Abstract

Background

Operative treatment of humeral shaft fractures (AO/OTA 12) is being performed more frequently. Accordingly, it is important to understand the complications associated with plate fixation. This study analyzes risk factors associated with mechanical failure following plate fixation of humeral shaft fractures in order to further elucidate the mode and location of failure.

Methods

A retrospective review of 351 humeral shaft fractures was completed at a single level I trauma center. Eleven of eighty-five humeral shaft fractures had aseptic mechanical failure requiring revision (12.9%), following initial plate fixation. Fracture characteristics (AO type, comminution, location) and fracture fixation (plate type, multiplanar, number of screws proximal and distal to the fracture) were compared between aseptic mechanical failure and those without failure. A forward stepwise logistic regression analysis was performed to determine any significant predictors of aseptic mechanical failure.

Results

There was significant differences in fixation between the aseptic mechanical failure group and those without failure, specifically in the number of screws for proximal fixation (p = 0.008) and distal fixation (p = 0.040). In the aseptic mechanical failure group, patients tended to have less than < 8 cortices of proximal fixation (82%) and less than < 8 cortices of distal fixation (64%). Conversely, in patients without mechanical failure there was a tendency to have greater than > 8 cortices in both the proximal (62%) and distal fixation (70%). A forward stepwise logistic regression analysis found that less than < 8 cortices of proximal fixation was a significant predictor of aseptic failure, OR 7.96 (p = 0.011). We think this can be accounted for due to the variable bone quality, thinner cortices and multiple torsional forces in the proximal shaft that may warrant special consideration for fixation.

Conclusion

The current dogma of humeral shaft fracture stabilization is to use a minimum of 3 screws proximal and distal to the fracture, however the current study demonstrates this is associated with higher rates of mechanical failure. In contrast, 4 bicortical screws or more of fixation on either side of the fracture had lower failure rates and may help to reduce the risk of mechanical failure.

Level of Evidence Level III.

Introduction

Diaphyseal humerus fractures (AO/OTA 12) have traditionally been managed non-operatively with splinting and functional bracing [1]. However, this treatment paradigm is being challenged, with increasing rates of operative fixation [2]. When operative fixation is employed, it is critical to understand appropriate fixation strategies to achieve bony union and decrease rates of failure.

Operative management can include plate fixation and intermedullary nailing. Plate fixation provides good results including a high rate of union, good functional scores, and low complication rates; in contrast to nail fixation which has been associated with higher shoulder dysfunction and reoperation rates and is indicated mostly for pathologic or highly comminuted fractures [3]. Common complications for open reduction internal fixation (ORIF) of humeral shaft fractures include radial nerve injury, infection, and hardware failure [4]. Recent studies have shown implant failure rates after plate fixation of humerus shaft fractures with a range from 2 to 6% [3,4,5]. When hardware failure occurs, it is important to understand how and where plate fixation fails and factors contributing to this failure. Ideal plate and screw fixation construct for open reduction and internal fixation of humeral shaft fractures remains controversial. Although 6–8 cortices of proximal and distal fixation have been recommended based on expert opinion [1], there is considerable variation in plating techniques and fixation constructs to match the variability in patient and fracture characteristics. Previous biomechanical work on optimal screw configurations, plate type and the use of locking constructs have been studied as a result, but they investigate a very narrow range of fracture patterns and configurations [6, 7]. The information garnered from these studies does not reflect the clinical scenarios routinely faced by surgeons.

This study aims to identify potential risk factors for mechanical failure following humeral shaft ORIF in order to further elucidate the mode and location of failure. We reviewed all patients who underwent humeral shaft ORIF over a 9-year period to evaluate modes and location of failure by fracture type and fixation construct, as well as to determine the risk factors contributing to failure.

Methods

The study was approved by the institutional research ethics board (REB). We performed a retrospective electronic chart review of all patients who underwent operative plate fixation (ORIF) for diaphyseal humeral fractures from 2010 to 2019 at a single, level-one trauma center. Inclusion criteria included all AO/OTA humeral shaft fractures (AO/OTA 12) that were operatively treated with plate fixation (ORIF) in patients > 18 years of age. This included acute fractures and symptomatic non-union or malunion after failed non-operative treatment of humerus shaft fractures. Patients with pathological fractures, previous injury or surgery to the ipsilateral humerus, use of bone graft, nerve or vascular injury aside from radial nerve palsy, or patterns with extension into the proximal or distal segments of the humerus were excluded. Additionally, patients who did not have adequate follow-up to bony union and clinical discharge were also excluded, as failure prior to union could not be captured.

