grooves, and the total height of the device was 12.35 mm. The pyrolytic carbon implants were machined from graphite with a pyrolytic carbon coating applied in a fluidized bed reactor. The implant’s stem surface had the as-deposited pyrolytic carbon material, while the articulating surfaces were polished to less than 2 μin. The articulating surfaces of the Co-Cr alloy implants were also polished to less than 2 μin. and the stem portion had a grit-blasted surface. The choice of a Co-Cr alloy analogous implant to the pyrocarbon implant was made based on currently available similarly functioning clinical implants such as the Co-Cr alloy HemiCAP device (Arthrosurface Inc., Franklin, MA) and the characterization of Co-Cr as a control articular implant in the literature in this application [15, 16] and in a similar articular joint application [28].

Fig. 1
figure 1

Pyrolytic carbon (left) and Co-Cr alloy (right) implant devices

Experimental design

Nine adult male beagle dogs, 1.6 ± 0.1 years of age, were used in the study (12.8 ± 2.2 kg). The study was undertaken after receiving approval from the In-Life Facility’s IACUC committee for all animal care and procedures. The animals were assigned to the following evaluation periods: 12 weeks post-surgery (n = 3), 24 weeks post-surgery (n = 3), and 52 weeks post-surgery (n = 3).

Surgical procedure and radiographic evaluation

All animals underwent bilateral implantation of the devices in the medial femoral condyle (pyrolytic carbon in one knee and Co-Cr alloy in the other, Fig. 2). Under sterile conditions, the medial capsule of the knee joint was approached through a median parapatellar incision. The medial retinaculum was partially released to dislocate the patella and the knee flexed to expose the medial femoral condyle. After exposure, a tapered defect representative of a grade IV cartilage lesion was produced using a series of custom guides and drills. The implant was then seated into the surgically created osteochondral defect site, using custom insertion instruments to ensure device alignment and surface continuity of the implant and articular surface. Anterior-posterior (AP) and lateral radiographs of the joint were taken immediately before and after surgery and at 6, 12, 24, and 52 weeks postoperative. Animals received tramadol (Ultram, 25 mg/dog, BID, oral) from day 1 to 5 (day 0 = surgical day) for management of postoperative pain. Animals received buprenorphine (0.01 mg/kg, intramuscular or subcutaneous (SC)) as deemed appropriate by the attending veterinarian to control moderate to severe pain. Acepromazine (0.2 mg/kg, SC) was administered as needed to minimize distress and improve anesthetic recovery.

Fig. 2
figure 2

Inter-operative photograph of placement of pyrolytic carbon (a) and Co-Cr (b) implants in the medial condyle

Lameness evaluation

A single, blinded observer recorded the extent of lameness to each knee joint using a numerical grading scale modified from Paradis et al. [36]. A lameness score of 0 was given if the animal could stand, walk, and trot normally; 1, if they stood normally and had a slight algetic gait; 2, if they stood abnormally and had a slight algetic gait; 3, if they stood normally and had an evident algetic gait; and 4, if they stood abnormally and had an evident algetic gait. Evaluations were performed once every 3 days during the first three postoperative weeks and then once at each radiograph interval (6, 12, 24, and 52 weeks postoperative).

Gross necropsy

Immediately following sacrifice, knee joints were harvested and contact radiographs taken. Harvested joints were grossly assessed for observations of the articular surfaces and surrounding cartilage, meniscus, and synovial joint tissues, as well as any discoloration or degenerative changes of the surrounding cartilage and discoloration of the synovial fluid.

Histology of medial femoral condyle cartilage and observation of bone-implant interface

Following gross evaluation, specimens for histology were fixed in 10% formalin and dehydrated in graduated ethyl alcohol solutions. Specimens were then embedded in methyl methacrylate monomer, allowed to polymerize, and sectioned in the sagittal plane central to the implant’s long axis. Three centermost ground sections relative to the condyles were obtained, mounted, and ground/polished to approximately 50 μm thick. Sections were stained with Paragon. Microradiographs of the final sections were made using high-resolution Faxitron film (Industrex, Carestream). Undecalcified histologic sections were assessed using a semi-quantitative grading scale (Table 1), adapted from histologic assessments made by Kirker-Head et al. [16]. The percentages of bone contact, soft tissue contact, and void space contact with the implant were measured via digital images taken at ×2 (Nikon DXM1200) and image analysis software (Image-Pro Plus, Media Cybernetics).

