Significantly reducing the presurgical preparation time for anterior pelvic fracture surgery by faster creating patient-specific curved plates

Abstract

Background

To shorten the preoperative preparation time, reconstruction plates were designed using the computed tomography (CT)-based three-dimensional (3D) medical imaging surgical planning software OOOPDS. In addition, 3D printing was used to generate curved plates for anterior pelvic fracture surgeries.

Methods

This study analyzed two groups with the same 21 patients who underwent surgery for traumatic anterior pelvic ring fractures. In Group 1, the direct reconstruction plates were preoperatively contoured according to the anatomical 3D-printed pelvic model. In Group 2, the fixation plates were contoured according to the 3D printed plate templates, which were created based on the simulated plate templates by the OOOPDS software. The processing time, including the 3D printing time for the pelvic models in Group 1, the 3D printing time for the fixation plate templates in Group 2, and the pre-contouring time for the plates in both groups, was recorded.

Results

The mean time of pre-contouring for the curved reconstruction plates in Group 2 was significantly less than in Group 1 (−55 min; P < 0.01). The mean time of 3D printing for the 3D plate template model in Group 2 was significantly less than that for the 3D pelvic model in Group 1 (−869 min; P < 0.01). Experimental results showed that the printing time for the plate pre-contouring and the 3D plate templates could be effectively reduced by approximately 93% and 90%, respectively.

Conclusion

This method can shorten the preoperative preparation time significantly.

Introduction

Pelvic ring injuries constitute only 2 to 8% of all fractures but occur in 20% of polytrauma patients, with a mortality rate of 10 to 16% [1]. Unstable pelvic fractures are often caused by a high-energy force, such as road traffic accidents, falls from a height, and localized crush injuries [2], and may result in uncontrolled hemorrhage leading to a high morbidity rate. It is a consensus that surgical intervention is required to treat unstable pelvic fractures. Pelvic fixation has traditionally been divided into posterior and anterior fixation. Although pelvic stability is mainly sustained by the posterior ring, the anterior ring provides 30% of the pelvic stability [3]. The fracture pattern dictates the type of implants and fixation strategy. Surgical intervention may be isolated to the posterior or combine posterior and anterior surgical fixations [4, 5]. Although stable and accurate posterior ring fixation remains important, the recognition that each injured pelvic ring element is a potential site of instability and deformity has driven the improved evaluation and fixation of the anterior pelvis.

Techniques for stabilizing the anterior pelvic ring include external fixation, symphyseal plating, intramedullary ramus screws, and an anterior subcutaneous internal fixator. Open reduction and internal fixations (ORIF) are associated with prolonged operative times and morbidities, while external fixators are associated with high complication rates. Plate fixation can be used for ramus fixation or to span both an injured ramus and symphysis pubis. In most instances, plate and screw fixation requires a formal open surgical approach to access the injured element(s) of the anterior ring.

The introduction of three-dimensional (3D) printing [6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22] to surgical planning has gained importance, considering the improvements in the accuracy and precision of surgical implant preparation, especially in pelvic surgeries. Pelvic fracture surgeries conventionally need complete access to the surgical site and intraoperative implant contouring following the fracture reduction [15, 16, 23,24,25]. Nevertheless, such an invasive approach invariably leads to prolonged surgeries and excess bleeding due to the complex regional anatomy and complicated fracture configurations [26]. Therefore, to present pelvic fracture patterns to surgeons for proper evaluation, 3D printing technology and virtual surgical simulation systems based on computed tomography (CT) have become essential methods for preoperative planning [15, 16, 27,28,29,30,31]. However, according to the study by Yeh et al. [16], printing life-size 3D pelvic models to shape customized implants is time-consuming.

In this study, a dedicated semi-automatic patient-specific reconstruction plate design system was used for anterior pelvic ring fracture surgeries combined with a newly introduced method using the OOOPDS software Version 1.06 (Taiwan Main Orthopaedic Biotechnology Co., Ltd; Taichung City, Taiwan) to create a curved plate from a series of selected visual points from the imaging. This study will provide a user-friendly interface for fracture reduction simulations and semi-automatic personalized plate design for fast preoperative implant templating. This study hypothesized that implant pre-contouring according to the 3D printed plate template model created based on the semi-automatic reconstruction system would be more efficient than plate pre-contouring according to the actual 3D printed pelvic model.