Charts were reviewed by three independent reviewers. Clinical notes and radiographs were reviewed from the time of initial trauma to our predetermined end point for analysis. This was defined as either (a) mechanical failure requiring revision fixation, or (b) successful bony and radiographic union accompanied by clinical discharge by the treating surgeon. The following characteristics were described and quantified for each patient, under the main categories of patient, fracture and fixation characteristics. Patient characteristics included demographic information and presence of associated soft tissue injury (i.e., open fracture status and grade), additional injuries (i.e., polytrauma), and presence of severe polytrauma defined by an Injury Severity Score (ISS) > 15.

Initial injury radiographs were used to obtain fracture characteristics, including classification, presence of comminution, location and extent of the fracture. Fractures were classified by AO/OTA subtype and identify the presence of comminution defined as 3 or more fragments. We defined the humeral diaphysis as the length between the surgical neck of the humerus to the supracondylar ridge. Using this measurement, we were able to define the percent of shaft involved in the fracture by dividing the measured length of the fracture by the length of the shaft. Based on the total length of the shaft, we could define the proximal (0–33%), middle (33–66%) and distal (66–100%) thirds of the diaphysis. Fractures were classified as proximal, middle or distal third fractures if the majority of the length of the fracture was located within that division of the diaphysis. Measurements were averaged between all three reviewers.

Finally, radiographs and operative reports were reviewed to confirm fixation characteristics. These included plate type based on size of screw and plate design (3.5-mm vs. 4.5-mm, broad vs narrow plate). Plate length was determined by the number of available holes for fixation. Fixation strategy was specified including bridging vs rigid fixation (compression plating), use of multiplanar or locking fixation, and cortices engaged above and below the fracture site. A minimum of 8 cortices of fixation was set as a threshold value for adequate fixation as it represents at least 4 bicortical screws, and allowed us to look at a possible difference between 3 and 4 bicortical screws on either side of the fracture. Surgical approaches varied depending on fracture location. Fractures in the proximal 1/3 used the deltopectoral approach, middle 1/3 and distal 1/3 fractures used either a triceps split, paratricipital, or posterolateral approach.

End points were defined as mechanical failure requiring revision fixation or discharge from follow up secondary to radiographic and clinical healing of the fracture. Mechanical failure included screw pull-out, plate bending or breakage and loss of alignment of fracture requiring revision surgery. Failures were independently assessed for cause of failure which was qualitatively described noting presence and location of screw pullout, screw or plate breakage and suboptimal initial alignment or fixation strategies based on basic fracture fixation principles.

Statistical analysis

Qualitative variables were expressed as frequencies and percentages. Fisher’s Exact Test was used to compare categorical data including the rates of polytrauma, presence of open fracture, fracture failure, fracture characteristics such as AO/OTA classification, fixation construction, presence of comminution, and fracture % involvement of humeral shaft by quartile, fracture location, and fixation above and below the fracture. For fracture fixation, both above and below the fracture, we reported whether the fracture fixation included at least 8 screws of fixation. Mean values of age were compared utilizing independent-sample t-tests. A forward stepwise logistic regression analysis was performed to determine which significant variables from the univariate analysis could be modeled as predictors of aseptic failure. Statistical significance was set at p < 0.05. Data were analyzed using Stata/IC 16.1 (StataCorp TX, USA).

Results

A total of 351 patients were initially screened and 85 patients met inclusion criteria, including 45 females and 40 males with a mean age of 47 years (IQR 33). The majority (73%) of patients who underwent operative fixation had multiple injuries. Severely polytraumatized patients (ISS > 15) represented approximately one third (35%) of all eligible patients. These factors were not found to significantly influence rates of aseptic mechanical failure (p > 0.05). We identified 13 patients (15%) who required revision surgery, 2 for infection (2.4%), and 11 for aseptic mechanical failure (13%). The mean time from index procedure to revision surgery was 174 days. There were no differences between groups in rates of aseptic revision by age (p = 0.89) or sex (p = 0.067). A significant increase in the rate of aseptic revision was found for patients with open fractures (p = 0.045) (Table 1).