Table 1 Histology grading scale (modified from Kirker-Head et al. [16]) used in evaluation of medial femoral condyle cartilage

Tibial articular cartilage evaluation

Medial and lateral tibial plateaus with intact menisci were collected and processed using decalcified paraffin-embedded techniques. Each specimen was sectioned into medial, central, and lateral blocks. From each block, three serial sections (5 μm thick) were obtained and stained with H&E, toluidine blue, and safranin O/fast green. Medial sections were examined using a modified ICRS-Histological Visual Scale [37], which was modified to reflect changes to existing hyaline cartilage by the presence of an articulating implant (Table 2). Lateral sections were observed as comparative controls for cartilage and staining.

Table 2 Histology grading scale (modified from Mainil-Varlet et al. [37]) used in evaluation of medial menisco-tibial articulating tissues

Statistical methods

The pyrolytic carbon and Co-Cr alloy devices were evaluated as pair-wise, within-animal comparisons. Descriptive statistics of histologic data were calculated. All quantitative data were initially screened for statistical outliers, defined as data points with z-scores of 3.0 or greater. Analysis of variance (ANOVA) was used to determine the effect of the experimental group (pyrolytic carbon and Co-Cr alloy) and postoperative time (12, 24, and 52 weeks). Non-parametric ANOVA was used to determine the effect of the experimental group and postoperative time on the histologic scores (Kruskal-Wallis test [38]). Significance (*) was defined as p ≤ 0.05. Data are presented as mean ± standard deviation.

Results

Surgical procedure, lameness evaluation, and radiographic evaluation

All animals tolerated the procedures well, had uneventful recoveries, and remained in good health until time of sacrifice. Within 4 weeks postoperative, all animals were ambulatory without evidence of lameness or impairment, and had normal stance bilaterally without evidence of non-weight bearing or pain during walking. Lameness scores did not exceed a grade of 2 (generally noted bilaterally), and evidence of slight lameness did not persist beyond week 3. One animal had three occurrences of right hindlimb lameness (Co-Cr alloy implant) at 14, 17, and 25 days postoperative, in which the contralateral hindlimb (pyrolytic carbon implant) was normal.

Review of postoperative radiographs showed adequate placement of all implants (Fig. 3). There was no radiographic evidence of loosening of the implants during the course of this study. Radiolucency around the pyrolytic carbon implant was the result of the radiolucent pyrolytic carbon coating thickness, and this was accounted for in the observations.

Fig. 3
figure 3

Postoperative radiographs: pyrolytic carbon (top) and Co-Cr (bottom) implants at 12 weeks (a, d), 24 weeks (b, e), and 52 weeks (c, f)

Gross necropsy

At 12 weeks, gross observations (Fig. 4) of the pyrolytic carbon implanted knees showed no evidence of articular cartilage damage or color change; no joint capsule hypertrophy, osteophyte formation, or meniscal changes related to the implant; and normal appearance of the synovial fluid. Gross observations of the Co-Cr alloy implanted knees showed no evidence of articular cartilage damage, one instance of opaque articular cartilage, two instances of joint capsule hypertrophy, one instance of osteophyte formation, and one instance of mild degeneration/streaking and thin, translucent appearance of the medial meniscus.

Fig. 4
figure 4

Gross appearance of pyrolytic carbon (left) and Co-Cr alloy (right) implants at 12 weeks (a, b), 24 weeks (c, d), and 52 weeks (e, f)

At 24 weeks, observation of the pyrolytic carbon implanted knees revealed one knee with moderate degeneration of the cartilage and minimal changes to the medial tibial plateau. For the Co-Cr alloy implanted knees, two had minimal fibrillation/degeneration of the cartilage on both the medial femoral condyle and medial tibial plateau surfaces, one with slight opacity changes in the articular cartilage, one with a thickened joint capsule, one osteophyte presence, one medial meniscus with mild degeneration/streaking, and no finding related to the gross appearance of the ligaments.

