Skip to main content
  • Systematic Review
  • Open access
  • Published:

Efficacy and safety of tension band wire versus plate for Mayo II olecranon fractures: a systematic review and meta-analysis

Abstract

Purpose

For olecranon fractures, the choice of tension band wire (TBW) or plate fixation has long been controversial. Therefore, this study aimed to evaluate the efficacy and safety of TBW and plate in the treatment of patients with Mayo II olecranon fractures by Meta-analysis.

Methods

PubMed, Embase, Cochrane, the Web of Science, China National Knowledge Infrastructure, Wanfang, and China Biomedical Database were searched for randomized controlled trials (RCTs) and cohort studies (CSs) where TBW was compared with plate for Mayo II olecranon fractures (OF). Subsequently, the data were extracted by two reviewers independently and were analysed via RevMan5.4.1. Besides, mean difference (MD), risk ratio (RR), and 95% confidence intervals (CIs) were calculated. Furthermore, Cochrane Risk of Bias Tool 2.0 and Newcastle–Ottawa Scale were adopted for assessing the risk of bias.

Results

A total of 1RCT and 10 CSs were included, when 449 cases were treated with TBW and 378 with plate. The plate has favourable postoperative long-term (≥ 1 year) functional score in MEPS (MD: − 3.06; 95% CI − 5.50 to 0.62; P = 0.01; I2 = 41%) and Dash score (MD: 2.32; 95% CI 1.91, 2.73; P < 0.00001; I2 = 0%), also carrying fewer complications (RR: 2.13; 95% CI 1.48, 3.08; P < 0.0001; I2 = 58%). Besides, there exists no significant difference in postoperative long-term (≥ 1 year) elbow flexion (MD: − 1.82°; 95% CI − 8.54, 4.90; P = 0.60; I2 = 71%) and extension deficits (MD: 1.52°; 95% CI − 0.38, 3.42; P = 0.12; I2 = 92%). Moreover, TBW is featured with a shorter operation time (MD = − 5.87 min; 95% CI − 7.93, − 3.82; P < 0.00001; I2 = 0) and less intraoperative bleeding (MD: − 5.33 ml; 95% CI − 8.15, − 2.52; P = 0.0002; I2 = 0). In terms of fracture healing time, it is still controversial. Furthermore, the subgroup analysis has revealed that for Mayo IIA OF, the plate has a better outcome in the long-term (≥ 1 year) postoperative MEPS, the Dash score, and the incidence of postoperative complications than TBW, while there is no significant difference in the long-term (≥ 1 year) postoperative elbow motion between two groups.

Conclusions

Plate has better efficacy and safety for Mayo II OF. Considering that few studies are included in the meta-analysis, more high-quality RCTs are still required to confirm these findings.

PROSPERO registration number: CRD42022313855.

Introduction

The olecranon fracture (OF) is a common upper limb fracture and often caused by direct violence against the elbow such as a fall or a car accident. Epidemiological investigations have revealed that the incidence of OF represents approximately 10% of upper limb fractures and 18% of forearm fractures [1]. Since the olecranon is a vital part of the elbow joint, its integrity and continuity directly influence the mobility and stability of the elbow joint. Some scholars have found that in all OFs, simple displaced transverse fractures are the most common, among which approximately up to 85% belong to Mayo II OF [2].

At present, the common internal fixation methods for the treatment of the OF include tension band fixation, K-wire/screw tension band fixation, intramedullary nail fixation, and plate fixation [2,3,4]. However, there is no uniform internal fixation option for Mayo II OF. The AO Fracture Internal Association recommends tension band wire (TBW) fixation for Mayo IIA OF, and plate fixation for Mayo IIB OF [5]. However, in the actual treatment process, as there are considerable differences in fractures, it is difficult to strictly follow the recommended protocol. In such case, the unified treatment standard for Mayo II OF is still in dispute.

As typical treatments for Mayo II OF, TBW and plate have different fixation principles. TBW refers to employing two parallel Kirschner wires to fix the distal and proximal ends of the fracture and using a ‘figure of 8’ loop to convert the extensor forces of the triceps muscle into compressive forces along the articular surface. Comparatively, plate refers to attaching the metal plate to the fracture fragments with screws to bridge the fracture gap and facilitate fracture healing [2, 6].