Materials and methods

Patient collection and image data acquisition

This retrospective study analyzed data from 21 patients with traumatic anterior pelvic ring fractures who underwent surgery at the Tri-Service General Hospital in Taiwan from November 2016 to February 2020. Pelvic CT images (3-mm axial slices) were obtained and saved in Digital Imaging and Communication in Medicine (DICOM) format. The image resolution ranged from 0.6 to 1.0 mm. Informed consent was obtained from all the patients, and the Institutional Review Board of the Tri-Service General Hospital approved this study.

Segmentation and anatomical 3D virtual model reconstruction

Each patient’s pelvic thin-slice CT image was imported into the 3D medical image processing software (OOOPDS Version 1.06, Taiwan). The OOOPDS software’s volume-rendering technique was used to visualize the fracture, remove the surrounding tissues, and separate the structural parts from the soft tissue according to the variant threshold. After the bony structure was separated from the soft tissue, using the splitting process, the bilateral femurs were erased, and the pelvis was isolated. Different colors were assigned to the different fracture fragments, and each fracture fragment was divided into separate parts following the segmentation process. The software reduction techniques for fractured bones included segmentation, split, mirror, and manual repositioning techniques depending on the fracture patterns. After the 3D software processing, the simulated 3D pelvic model could be visualized from all directions during the virtual repositioning. Finally, the patient-specific anatomical reduction 3D pelvic model was reconstructed and saved in the stereolithography (STL) format.

Selection of bone surface points for customized reconstructed fixation plate

After the virtual reduction was completed, the curvature could be designed for ease of clinical use upon evaluating the position of the plate unit from a series of selected visual points (Fig. 1). Different fixation plates (Civic, Taiwan; DePuy Synthes, Switzerland; Zimmer, USA) could be chosen from the information library. An In-house Design unit was also created in the system for future studies. The orthopedic surgeon decided on the surface points on the pelvic models according to previous photographic records, and then the patient-specific plate template was generated automatically (Fig. 2).

Fig. 1
figure 1

The semi-automatic patient-specific reconstruction plate design system

Fig. 2
figure 2

The 3D CAD models of each of the fixation plate units in the information library (Civic, DePuy Synthes, Zimmer, and In-house Design)

3D printing technique

These patient-specific pelvic models (1:1 scale ratio) and plate templates were exported in the STL format and fabricated by a Fused Deposition Modeling (FDM) printer (Fortus 360, Stratasys, USA) with acrylonitrile butadiene styrene (ABS). The following print settings were used for all the 3D printing: travel speed 160 mm/s, print speed 65 mm/s, infill density 50%, layer height 0.2 mm, and support structures printed as lines with a thickness of 5% for structures with an overhang over 70°. The time of alignment, slicing, and printing was measured.

Fixation plate pre-bending process

This study used two groups to compare the plate pre-contouring time. Group 1 was composed of 21 patients with traumatic anterior pelvic ring fractures who had undergone surgery, and the straight reconstruction plate was contoured preoperatively according to the anatomical 3D pelvic model. The pre-contouring time of the plate before the surgery was recorded. In Group 2, using the same patients, the fixation plate template was generated using the semi-automatic plate generation system and 3D printing technique. The time spent shaping the straight reconstruction plate based on the 3D printed fixation plate template was recorded. The 3D-printing time for the pelvic models in Group 1 and the 3D-printing time for the plate template in Group 2 was also compared. All procedures were performed by the same orthopedic surgeon and surgical team. The flowchart of this study is shown in Fig. 3.

Fig. 3
figure 3

A flowchart of this study

Data analysis

Quantitative data are expressed as the mean ± standard deviation. Statistical analyses were performed using the Statistical Package for the Social Sciences software (version 22, SPSS, Inc., Chicago, IL, USA). A Wilcoxon signed-rank test was used in this study. A P-value of less than 0.05 was considered statistically significant.

Results

A total of 21 cases were included in this study. In Group 1, the mean printing time for the life-size anatomical pelvic 3D model was 926.9 ± 202.95 minutes. The mean time for the semi-automatic generation of the 3D plate template in Group 2 was 58.29 ± 33.45 minutes. The difference between the two groups was statistically significant (P < 0.01), and the average 3D-printing time was reduced by 90%. Individual data are shown in Fig. 4.