At 52 weeks, two of the pyrolytic carbon implanted knees had moderate degenerative changes of the cartilage on the medial femoral condyle with no changes on the medial tibial plateau surfaces and both had slight opacity changes to the articular cartilage. An osteophyte was present on one knee with mild streaking on the rim of one medial meniscus. All ligaments appeared normal. For the Co-Cr alloy implanted knees, one knee had moderate fibrillation/degeneration of the cartilage on both the medial femoral condyle and the medial tibial plateau surfaces and the articular cartilage was discolored. One knee had a thickened joint capsule with hypertrophy of the lateral collateral ligaments, two knees had condylar osteophytes, and one knee had a medial meniscus with evidence of moderate degeneration and a thinned, translucent appearance.

Histology of medial femoral condyle cartilage and observation of bone-implant interface

Histologic grading of the medial femoral condyle tissues showed that no significant inflammatory response was observed to either implant material at any evaluation period. The scores for the amount of cartilage flow over the implant (Fig. 5a) and the degree of implant-bone apposition (Fig. 5b) showed no significant differences between the two groups at any time point (Fig. 6). The mean implant-cartilage interface score for the pyrolytic carbon group was significantly improved compared to that of the Co-Cr alloy group at all time points (p < 0.05) (Fig. 5c). Histologic sections at 52 weeks postoperative demonstrated excellent maintenance of the host cartilage-implant interface with minimal cellular and mechanical changes present for the pyrolytic carbon implant, while significant cellular changes with loss of matrix staining was observed for the Co-Cr alloy implant at and near the host cartilage-implant interface (Fig. 7). The mean cartilage morphology score for the pyrolytic carbon group was significantly improved compared to that of the Co-Cr alloy group at 24 and 52 weeks (Fig. 5d). Overall, the mean total score of the pyrolytic carbon group was significantly improved over that of the Co-Cr alloy group at all evaluation periods (p < 0.05) (Fig. 8). Histologic grading and observations at 52 weeks for pyrolytic carbon implants were similar to those of Co-Cr alloy implants at 24 weeks. At 24 weeks, the mean total score for Co-Cr alloy implants was 11.6 ± 0.7, while at 52 weeks, the mean total score for the pyrolytic carbon implants was 11.7 ± 1.3.

Fig. 5
figure 5

MFC histologic scores, means. a Cartilage flow over implant. b Implant-bone apposition. c Implant-cartilage interface. d Cartilage morphology. *p < 0.05

Fig. 6
figure 6

52-week histologic sections: microradiographs of pyrolytic carbon (top) and Co-Cr alloy (bottom) implants. Note radiolucent pyrolytic carbon coating surrounding radio-dense substrate (×2)

Fig. 7
figure 7

52-week sections of a pyrolytic carbon (left) and Co-Cr alloy (right) implant. Toluidine blue, basic fuchsin, magnification: ×2

Fig. 8
figure 8

Mean total histologic scores for MFC cartilage. Significance, p < 0.05*

There were no significant differences (paired t test, p > 0.05) observed between the two test groups regarding the quantitative measurements of mean percent bone contact (p = 0.617), percent soft tissue contact (p = 0.470), and percent void space at the implant interface (p = 0.964) (Table 3).

Table 3 Quantitative measurements of histologic parameters at the bone-implant interface

Tibial articular cartilage evaluation

Overall, the pyrolytic carbon implant group had superior histologic appearances for the medial tibia articulating surface over that of the Co-Cr alloy implant group at all evaluation periods (Fig. 9). In most pyrolytic carbon sections, the cartilage surface appeared normal with minimal mechanical damage or cellular changes. Isolated areas of cell clusters with early mechanical changes were observed in limited sections (Fig. 9, top right). Loss of matrix staining was observed for most Co-Cr alloy sections with cellular changes present, as well as mechanical damage at the cartilage surface (Fig. 9, bottom right). There was no significant difference in scores at 12 weeks; however, mean total histologic scores of the tibial articular cartilage were significantly improved at 24 weeks (p = 0.001) and 52 weeks (p < 0.001) for the pyrolytic carbon implant group (Fig. 10). Regarding within-animal paired comparison at 52 weeks, pyrolytic carbon was superior to Co-Cr alloy in all subcategories (p < 0.05). In eight of nine paired comparisons, the overall histologic score of the tibial surface was superior for the pyrolytic carbon implant side than the Co-Cr alloy side, with no statistically significant difference in the remaining comparison pair.