Some scholars consider that there is no obvious difference in the TBW between treating simple and crushed OF, and thus, it can be used as the gold standard for treating the OF [7, 8]. However, insufficient stability of Kirschner wire causes more complications from TBW fixation (soft tissue stimulation, failure of fixation, etc.), and thus, a more stable plate fixation substitution was proposed by Ren et al. [9]. The latest systematic review of OF treatment found that there was no significant difference in the clinical efficacy of the TBW and plate, but since there were few included studies and the fracture classification was not defined, the conclusions have some limitations [10]. Given the current controversy over the treatment of Mayo II OF, we conducted this systematic review and meta-analysis to investigate the efficacy and safety of TBW versus plate for Mayo II OF.

Methods

This meta-analysis was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. The study was registered in the International Prospective Register of Systematic Reviews (PROSPERO) database (registry no. CRD42022313855).

Search strategy

A comprehensive search in electronic databases (PubMed, Cochrane, Embase, Web of Science, China National Knowledge Infrastructure, Wanfang Digital Periodicals, and the Chinese Biomedical Literature) was conducted on 28 February 2022 for studies that compared plate with TBW for OF. Here, it should be noted that the search syntax is described in Additional file 1.

Selection criteria

Study design

Randomized controlled trials (RCTs) and retrospective or prospective cohort studies (CSs) were considered for inclusion.

Participants

Patients with Mayo II OF were included. Children or patients with pathologic fractures were excluded.

Intervention or exposure and control

RCTs or CSs evaluating the efficacy and safety of TBW versus plate for OF were included. A minimal follow-up duration of 6 months was required. Each group should have no less than 10 patients. The surgical procedures were unrestricted.

Outcomes

The primary outcome measures included the postoperative Mayo Elbow Performance Score (MEPS), postoperative Disabilities of the Arm, Shoulder and Hand (Dash) score, complications, elbow flexion, and elbow extension deficits. The second outcome measures contained intraoperative bleeding, fracture healing time, and operation time.

Literature screening

The literature searched from the databases was imported into the Endnote X9 software [11]. After removing the duplicate literature, two reviewers (Y.J and A.L) deleted literature that did not satisfy the inclusion and exclusion criteria based on the title and abstract individually. Besides, the full texts of the remaining literature were reviewed to identify the eligible studies. Disagreement was solved by consensus with a third reviewer (J.Z).

Data extraction

Two authors (W.Y and J.C) extracted the information independently and finally cross-checked it. The extraction involved the name of the first author, year of publication, country, type of study, intervention, the sample size of two groups, the ratio of males to females, mean age, follow-up time, fracture type, and outcome index. If the information is incomplete, they attempted to contact the author of the original literature.

Quality assessment of included studies

Two authors (Y.J and T.G) evaluated the literature independently. Cochrane Risk of Bias Tool 2.0 was applied to evaluate the quality of the RCTs [12], and the NOS score was employed to assess the quality of the CSs [13]. The disagreements were resolved by consulting with a third evaluator (J.Z.).

Statistical analysis

Meta-analysis was performed using RevMan statistical software version 5.4.1 (Cochrane Collaboration). For the dichotomous variables, the risk ratio (RR) and 95% confidence intervals (CIs) were estimated. However, for the continuous variables, the pooled effect was presented as the mean difference (MD) and 95% CIs. P < 0.05 indicated a statistically significant difference between the 2 groups. Apart from that, the I2 statistic and P value were used to evaluate heterogeneity, while a random-effects model was applied when the statistical heterogeneity was high (P ≤ 0.10 or I2 ≥ 50%) [14]. Otherwise, a fixed-effects model was involved (P > 0.10 and I2 < 50%). If possible, subgroup analyses based on age, race, fracture classification, study type, etc., were made when the heterogeneity was high. Publication bias was assessed by the Eggers test using Stata15.0 when the meta-analysis included > 10 studies. Moreover, a narrative description was provided if meta-analysis was infeasible.