Fig. 4
figure 4

The calculated 3D printing time comparison between Group 1 (3D pelvic model) and Group 2 (3D plate template)

The time required for preoperatively contouring the plate using the anatomical 3D pelvic model in Group 1 was 62.50 ± 21.45 minutes. In Group 2, contouring the plate using the semi-automatically generated plate template took 6.24 ± 2.39 minutes. There was a significant difference between the groups (P < 0.01), and the average pre-contouring time was reduced by 93%. Individual data are presented in Fig. 5.

Fig. 5
figure 5

The comparison of the calculated plate pre-contouring time between Group 1 (3D pelvic model) and Group 2 (3D plate template)

Discussion

This study showed that the time required for the 3D printing of the plate template model in Group 2 was significantly less than in Group 1 (P < 0.01). This finding may have resulted from the size of the 3D model. In Group 1, the life-size anatomical pelvic model was printed, whereas, in Group 2, only the plate template was printed. Hence, the printing time for the 3D plate template was reduced by approximately 90% by using the new method. Moreover, the mean pre-bending time in Group 2 was significantly less than in Group 1 (P < 0.01). This result implies that the surgical team contoured the fixation plate more efficiently, according to the 3D printed plate template than according to the 3D printed pelvic model. Thus, the pre-bending time was reduced by approximately 93% using the new semi-automatic plate design system. Compared to the whole pelvic model, the plate bending time was reduced significantly by using an isolated plate template model since the template provided precise information on the orientation and curvature of the plate. Additionally, the interference by the bony pelvic structure was avoided. Compared with Group 1, the reduction in time seen in Group 2 was due to forming the semi-automated plate template using the software. In this study, using this software, the average time for performing the semi-automated plate template was about ten minutes. In addition to the reduced time in Group 2, the cost was also reduced due to the different size of the model. Using this semi-automatic patient-specific reconstruction plate design system, the average ABS material cost for one 3D printing plate template (in Group 2) was about $1.50 US dollars. The average ABS material cost for one 3D printing whole pelvic model was about $220.00 US dollars due to the larger size of the model.

The software utilized a normal vector generated from the surface to ensure that each unit’s profile aligned parallel to the bone surface. Furthermore, algorithms were incorporated into the software to construct an optimal path. A threshold value was established in the generation formula to prevent the formation of a plate that would penetrate the surface. The smoothing function in the software was used to create smooth parts. A good fracture reduction was important for the virtual simulation in the software. When dealing with areas of poor continuity due to inadequate fracture reduction, the wrap function was employed. To ensure proper line length matching with a set of plate units, the line was cropped when the line was shorter than the mid-line of the fixation plate unit, and the line was lengthened when the line was longer than the mid-line of the fixation plate unit.

Pelvic ring fracture surgery is a challenging task for orthopedic surgeons. The surgery’s difficulties lie in the complex anatomy of the pelvis, the diversity of fracture morphology, and the inconvenience of contouring plates; thus, detailed preoperative planning combined with accurately contouring plates can ensure the success of pelvic ring fracture surgeries [30]. Moreover, it is essential to develop a preoperative surgical procedure that avoids suboptimal reductions [31]. Using virtual surgical planning tools with medical image data can facilitate accurate surgical planning and create a contoured plate appropriate for the patient’s anatomy [17]. Surgeons can determine the best sequential reduction procedure and choose the proper surgical approach by manipulating the segmented bones in a virtual simulation. In addition, fracture reduction can be more efficient during pelvic surgery when the pre-contoured plate serves as an anatomic plate; the concept is similar to using the anatomical locking plate for fracture fixation for the indirect reduction technique.

Making anatomical models using the patient’s medical imaging data with 3D printers is feasible [32]. The 3D printing method allows for the rapid construction of full-scale anatomical models to facilitate the visualization of intricate pelvic fracture patterns before surgery. More recently, studies have presented 3D printing technology and virtual planning techniques for pelvic ring fractures. These techniques can improve a surgeon’s efficiency, reduce iatrogenic complications, and shorten surgical time [17, 33]. To plan acetabular fracture surgery, Duncan et al. used a life-size model made by 3D printing technology and medical software, which converted DICOM data into an STL format [34]. Similarly, Brown et al. reported desirable results when using computer-generated 3D-moving representations to plan the placement of the plates to fix pelvic fractures [28, 35]. Maini et al. concluded that a patient-specific pre-contoured plate made using the 3D model was a better implant than an intraoperatively contoured plate [36]. Collectively, this growing body of literature demonstrates that 3D printing-assisted surgery has significant advantages in reducing the amount of intraoperative blood loss and shortening the duration of the surgery.