Fig. 9
figure 9

Tibia cartilage surfaces articulating against pyrolytic carbon (top) and Co-Cr (bottom), 52 weeks. ×2 (left), ×10 (right)

Fig. 10
figure 10

Mean total histologic scores for the medial menisco-tibial surface. *Significance, p < 0.05

At 12 weeks, changes were primarily observed in the cellular morphology of the tibial cartilage, while structural changes were noted at both 12 and 52 weeks. Occasional loss of columnar orientation with cell clusters and loss of cell viability were observed at 12 weeks, as well as some loss of matrix GAG staining. At 24 weeks, cartilage surface changes were first observed with moderate irregularities, particularly for the Co-Cr alloy implants. Degenerative changes occurred to a lesser extent in the pyrolytic carbon group. Histologic scores decreased significantly from 12 to 24 weeks for both implant materials, with a greater decrease for the Co-Cr alloy group from 20.3 ± 2.3 to 16.2 ± 2.8 (p < 0.0001) than for the pyrolytic carbon group which decreased from 21.3 ± 1.9 to 19.0 ± 2.4 (p = 0.0005). Mean total histologic scores stabilized at 52 weeks compared to the earlier evaluation periods. The mean total histologic score of the pyrolytic carbon implants was significantly improved compared to that of the Co-Cr alloy specimens (p < 0.001) with mean total histologic scores of 21.9 ± 1.0 and 16.7 ± 4.3, respectively. Histologic appearances of the tibial cartilage and meniscus at 52 weeks were similar to those at 24 weeks for each respective implant material.

Discussion

This study demonstrated that a pyrolytic carbon hemiarthroplasty implant material was superior to identical Co-Cr alloy implants. Less cartilage degeneration was observed in the cartilage adjacent to and in the vicinity of the pyrolytic carbon implants compared to the Co-Cr alloy implants in the medial femoral condyle at all evaluation periods. Surface cartilage wear, degradation, and cellular change were reduced when articulating against the pyrolytic carbon implants. In particular, changes in the tibial cartilage observed for the pyrolytic carbon group at 52 weeks were seen as early as 12 weeks for the Co-Cr alloy group. Both implant groups achieved a similar degree of direct bone-implant apposition at 12, 24, and 52 weeks.

The concept of a minimally invasive hemiarthroplasty for the treatment of focal osteochondral knee defects offers the advantages of reduced pain, a shorter hospital stay, and increased range of motion. Hemiarthroplasty also preserves bone stock, allowing for future revision or total joint replacement, if needed. While most devices require replacement of the opposing tibial articular surface, the device in this study does not and is comparable in concept to the current marketed device that requires resurfacing of only one articular surface—the HemiCAP (Arthrosurface Inc., Franklin, MA).

The HemiCAP consists of a bone fixation element and an articular component connected by a Morse taper. The bearing surface is Co-Cr-Mo alloy with titanium plasma spray on the underside for bone ongrowth. The biological and functional response of the HemiCAP was investigated in goats [16]. Radiologically, there was no evidence of implant failure or loosening nor any gross degenerative changes. Histological analysis showed new trabecular bone abutting the implant in all specimens at 1 year postoperatively. The medial femoral condyle cartilage lateral to the implant was fibrocartilage-like, whereas it was hyaline cartilage-like medial to the implant [16]. Histologic examination of the proximal tibia cartilage surface opposing the HemiCAP implant was characterized by the presence of fibrillations, similar to those observed in this study for the Co-Cr alloy group. Given its high fatigue and high wear resistance, biocompatibility, reduced elastic modulus, and propensity for SAPL adhesion to form a boundary lubricant, pyrolytic carbon offers the potential for improved clinical performance of implants for this partial joint resurfacing application compared to Co-Cr alloy.

One of the limitations of the surgical model used is that the implants were placed in a joint that was not truly arthritic. The implants were placed in a joint at the same time that the defect was made. This study also did not include control groups with osteochondral defects that were left untreated or, as previously stated, defects that were left untreated for a substantial period of time prior to implantation. It is important to note that it has been shown that untreated osteochondral defects result in deterioration of both the adjacent cartilage and the opposing cartilage on which it articulates [15].