Results

Literature search

Among the 915 citations identified in the search, we excluded 277 duplicates using Endnote X9 software. A further 586 citations were excluded after the title and abstract screening in line with the selection criteria. Then, 41 articles were further excluded because of unqualified fracture classification, insufficient following time and no data on the outcome of interest. Finally, 11 articles, namely 1 RCT and 10 CSs, were involved [15,16,17,18,19,20,21,22,23,24]. Figure 1 presents the flow chart of the literature search and study selection.

Fig. 1
figure 1

PRISMA flow chart of the literature search

Characteristics and qualifications of included studies

The characteristics of all eleven included studies were summarized and are shown in Table 1. Specifically, 1 RCT and 10 CSs involved 827 patients with OFs (449 patients in TBW, 378 patients in plate). All of them were published between 2014 and 2021. The included RCT had a moderate methodological quality according to the Cochrane Risk of Bias Tool 2.0 [17] (Additional file 2), while the included 10 CSs had moderate-to-high methodological qualities based on the Newcastle–Ottawa Scale, because the total scores were higher than five stars (Table 2).

Table 1 Characteristics of included studies
Table 2 Newcastle–Ottawa Scale scores for included cohort studies

Primary outcomes

MEPS

Seven studies reported postoperative MEPS (one RCT and six CSs) [15,16,17,18,19, 23, 25]. Two CSs showed no statistically significant differences in the postoperative MEPS between plate and TBW groups of the Mayo II OF (Qiu (MD = − 1.80; 95% CI − 4.68, 1.08; P = 0.22) [19] and Tarallo (MD = − 1.80; 95% CI − 6.73 to 3.13; P = 0.47) [23]). However, the scores of the plate group were better than those of the TBW group in both studies. They were not included in the meta-analysis for unmentioned measuring time. The other five studies compared the long-term efficacy of 1 year or more, while two CSs compared the efficacy of the Mayo II OF [15, 16]. Besides, two CSs [18, 25] and one RCT [17] compared the efficacy of the Mayo IIA OF. A better long-term MEPS was found in the plate group (MD = − 3.06; 95% CI − 5.50, 0.62; P = 0.01; I2 = 41%). To further lower the heterogeneity, we performed a subgroup analysis of studies with different fracture classifications. Furthermore, the estimates in the Mayo II OF (MD = − 0.63; 95% CI − 4.76, 3.49; P = 0.76; I2 = 41%) and the Mayo IIA OF (MD = − 4.48; 95% CI − 6.77, − 2.20; P = 0.0001; I2 = 0%) were similar (test for subgroup difference: P = 0.11; I2 = 60.9%) (Fig. 2).

Fig. 2
figure 2

Forest plot of the postoperative MEPS after TBW versus plate for olecranon fractures

Dash scores

Five studies reported postoperative Dash score (one RCT and four CSs) [17, 18, 22, 23, 25], while two CSs examined the Mayo II OF (Tarallo (MD: 1.70; 95% CI − 3.75, 7.15; P = 0.54) [23]) and the Mayo IIA OF (Schliemann (MD: 1.50; 95% CI − 7.28, 10.28; P = 0.74) [22]), respectively. There existed no statistical difference between both treatment groups, while the scores of the plate group were better than those of the TBW group in both studies. They were not included in the meta-analysis for unmentioned measuring time. In addition, two CSs [18, 25] and one RCT [17] compared the long-term efficacy of the Mayo IIA OF for 1 year or more. Furthermore, the plate group showed better functional scores (MD: 2.32; 95% CI 1.91, 2.73; P < 0.00001; I2 = 0%) (Fig. 3).