Table 1 Demographic characteristics of patients requiring revision for aseptic mechanical failure (Group 1), and those who did not (Group 2)

There were significant differences in fixation characteristics between the aseptic mechanical failure group and those without failure, specifically in the number of screws for proximal fixation (p = 0.008) and distal fixation (p = 0.040) (Table 2). In the aseptic mechanical failure group, patients tended to have less than < 8 cortices of proximal fixation (82%) and less than < 8 cortices of distal fixation (64%). Conversely, in patients without mechanical failure there was a tendency to have greater than > 8 cortices in both the proximal (62%) and distal fixation (70%). Otherwise, the remainder of fracture characteristics and implant types were not significant between groups (p > 0.05). This included humerus shaft fracture AO/OTA classification, fracture comminution, fixation type (bridge vs rigid), fracture location, percentage of shaft involvement, implant type, and multi-planar fixation (Table 2). Tables 3 and 4 show the effect of inadequate proximal and distal fixation according to location of fracture, with middle third (p = 0.045) and distal third (p = 0.031) diaphyseal fractures having a significantly higher rate of mechanical failure when fixed with less than 8 cortices of proximal fixation (Table 3). Additionally, distal third diaphyseal fractures also had a higher failure rate when fixed with less than 8 cortices of fixation distally (p = 0.046, Table 4).

Table 2 Radiographic and fixation characteristics in patients requiring revision for aseptic mechanical failure (Group 1), and those who did not (Group 2)
Table 3 Rate of aseptic mechanical failure vs no failure by ≥ 8 cortices of proximal fixation and fracture location
Table 4 Rate of aseptic mechanical failure vs no failure with by ≥ 8 cortices of distal fixation and fracture location

In order to determine which factors could be modeled as predictors of aseptic mechanical failure, a forward stepwise logistic regression analysis was performed using the two variables found to be significantly different between groups from our univariate analysis: (1) the presence of 8 or more cortices of proximal fixation and (2) the presence of 8 or more cortices of distal fixation. The forward stepwise regression demonstrated that inadequate proximal fixation was significantly associated with eightfold higher odds of aseptic failure (OR 7.96, confidence interval [CI] 1.59–39.7, p = 0.011). A minimum of 8 cortices of distal fixation was not found to be a significant predictor and was therefore removed from the model.

Discussion

With increasing rates of operative fixation of diaphyseal humeral fractures [2, 4], it is important to understand the ideal techniques to avoid failure and complications in patients undergoing operative fixation. To our knowledge, this is the first study to investigate risk factors for aseptic mechanical failure in humerus shaft plate fixation. We sought to develop a greater understanding of how different fracture characteristics may demand a deviation from historic guidelines, and how to technically optimize fixation. We observed an overall revision rate for mechanical failure of 13%. Our findings are consistent with previous reports which have observed revision rates ranging from 2 to 30% [8, 9].

The current study demonstrated a significant rate of aseptic mechanical failure in constructs with less than 8 cortices of proximal or distal fixation (p < 0.05). Previous reports have suggested a minimum of 6–8 cortices of fixation on either side of a humeral shaft fracture undergoing plate fixation [1, 10, 15]. Our results suggest that fixation constructs with 4 bicortical screws or more of fixation on either side of the fracture had lower failure rates than those fixed with 3 screws a side. Although we cannot comment on any potential advantage of having more than 4 screws a side, surgeons are routinely using more fixation, tailored to the specific fracture type, which can often include longer constructs or multiple plates. To our knowledge, there are no studies that directly compare 6 to 8 cortices of fixation in diaphyseal humerus fracture.

When comparing proximal and distal fixation, fixation of the proximal segment may be more critical in minimizing mechanical failure. We found inadequate proximal fixation, in the form of less than 8 cortices of fixation, to be a significant predictor of failure (p = 0.011), with an eight-fold increase in the rate of mechanical failure compared to constructs with 8 or more cortices of proximal fixation (OR 7.96). Secondary analysis of failure by fracture location (proximal, middle and distal third), was also conducted. Significantly higher rates of failure were seen in patients with middle (p = 0.45) and distal third fractures (p = 0.31) with less than 8 cortices of proximal fixation. Additionally, we observed that among those with middle third shaft fractures, failure occurred frequently in the form of proximal screw pull out (Fig. 1D, E). Table 5 demonstrates the mode of failure according to fracture location and fixation type. We hypothesize these findings are due to features unique to the proximal humerus. Firstly, the proximal humeral diaphysis is directly enacted on by multiple deforming forces including coronal and sagittal plane forces. In addition, it is uniquely subjected to rotational torque forces applied by the teres major and minor, infraspinatus, subscapularis, pectoralis major and latissimus dorsi [16]. Adequate fixation must overcome and withstand these multiplanar forces on the proximal segment. Secondly, it has been well documented that the proximal humeral cortical diaphysis thickness is variable and has decreased cortical thickness in osteoporotic bone [17]. As a result, special attention must be paid to the type and amount of fixation in that segment to avoid proximal screw pull out.