In a study comparing the results of untreated critical-size cartilage defects in the medial femoral condyle of goats with defects treated with oxidized zirconium or Co-Cr small hemiarthroplasty implants after 52 weeks, 13 of 16 analyzed implants showed good osseointegration and high bone-implant contact (40–60%) [39]. Previous rabbit studies showed similar bone-implant contact percentages, ranging from 36 ± 4% [40] to 47.5 ± 4.7% [41]. The present study had comparable bone-implant contact with a mean of 34.5  ± 15.9% for the Co-Cr alloy implants and 30.2  ± 20.4% for the pyrolytic carbon implants.

Although fibrillation was rarely seen by Custers et al. [39], a previous study involving fixation of pyrolytic carbon and titanium implants in mongrel dogs showed moderate fibrillation of the opposing cartilage surface by the pyrolytic carbon implant and severe fibrillation by the titanium device at 12 months [42]. In the present study, no changes on the medial tibia plateau surface opposing the pyrolytic carbon implant were observed, but moderate fibrillation of the opposing tibia cartilage surface was observed for one of the three knees treated with Co-Cr alloy implants at 52 weeks. In another study by Cook et al. [28] using hip endoprosthesis in a canine model, areas of wear were much less extensive in animals with pyrolytic carbon devices, and there was significantly less fibrillation of opposing cartilage seen with the pyrolytic carbon implants compared to both Ti-6Al-4V and Co-Cr-Mo alloy devices (all p < 0.0075). Based on the direct comparison of pyrolytic carbon to identical metal alloy implants, it is hypothesized that the improved performance of pyrolytic carbon devices results from reduced material elastic modulus, as well as lower surface energy and the non-adhesive nature of the pyrolytic carbon surface [43]. In addition, the high affinity of SAPL to the surface of pyrolytic carbon assists in the formation of a boundary lubricant for reduced wear and friction during articulation [34, 35] which could contribute to the improved outcomes on the opposing cartilage surface.

Another limitation to this study is the small number of animals, which may skew statistical elements. However, bilateral surgery allows for intra-animal pair-wise comparison and therefore a reduced number of animals needed for the study. It also allows a direct comparison of the two implant materials. Studies performed in a larger sheep model comparing pyrolytic carbon implants to a chondroplasty control group are underway.

Conclusions

In summary, the use of pyrolytic carbon as a hemiarthroplasty implant material was shown to be superior to Co-Cr alloy, which is the material that is currently being used in a marketed clinically available hemiarthroplasty knee device. Less degeneration was observed in the cartilage adjacent to and in the vicinity of the pyrolytic carbon implants compared to the Co-Cr alloy implants in the medial femoral condyle at all evaluation periods out to 1 year. There was also less wear, degradation, and cellular changes of the tibial cartilage surface when articulating against the pyrolytic carbon implants. Changes in the tibial cartilage observed for the pyrolytic carbon group at 52 weeks were seen as early as 12 weeks for the Co-Cr alloy group. Again, larger sheep models comparing a clinical pyrolytic carbon device to control chondroplasty-treated defects are underway.

Abbreviations

ANOVA:

Analysis of variance

AP:

Anterior-posterior

Co-Cr:

Cobalt-chromium

Co-Cr-Mo:

Cobalt-chromium-molybdenum

DPPC:

Dipalmitoylphosphatidylcholine

MFC:

Medial femoral condyle

SAPL:

Surface-active phospholipids

TKA:

Total knee arthroplasty

References

  1. Schindler OS. (iv) Articular cartilage surgery in the knee. Orthopaedics and Trauma. 2010;24(2):107–20.

    Article  Google Scholar 

  2. Scopp JM, Mandelbaum BR. Osteochondral injury of the knee. Orthopaedic Sports Medicine. 2005;2(3):1–12.

    Google Scholar 

  3. Baumgaertner MR, Cannon WD, Vittori JM, Schmidt ES, Maurer RC. Arthroscopic debridement of the arthritic knee. Clin Orthop Relat Res. 1990;253:197–202.

    Google Scholar 

  4. Dervin GF, Stiell IG, Rody K, Grabowski J. Effect of arthroscopic debridement for osteoarthritis of the knee on health-related quality of life. J Bone Joint Surg Am. 2003;85A(1):10–9.