Chen et al. [33] indicated that all the preoperative preparations could take 36 hours. Therefore, 3D-model printing is the key to preoperative preparation time. Previously, solid pelvic models were printed to visualize the 3D structures to decide on the shape of customized implants and screw trajectories. With the novel technique provided by the OOOPDS software, the semi-automatic bone surface points used to generate the patient-specific plate templates significantly reduced the printing and pre-contouring times by 90 and 93%, respectively, in this study.

In bilateral pubic ramus fractures and unilateral pubic ramus fractures that occur near the pubic symphysis, the fixation plate should be placed bilaterally, and the length of the plate should be placed across the pubic symphysis to the contralateral side of the pubic bone. For these cases, a real-size pelvic 3D model should be printed. However, in unilateral pubic ramus fractures near the obturator foramen, the fixation plate should not be placed across the pubic symphysis. In this case, only one-half of a real-size pelvic 3D model should be sufficient for the pre-contouring of the plate, and the estimated printing time for the pelvic model could be reduced half of the time.

This study further pointed out that accurate bends and twists pose noticeable challenges in matching the plate to the template, although twists and gradual curves can mimic the use of manual plate benders. During the pre-contouring of the plate, the bending and curving of the straight plate should be performed between the adjacent screw holes; otherwise, the screw holes could be destroyed and make the part unsuitable for the surgery. Previous studies on the virtual creation of pelvic plate templates have focused solely on the curvature of the templates and have limited consideration of the real fixation plate configuration [23, 37]. In this study, different plates designed by various companies were created, and the selected surface points were produced to connect the plate units. This procedure was a simple method to overcome the problem of matching the plate to the template during pre-contouring.

This study defined a specific goal to successfully evaluate a technology that supports pelvic fracture treatments with the help of a semi-automatic patient-specific reconstruction plate design system and 3D printing. In addition, this study demonstrated the feasibility of a workflow incorporating a semi-automatic plate design system with the implant core unit library and 3D printed plate template technique for plate pre-contouring.

Limitations

This study has some limitations. Since this study was retrospective, the pre-contoured plates in Group 1 had already been placed inside the patient. It was impossible to remove the implants and to do accurate tests with the pre-contoured plates in Group 1. In Group 2, the accuracy tests were performed by placing the pre-contoured plate on the patient’s 3D pelvic model for verification, shown in Fig. 3. All the pre-contoured plates fit the pelvic bone models, and the screw holes could be drilled into the model. In future studies, a prospective study could compare the pre-contoured plates prepared by these two methods by scanning the plates and plate templates to evaluate the fine differences by the software. Second, this study has a comparatively small sample size and did not follow a randomized-controlled and blinded study design. Therefore, a larger patient population is needed to assess its surgical applications further. Third, this study focused on the techniques and initial experiences rather than long-term clinical outcomes. Further studies should prospectively evaluate the effect of the 3D printing-assisted pre-contoured plate fixation methods on treatment outcomes.

Conclusion

This study applied a hybrid scheme combining the curved reconstruction plate simulation and 3D printing technique for the fast construction of patient-specific implants for anterior pelvic fracture surgery. This method can significantly reduce the preoperative preparation time.

Availability of data and materials

The data which support the findings of this study are from the Tri-Service General Hospital. The data are not publicly available since they contain information that could compromise the privacy of the research participants.

Abbreviations

3D:

Three-dimensional

ABS:

Acrylonitrile butadiene styrene

CAD:

Computer-aided design

CT:

Computed tomography

DICOM:

Digital imaging and communication in medicine

STL:

Stereolithography

References

  1. Giannoudis PV, Pape HC. Damage control orthopaedics in unstable pelvic ring injuries. Injury. 2004;35:671–7.

    Article  CAS  PubMed  Google Scholar 

  2. Schmal H, Markmiller M, Mehlhorn AT, Sudkamp NP. Epidemiology and outcome of complex pelvic injury. Acta Orthop Belg. 2005;71:41–7.