Fig. 1
figure 1

25-year-old female with a middle 1/3 diaphyseal, AO/OTA 12B2 humerus fracture (A). Patient received ORIF with Synthes narrow 4.5 mm LCDC plate, with immediate post-operative radiographs shown (B, C). Radiographs demonstrate unicortical fixation of one of the proximal screws, and 5 cortices of proximal fixation (C). Two years late the patient went on to mechanical failure with proximal screw pullout (D, E), requiring revision

Table 5 Fixation characteristics in patients requiring revision for aseptic mechanical failure

Regarding proximal third diaphyseal fractures, we failed to see a significant difference between those with 8 or more cortices of proximal fixation vs those with less than 8 cortices (p = 1.0). We attribute these equivocal findings to the preference of proximal humerus locking construct for fixation of these fractures, in which unicortical locking screws provide a mechanical advantage in a shorter proximal segment and allow for higher screw density. These constructs cannot be directly compared to non-locking plates used in more distal fractures. A higher rate of mechanical failure was also seen in distal third diaphyseal fractures with less than 8 cortices of distal fixation (p = 0.046). As distal fixation was not found to be a significant predictor of failure after regression analysis, the significance of this finding is indeterminant and we cannot draw conclusions regarding the number of cortices of distal fixation. Thus, 8 cortices of proximal fixation may be recommended, especially in middle and distal third diaphyseal fractures fixed with straight plates without proximal locking extension. It is important to ensure screws are truly bicortical if intended, as demonstrated by the patient in Fig. 1C, who went on to aseptic mechanical failure, with post-operative radiographs demonstrating that the screws were not fully engaged in the distal cortex.

There are several limitations to our study. The limited sample size may have resulted in a type II error. Although a large volume of patients underwent operative management of a diaphyseal humerus fracture during the study period, a significant proportion did not meet inclusion criteria. The principal reason for exclusion in the majority of cases was lack of follow-up to radiographic and clinical union. As a referral center for high volume trauma, many patients were either lost to follow-up, or transferred back to the referring centers for long-term follow-up after acute management of their injuries. As a result, we were also unable to account for patients who may have experienced fixation failure and presented to another institution for care. The remainder of patients who were eligible were followed until radiographic union and discharged from follow-up. We felt that this was adequate and did not pursue follow-up to one year, as our endpoint was defined as mechanical failure or discharge. The retrospective nature of the current study is also a limitation as it is subject to the inherent biases associated with this study design. Finally, we were unable to locate a comprehensive list of patient comorbidities as often these were not documented. Despite this, we did not find any significant demographic differences between the two groups, thereby improving the generalizability of our results.

Conclusion

Our results suggest, diaphyseal humerus fractures (AO/OTA 12) treated with ORIF may benefit from fixation with 8 or more cortices of fixation proximally and distally to avoid mechanical failure. Special attention should be paid to proximal fixation in middle and distal third humeral shaft fractures to mitigate proximal pull out and mechanical failure due to inadequate fixation. Further biomechanical and prospective comparative studies are required to confirm failure patterns and determine optimal fixation constructs for diaphyseal fractures of the humerus.

Availability of data and materials

Not applicable.

References

  1. Sarmiento A, Waddell JP, Latta LL. Diaphyseal humeral fractures: treatment options. Instr Course Lect. 2002;51:257–69.

    PubMed  Google Scholar 

  2. Schoch BS, Padegimas EM, Maltenfort M, Krieg J, Namdari S. Humeral shaft fractures: national trends in management. J Orthop Traumatol. 2017;18:259–63.

    Article  PubMed  PubMed Central  Google Scholar 

  3. Attum B, Obremskey W. Treatment of humeral shaft fractures: a critical analysis review. JBJS Rev. 2015;3(9).

  4. Gottschalk MB, Carpenter W, Hiza E, Reisman W, Roberson J. Humeral shaft fracture fixation: incidence rates and complications as reported by American Board of Orthopaedic Surgery Part II Candidates. J Bone Joint Surg Am. 2016;98:e71.

    Article  PubMed  Google Scholar 

  5. Olson JJ, Entezari V, Vallier HA. Risk factors for nonunion after traumatic humeral shaft fractures in adults. JSES Int. 2020;4(4):734–8.