    Article  Google Scholar 

  5. Siparsky P, Ryzewicz M, Peterson B, Bartz R. Arthroscopic treatment of osteoarthritis of the knee. Clin Orthop Relat Res. 2007;455:107–12. doi:10.1097/BLO.0b013e31802fc18c.

    Article  PubMed  Google Scholar 

  6. Sprague NF. Arthroscopic debridement for degenerative knee joint disease. Clin Orthop Relat Res. 1981;160:118–23.

    Google Scholar 

  7. Mithoefer K, Williams RJ, Warren RF, Potter HG, Spock CR, Jones EC, Wickiewicz TL, Marx RG. The microfracture technique for the treatment of articular cartilage lesions in the knee. A prospective cohort study. J Bone Joint Surg Am. 2005;87(9):1911–20. doi:10.2106/JBJS.D.02846.

    PubMed  Google Scholar 

  8. Steadman JR, Briggs KK, Rodrigo JJ, Kocher MS, Gill TJ, Rodkey WG. Outcomes of microfracture for traumatic chondral defects of the knee: average 11-year follow-up. J Arthroscopic Rel Surg. 2003;19(5):477–84. doi:10.1053/jars.2003.50112.

    Article  Google Scholar 

  9. Gudas R, Kalesinskas RJ, Kimtys V, Stankevicius E, Toliusis V, Bernotavicius G, Smailys A. A prospective randomized clinical study of mosaic osteochondral autologous transplantation versus microfracture for the treatment of osteochondral defects in the knee joint in young athletes. J Arthro Rel Surg. 2005;21(9):1066–75. doi:10.1016/j.arthro.2005.06.018.

    Article  Google Scholar 

  10. Hangody L, Feczko P, Bartha L, Bodo G, Kish G. Mosaicplasty for the treatment of articular defects of the knee and ankle. Clin Orthop Relat Res. 2001;391S:S328–36.

    Article  Google Scholar 

  11. Aggarwal VK, Goyal N, Deirmengian G, Rangavajulla A, Parvizi J, Austin MS. Revision total knee arthroplasty in the young patient: is there trouble on the horizon? J Bone Joint Surg Am. 2014;96:536–42. doi:10.2106/JBJS.M.00131.

    Article  PubMed  Google Scholar 

  12. Diduch DR, Insall JN, Scott WN, Scuderi GR, Font-Rodriguez D. Total knee replacement in young, active patients: long-term follow-up and functional outcome. J Bone Joint Surg Am. 1997;79:572–82.

    Article  Google Scholar 

  13. Keeny JA, Eunice S, Pashos G, Wright RW, Clohisy JC. What is the evidence for total knee arthroplasty in young patients? A systematic review of the literature. Clin Orthop Relat Res. 2011;469(2):574–83. doi:10.1007/s11999-010-1536-9.

    Article  Google Scholar 

  14. Parvizi J, Nunley RM, Berend KR, Lombardi AV, Ruh EL, Clohisy JC, Hamilton WG, Valle CJD, Barrack RL. High level residual symptoms in young patients after total knee arthroplasty. Clin Orthop Relat Res. 2014;472(1):133–7. doi:10.1007/s11999-013-3229-7.

    Article  PubMed  Google Scholar 

  15. Kawalec JS, Hetherington VJ, Melillo TC, Corbin N. Evaluation of fibrocartilage regeneration and bone response at full-thickness cartilage defects in articulation with pyrolytic carbon or cobalt-chromium alloy hemiarthroplasties. J Biomed Mater Res. 1998;41:534–40.

    Article  CAS  PubMed  Google Scholar 

  16. Kirker-Head CA, Van Sickle DC, Ek SW, McCool JC. Safety of, and biological and functional response to, a novel metallic implant for the management of focal full-thickness cartilage defects: preliminary assessment in an animal model out to 1 year. J Orthop Res. 2006;24(5):1095–108. doi:10.1002/jor.20120.

    Article  PubMed  Google Scholar 

  17. Ushio K, Oka M, Hyon SH, Yura S, Toguchida J, Nakamura T. Partial hemiarthroplasty for the treatment of osteonecrosis of the femoral head. An experimental study in the dog. J Bone Joint Surg (Br). 2003;85(6):922–30.