    PubMed  Google Scholar 

  3. Bi C, Wang Q, Nagelli C, Wu J, Wang Q, Wang J. Treatment of unstable posterior pelvic ring fracture with pedicle screw-rod fixator versus locking compression plate: a comparative study. Med Sci Monit. 2016;22:3764–70.

    Article  PubMed  PubMed Central  Google Scholar 

  4. Lindahl J, Hirvensalo E, Böstman O, Santavirta S. Failure of reduction with an external fixator in the management of injuries of the pelvic ring: long-term evaluation of 110 patients. J Bone Joint Surg Br. 1999;81:955–62.

    Article  CAS  PubMed  Google Scholar 

  5. Xu R, Ebraheim NA, Robke J, Yeasting RA. Radiologic evaluation of iliosacral screw placement. Spine (Phila PA 1976). 1996;21:582–588.

  6. Gross BC, Erkal JL, Lockwood SY, Chen C, Spence DM. Evaluation of 3D printing and its potential impact on biotechnology and the chemical sciences. Anal Chem. 2014;86:3240–53. https://doi.org/10.1021/ac403397r.

    Article  CAS  PubMed  Google Scholar 

  7. Umair M, Kim WS. An online 3D printing portal for general and medical fields. In International Conference on Computational Intelligence and Communication Networks (CICN). 2015;278–82. https://doi.org/10.1109/CICN.2015.62

  8. Eltorai AEM, Nguyen E, Daniels AH. Three-dimensional printing in orthopedic surgery. Orthopaedics. 2015;38:684–7. https://doi.org/10.3928/01477447-20151016-05.

    Article  Google Scholar 

  9. Zeng C, Xing W, Wu Z, Huang H, Huang W. A combination of three-dimensional printing and computer-assisted virtual surgical procedure for preoperative planning of acetabular fracture reduction. Injury. 2016;47:2223–7. https://doi.org/10.1016/j.injury.2016.03.015.

    Article  PubMed  Google Scholar 

  10. Chen HJ, Gabriel M. A roadmap from idea to implementation: 3D printing for pre-surgical application. CreateSpace Independent Publishing Platform; 2016.

  11. Auricchio F, Marconi S. 3D printing: clinical applications in orthopaedics and traumatology. EFORT Open Rev. 2016;1:121–7. https://doi.org/10.1302/2058-5241.1.000012.

    Article  PubMed  PubMed Central  Google Scholar 

  12. Lal H, Patralekh MK. 3D printing and its applications in orthopaedic trauma: a technological marvel. J Clin Orthop Trauma. 2018;9:260–8. https://doi.org/10.1016/j.jcot.2018.07.022

  13. Cai L, Zhang Y, Chen C, Lou Y, Guo X, Wang J. 3D printing-based minimally invasive cannulated screw treatment of unstable pelvic fracture. J Orthop Surg Res. 2018;13:1–7. https://doi.org/10.1186/s13018-018-0778-1.

    Article  CAS  Google Scholar 

  14. Vaishya R, Patralekh MK, Vaish A, Agarwal AK, Vijay V. Publication trends and knowledge mapping in 3D printing in orthopaedics. J Clin Orthop Trauma. 2018;9:194–201. https://doi.org/10.1016/j.jcot.2018.07.006.

    Article  PubMed  PubMed Central  Google Scholar 

  15. Hung C-C, Li Y-T, Chou Y-C, Chen J-E, Wu C-C, Shen H-C, Yeh T-T. Conventional plate fixation method versus pre-operative virtual simulation and three-dimensional printing-assisted contoured plate fixation method in the treatment of anterior pelvic ring fracture. Int Orthop. 2019;43:425–31. https://doi.org/10.1007/s00264-018-3963-2.

    Article  PubMed  Google Scholar 

  16. Hsu C-L, Chou Y-C, Li Y-T, Chen J-E, Hung C-C, Wu C-C, Shen H-C, Yeh T-T. Pre-operative virtual simulation and three-dimensional printing techniques for the surgical management of acetabular fractures. Int Orthop. 2019;43:1969–76. https://doi.org/10.1007/s00264-018-4111-8.