    Article  PubMed  PubMed Central  Google Scholar 

  6. Hak DJ, Althausen P, Hazelwood SJ. Locked plate fixation of osteoporotic humeral shaft fractures: Are two locking screws per segment enough? J Orthop Trauma. 2010;24:207–11.

    Article  PubMed  Google Scholar 

  7. Kosmopoulos V, Nana AD. Dual plating of humeral shaft fractures: orthogonal plates biomechanically outperform side-by-side plates. Clin Orthop Relat Res. 2014;472:1310–7.

    Article  PubMed  Google Scholar 

  8. Denard A, Richards JE, Obremskey WT, Tucker MC, Floyd M, Herzog GA. Outcome of nonoperative vs operative treatment of humeral shaft fractures: a retrospective study of 213 patients. Orthopedics. 2010;33.

  9. Hosseini Khameneh SM, Abbasian M, Abrishamkarzadeh H, et al. Humeral shaft fracture: a randomized controlled trial of nonoperative versus operative management (plate fixation). Orthop Res Rev. 2019;11:141–7.

    PubMed  PubMed Central  Google Scholar 

  10. Tingstad EM, Wolinsky PR, Shyr Y, Johnson KD. Effect of immediate weightbearing on plated fractures of the humeral shaft. J Trauma. 2000;49:278–80.

    Article  CAS  PubMed  Google Scholar 

  11. Patel R, Neu CP, Curtiss S, Fyhrie DP, Yoo B. Crutch weightbearing on comminuted humeral shaft fractures: a biomechanical comparison of large versus small fragment fixation for humeral shaft fractures. J Orthop Trauma. 2011;25:300–5.

    Article  PubMed  Google Scholar 

  12. Singh AK, Narsaria N, Seth RR, Garg S. Plate osteosynthesis of fractures of the shaft of the humerus: comparison of limited contact dynamic compression plates and locking compression plates. J Orthop Traumatol. 2014;15:117–22.

    Article  PubMed  PubMed Central  Google Scholar 

  13. O’Toole RV, Andersen RC, Vesnovsky O, et al. Are locking screws advantageous with plate fixation of humeral shaft fractures? A biomechanical analysis of synthetic and cadaveric bone. J Orthop Trauma. 2008;22:709–15.

    Article  PubMed  Google Scholar 

  14. Karakasli A, Basci O, Ertem F, Sekik E, Havitcioglu H. Dual plating for fixation of humeral shaft fractures: a mechanical comparison of various combinations of plate lengths. Acta Orthop Traumatol Turc. 2016;50:432–6.

    Article  PubMed  PubMed Central  Google Scholar 

  15. Gautier E, Sommer C. Guidelines for the clinical application of the LCP. Injury. 2003;34(Suppl 2):B63-76.

    Article  PubMed  Google Scholar 

  16. Hik F, Ackland DC. The moment arms of the muscles spanning the glenohumeral joint: a systematic review. J Anat. 2019;234:1–15.

    Article  PubMed  Google Scholar 

  17. Tingart MJ, Apreleva M, von Stechow D, Zurakowski D, Warner JJ. The cortical thickness of the proximal humeral diaphysis predicts bone mineral density of the proximal humerus. J Bone Joint Surg Br. 2003;85:611–7.

    Article  PubMed  Google Scholar 

Download references

Funding

Not applicable.

Author information

Authors and Affiliations

Authors

Contributions

MM contributed to conceptualization, data curation, investigation formal analysis, methodology, writing—original drafting, writing—review and editing. JT contributed to formal analysis, data curation, writing—original draft, writing—review and editing. RH contributed to data curation, investigation. RRR contributed to writing—review and editing. US contributed to conceptualization, methodology, formal analysis, investigation, writing—review and editing, project administration. DN contributed to conceptualization, methodology, writing—review and editing, supervision, project administration.

Corresponding author

Correspondence to Manisha R. Mistry.

Ethics declarations

Ethics approval and consent to participate

Yes.

Consent for publication

Yes, all authors provide consent for publication.

Competing interests

All authors declare no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Mistry, M.R., Tat, J., Husain, R. et al. Inadequate proximal screw fixation increases risk of failure following plate fixation of diaphyseal humerus fractures. J Orthop Surg Res 18, 142 (2023). https://doi.org/10.1186/s13018-023-03566-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13018-023-03566-2

Keywords