    CAS  Google Scholar 

  18. Waldorff EI, Roessler BJ, Zachos TA, Miller BS, McHugh J, Goldstein SA. Preclinical evaluation of a novel implant for treatment of a full-thickness distal femoral focal cartilage defect. J Arthroplasty. 2013;28(8):1421–9. doi:10.1016/j.arth.2012.11.020.

    Article  PubMed  Google Scholar 

  19. Amstutz HC, Grigoris P, Safran MR, Grecula MJ, Campbell PA, Schmalzried TP. Precision-fit surface hemiarthroplasty for femoral head osteonecrosis: long-term results. J Bone Joint Surg (Br). 1994;76(3):423–7.

    CAS  Google Scholar 

  20. McCann L, Ingham E, Jin Z, Fisher J. An investigation of the effect of conformity of knee hemiarthroplasty designs on contact stress, friction and degeneration of articular cartilage: a tribological study. J Biomechanics. 2009;42:1326–31. doi:10.1016/j.jbiomech.2009.03.028. Epub 2009 Apr 19.

    Article  CAS  Google Scholar 

  21. Murray DW, Rushton N. Macrophages stimulate bone resorption when they phagocytose particles. J Bone Joint Surg (Br). 1990;72(6):988–92.

    CAS  Google Scholar 

  22. Reilly DT, Burnstein AH. Review article. The mechanical properties of cortical bone. J Bone Joint Surg Am. 1974;56(5):1001–22.

    Article  CAS  PubMed  Google Scholar 

  23. Hills BA, Butler BD. Phospholipids identified on the pericardium and their ability to impart boundary lubrication. Ann Biomed Eng. 1985;13(6):573–86.

    Article  CAS  PubMed  Google Scholar 

  24. Hills BA. Remarkable anti-wear properties of joint surfactant. Ann Biomed Eng. 1995;23(2):112–5.

    Article  CAS  PubMed  Google Scholar 

  25. Hills BA, Monds MK. Deficiency of lubricating surfactant lining the articular surfaces of replaced hips and knees. Br J Rheumatol. 1998;37(2):143–7.

    Article  CAS  PubMed  Google Scholar 

  26. Purbach B, Hills BA, Wroblewski BM. Surface-active phospholipid in total hip arthroplasty. Clin Orthop Relat Res. 2002;396:115–8.

    Article  Google Scholar 

  27. Cook S, Patron L, Salkeld SL, Klawitter JJ, Beckenbaugh RD. Pyrolytic carbon as an implant material for small joint replacement. In: Wise DL, editor. Biomaterials and Bioengineering Handbook. New York.: Marcel Dekker; 2000. p. 383–96.

    Google Scholar 

  28. Cook SD, Thomas KA, Kester MA. Wear characteristics of the canine acetabulum against different femoral prostheses. J Bone Joint Surg (Br). 1989;71(2):189–97.

    Article  CAS  Google Scholar 

  29. Cook SD, Weinstein AM, Klawitter JJ, Kent JN. Quantitative histologic evaluation of LTI carbon, carbon-coated aluminum oxide and uncoated aluminum oxide dental implants. J Biomed Mater Res. 1983;17(3):519–38. doi:10.1002/jbm.820170311.

    Article  CAS  PubMed  Google Scholar 

  30. Haubold AD. On the durability of pyrolytic carbon in vivo. Med Prog Technol. 1994;20(3-4):201–8.

    CAS  PubMed  Google Scholar 

  31. Anderson RC, Cook SD, Weinstein AM, Haddad Jr RJ. An evaluation of skeletal attachment to LTI pyrolytic carbon, porous titanium, and carbon-coated porous titanium implants. Clin Orthop Relat Res. 1984;182:242–57.

    CAS  Google Scholar 

  32. Cook SD, Beckenbaugh RD, Redondo J, Popich LS, Klawitter JJ, Linscheid RL. Long-term follow-up of pyrolytic carbon metacarpophalangeal implants. J Bone Joint Surg Am. 1999;81(5):635–48.