    Article  PubMed  Google Scholar 

  17. Tsoulfas G, Bangeas PI, Suri JS. 3D printing: applications in medicine and surgery 1st edition. Elsevier; 2019.

  18. Weidert S, Andress S, Suero E, Becker C, Hartel M, Behle M, Willy C. 3D printing in orthopedic and trauma surgery education and training: possibilities and fields of application. Unfallchirurg. 2019;122:444–51. https://doi.org/10.1007/s00113-019-0650-8.

    Article  PubMed  Google Scholar 

  19. Zhang Y-W, Xiao X, Gao W-C, Xiao Y, Zhang S-L, Ni W-T, Deng L. Efficacy evaluation of three-dimensional printing assisted osteotomy guide plate in accurate osteotomy of adolescent cubitus varus deformity. J Orthop Surg Res. 2019;14:1–9. https://doi.org/10.1186/s13018-019-1403-7

  20. Wang J, Cai L, Xie L, Chen H, Guo X, Yu K. 3D printing-based Ganz approach for treatment of femoral head fractures: a prospective analysis. J Orthop Surg Res. 2019;14:1–11. https://doi.org/10.1186/s13018-019-1383-7.

    Article  Google Scholar 

  21. Liu K, Li Z, Ma Y, Lian H. 3D-printed pelvis model is an efficient method of osteotomy simulation for the treatment of developmental dysplasia of the hip. Exp Ther Med. 2020;19:1155–60. https://doi.org/10.3892/etm.2019.8332.

    Article  Google Scholar 

  22. Park JW, Kang HG, Kim JH, Kim H-S. The application of 3D-printing technology in pelvic bone tumor surgery. J Orthop Sci. 2021;262:276–83. https://doi.org/10.1016/j.jos.2020.03.004.

    Article  Google Scholar 

  23. Shen F, Chen B, Guo Q, Qi Y, Shen Y. Augmented reality patient-specific reconstruction plate design for pelvic and acetabular fracture surgery. Int J Comput Assist Radiol Surg. 2013;8:169–79. https://doi.org/10.1007/s11548-012-0775-5.

    Article  PubMed  Google Scholar 

  24. Hou Z, Smith WR, Strohecker KA, Bowen TR, Irgit K, Baro SM, Morgan ST. Hemodynamically unstable pelvic fracture management by advanced trauma life support guidelines results in high mortality. Orthopaedics. 2012;35:e319–24. https://doi.org/10.3928/01477447-20120222-29.

    Article  Google Scholar 

  25. Tile M. Fractures of the acetabulum. In: Schatzker J, Tile M. The rationale of operative fracture care, 3rd ed. Berlin, Heidelberg: Springer, Berlin, 2005. P. 291–340.

  26. Shon HC, Choi S, Yang JY. Three-dimensional printing-assisted surgical technique with limited operative exposure for both-column acetabular fractures. Ulus Travma Acil Cerrahi Derg. 2018;24:369–75. https://doi.org/10.5505/tjtes.2018.47690.

    Article  PubMed  Google Scholar 

  27. Li Y-T, Hung C-C, Chou Y-C, Chen J-E, Wu C-C, Shen H-C, Yeh T-T. Surgical treatment for posterior dislocation of hip combined with acetabular fractures using preoperative virtual simulation and three-dimensional printing model-assisted precontoured plate fixation techniques. Biomed Res Int. 2019;2019:3971571. https://doi.org/10.1155/2019/3971571.

    Article  PubMed  PubMed Central  Google Scholar 

  28. Brown GA, Firoozbakhsh K, Gehlert RJ. Three-dimensional CT modeling versus traditional radiology techniques in treatment of acetabular fractures. Iowa Orthop J. 2001;21:20–4.

    CAS  PubMed  PubMed Central  Google Scholar 

  29. Xiong L, Li X, Li H, Chen Z, Xiao T. The efficacy of 3D printing-assisted surgery for traumatic fracture: a meta-analysis. Postgrad Med J. 2019;95:414–9. https://doi.org/10.1136/postgradmedj-2019-136482.

    Article  PubMed  Google Scholar 

  30. Maini L, Verma T, Sharma A, Sharma A, Mishra A, Jha S. Evaluation of accuracy of virtual surgical planning for patient-specific pre-contoured plate in acetabular fracture fixation. Arch Orthop Trauma Surg. 2018;138:495–504. https://doi.org/10.1007/s00402-018-2868-2.