    Article  CAS  PubMed  Google Scholar 

  33. Thomas KA, Cook SD, Renz EA, Anderson RC, Haddad RJ, Haubold AD, Yapp R. The effect of surface treatments on the interface mechanics of LTI pyrolytic carbon implants. J Biomed Mater Res. 1985;19(2):145–59. doi:10.1002/jbm.820190205.

    Article  CAS  PubMed  Google Scholar 

  34. Gale LR, Coller R, Hargreaves DJ, Hills BA, Crawford R. The role of SAPL as a boundary lubricant in prosthetic joints. Tribol Int. 2007;40:601–6.

    Article  CAS  Google Scholar 

  35. Gale LR. Biotribological assessment for artificial synovial joints: the role of boundary lubrication. 2007. http://eprints.qut.edu.au/29159/3/Lorne_Gale_Thesis.pdf. Accessed 31 May 2016.

  36. Paradis M, Sauve F, Charest J, Refsal KR, Moreau M, Dupuis J. Effects of moderate to severe osteoarthritis on canine thyroid function. Can Vet J. 2003;44(5):407–12.

    PubMed  PubMed Central  Google Scholar 

  37. Mainil-Varlet P, Aigner T, Bullough P, Hollander A, Hunziker E, Kandel R, Nehrer S, Pritzker K, Roberts S, Stauffer E. The International Cartilage Repair Society (ICRS)—Histological Visual Scale. A preliminary report of the histological end point committee. I Human biopsies, Toronto consensus. Euro Cells and Mater. 2002;4(Suppl1):10.

    Google Scholar 

  38. McDonald JH. Handbook of biological statistics. 3rd ed. Baltimore: Sparky House Publishing; 2014. p. 157–64.

    Google Scholar 

  39. Custers RJH, Dhert WJA, Saris DBF, Verbout AJ, van Rijen MHP, Mastbergen SC, Lafeber FPJG, Creemers LB. Cartilage degeneration in the goat knee caused by treating localized cartilage defects with metal implants. Osteoarthritis Cartilage. 2010;18(3):377–88. doi:10.1016/j.joca.2009.10.009. Epub 2009 Oct 23.

    Article  CAS  PubMed  Google Scholar 

  40. Thomsen P, Larsson C, Ericson LE, Sennerby L, Lausmaa J, Kasemo B. Structure of the interface between rabbit cortical bone and implants of gold, zirconium and titanium. J Mater Sci Med. 1997;8(11):653–65.

    Article  CAS  Google Scholar 

  41. Custers RJH, Dhert WJA, van Rijen MHP, Verbout AJ, Creemers LB, Saris DBF. Articular damage caused by metal plugs in a rabbit model for treatment of localized cartilage defects. Osteoarthritis Cartilage. 2007;15(8):937–45. doi:10.1016/j.joca.2007.02.007. Epub 2007 Mar 21.

    Article  CAS  PubMed  Google Scholar 

  42. Cook SD, Anderson RC, Thomas KA, Kester MA, Haddad RJ. Articular response to implant material modulus and method of fixation, presented at the 11th Annual Meeting of the Society of Biomaterials. Mount Laurel: Society for Biomaterials; 1985. p. 90.

  43. Haubold AD, Shim HS, Bokros JC. Carbon in medical devices. In: Williams DF, editor. Biocompatibility of clinical implant materials, vol. 2. Boca Raton: CRC Press; 1981. p. 3–42.

    Google Scholar 

Download references

Acknowledgements

None

Funding

This work was supported by the Joe W. and Dorothy Dorsett Brown Foundation.

Availability of data and materials

The datasets during and/or analyzed during the current study are available from the corresponding author on reasonable request.

Authors’ contributions

All authors participated in the surgery, contributed to the manuscript preparation, and approved the final manuscript.

Competing interests

The authors declare that they have no competing interests.

Consent for publication

Not applicable

Ethics approval

This study received approval from the In-Life Facility’s IACUC committee for all animal care and procedures.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Samantha L. Salkeld.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Salkeld, S.L., Patron, L.P., Lien, J.C. et al. Biological and functional evaluation of a novel pyrolytic carbon implant for the treatment of focal osteochondral defects in the medial femoral condyle: assessment in a canine model. J Orthop Surg Res 11, 155 (2016). https://doi.org/10.1186/s13018-016-0488-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13018-016-0488-5

Keywords