    Article  PubMed  Google Scholar 

  31. Hessmann MH, Nijs S, Rommens PM. Acetabular fractures in the elderly. Results of a sophisticated treatment concept. Unfallchirurg. 2002;105:893–900. doi:https://doi.org/10.1007/s00113-002-0437-0

  32. Winder J, Bibb R. Medical rapid prototyping technologies: state of the art and current limitations for application in oral and maxillofacial surgery. J Oral Maxillofac Surg. 2005;63:1006–15. https://doi.org/10.1016/j.joms.2005.03.016.

    Article  PubMed  Google Scholar 

  33. Chen K, Yang F, Yao S, Xiong Z, Sun T, Zhu F, Telemacque D, Drepaul D, Ren Z, Guo X. Application of computer-assisted virtual surgical procedures and three-dimensional printing of patient-specific pre-contoured plates in bicolumnar acetabular fracture fixation. Orthop Traumatol Surg Res. 2019;105:877–84. https://doi.org/10.1016/j.otsr.2019.05.011.

    Article  PubMed  Google Scholar 

  34. Duncan JM, Nahas S, Akhtar K, Daurka J. The use of a 3D printer in pre-operative planning for a patient requiring acetabular reconstructive surgery. J Orthop Case Rep. 2015;5:23–5. https://doi.org/10.13107/jocr.2250-0685.247.

    Article  PubMed  PubMed Central  Google Scholar 

  35. Brown GA, Milner B, Firoozbakhsh K. Application of computer-generated stereolithography and interpositioning template in acetabular fractures: a report of eight cases. J Orthop Trauma. 2002;16:347–52. https://doi.org/10.1097/00005131-200205000-00010

  36. Maini L, Sharma A, Jha S, Sharma A, Tiwari A. Three-dimensional printing and patient-specific pre-contoured plate: future of acetabulum fracture fixation? Eur J Trauma Emerg Surg. 2018;44:215–24. https://doi.org/10.1007/s00068-016-0738-6.

    Article  CAS  PubMed  Google Scholar 

  37. Maier D, Kamer L, Noser H, Stankovic Z, Guth A, Bäurle P, Südkamp NP, Köstler W. Morphometric analysis of anatomical implant forms for minimally invasive acetabular fracture osteosynthesis. Comput Aided Surg. 2012;17:240–8. https://doi.org/10.3109/10929088.2012.709278.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

The authors are grateful to the anonymous reviewers for their constructive comments to improve the quality of this paper.

Funding

This work was supported in part by (i) the Tri-Service General Hospital, under Grants TSGH-D-112105, TSGH-B-112015, MND-MAB-112034, TSGH-D-110105, TSGH-B-110008, MND-MAB-110-016, TSGH-NTUST-109-04, TSGH-A-109004, TSGH-B-109007, TSGH-C108-001, MAB-108-034, MND-MAB-C-11109-111035, and TSGH-C107-001, (ii) the National Taiwan University of Science and Technology, under Grant TSGH-NTUST-109-04, and (iii) the Ministry of Science and Technology (MOST), Taiwan, under Grants MOST 109-2221-E-011-074, MOST 110-2221-E-011-121, and MOST 111-2221-E-011-146-MY2.

Author information

Authors and Affiliations

Authors

Contributions

All authors contributed to the study’s conception. T.-T.Y., J.-E.C., and Y.-T.L. participated in the experimental design and data analysis. T.-T.Y. performed the clinical examinations, as well as the data and sample collection. S.S.-D.X., T.-T.Y., and J.-E.C. contributed to the writing of the first draft of the manuscript, and all authors commented on previous versions of the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Tsu-Te Yeh.

Ethics declarations

Ethics approval and consent to participate

All procedures followed were in accordance with the ethical standards and regulations of the responsible committee of the Tri-Service General Hospital. The Tri-Service General Hospital Institutional Review Board approved this study.

Consent for participation

Informed consent was obtained from the individual participants included in this study.

Consent for publication

All authors gave permission for this publication.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Xu, S.SD., Yeh, TT., Chen, JE. et al. Significantly reducing the presurgical preparation time for anterior pelvic fracture surgery by faster creating patient-specific curved plates. J Orthop Surg Res 18, 265 (2023). https://doi.org/10.1186/s13018-023-03749-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13018-023-03749-x

Keywords