Fig. 3
figure 3

Forest plot of the postoperative Dash score after TBW versus plate for olecranon fractures

Elbow flexion

Six studies reported postoperative elbow flexion (one RCT and five CSs) [15,16,17, 19, 20, 22]. Three CSs examined the Mayo II OF (Qiu (MD: − 1.0°; 95% CI − 6.59, 4.59; P = 0.73)) [19] and the Mayo IIA OF (Schliemann (MD: − 3.00°; 95% CI − 7.75, 1.75; P = 0.22) [22]; Tan (131° vs 117°; P = 0.17) [20]), respectively. No statistical difference was found between both treatment groups, while the plate group was featured with the better elbow flexion in two studies [19, 22]. They were not included in the meta-analysis for unmentioned measuring time or unavailable data. The other three studies compared the long-term flexion of 1 year or more, while two CSs compared the flexion of the Mayo II OF [15, 16]. Besides, one RCT compared the flexion of the Mayo IIA OF [17]. There was no difference in long-term elbow flexion between both groups (MD: − 1.82°; 95% CI − 8.54, 4.90; P = 0.60; I2 = 71%). To further reduce the heterogeneity, we conducted a subgroup analysis of studies with different fracture classifications. Moreover, the estimates of the Mayo II OF (MD: − 5.26°; 95% CI − 9.14, − 1.39; P = 0.008; I2 = 0) differed from those of the Mayo IIA OF (MD: 6.00°; 95% CI − 1.79, 13.79; P = 0.13; I2 = not applicable) (the test for subgroup difference: P = 0.01; I2 = 84.5%) (Fig. 4).

Fig. 4
figure 4

Forest plot of postoperative elbow flexion after TBW versus plate for olecranon fractures

Elbow extension deficit

Four CSs reported postoperative elbow extension deficit, while two CSs examined the Mayo II OF (Tarallo (MD: 1.90°; 95% CI − 2.17, 5.97; P = 0.36) [23]) and the Mayo IIA OF (Schliemann (MD: − 1.50°; 95% CI − 6.88, 3.88; P = 0.58) [22]), respectively. No statistical difference was observed between both treatment groups. They were not included in the meta-analysis for unmentioned measuring time. The other two studies compared the long-term elbow extension deficit of the Mayo IIA OF of 1 year or more [18, 25]. Furthermore, there was no difference in postoperative elbow extension deficit between both groups (MD: 1.52°; 95% CI − 0.38, 3.42; P = 0.12; I2 = 92%) (Fig. 5).

Fig. 5
figure 5

Forest plot of the postoperative elbow extension deficit after TBW versus plate for olecranon fractures

Complications

The complications were reported in all studies [15,16,17,18,19,20, 22,23,24,25,26]. Total complications occurred in 44.5% of patients treated with TBW versus 19.9% in the plate group. There was a lower risk of total complications in patients treated with plate (RR 2.13; 95% CI 1.48, 3.08; P < 0.0001; I2 = 58%). To further lower the heterogeneity, we performed a subgroup analysis of studies with different fracture classifications. Besides, the estimates were similar in the Mayo II OF (RR 2.06; 95% CI 0.99, 4.28; I2 = 68%) and the Mayo IIA OF (RR 2.24; 95% CI 1.44, 3.50; I2 = 55%) (the test for subgroup difference: P = 0.84; I2 = 0%) (Fig. 6). Egger’s test (P = 0.178) presented no publication bias for the complications (Fig. 7).

Fig. 6
figure 6

Forest plot of complications after TBW versus plate for olecranon fractures

Fig. 7
figure 7

Egger’s test of complications between TBW and plate

A further meta-analysis of different complications was conducted. Then, it was found that the risk of implant failure/displacement, implant removal, and implant stimulation in the TBW group was higher than that of the plate group. Moreover, no difference was detected in the risk of other complications. Detailed data are illustrated in Table 3.

Table 3 Comparisons of the incidence of complications between TBW and plate

Secondary outcomes

Operation time

Two CSs reported operation time [15, 16], and all examined the Mayo II OF. The TBW group had a shorter operation time (MD = − 5.87 min; 95% CI − 7.93, − 3.82; P < 0.00001; I2 = 0) (Fig. 8).

Fig. 8
figure 8

Forest plot of operation time after TBW versus plate for olecranon fractures

Intraoperative bleeding

Two CSs reported intraoperative bleeding [15, 16], and all examined the Mayo IIOF. The TBW group had less intraoperative bleeding (MD = − 5.33 ml; 95% CI − 8.15 to − 2.52; P = 0.0002; I2 = 0) (Fig. 9).

Fig. 9
figure 9

Forest plot of intraoperative bleeding after TBW versus plate for olecranon fractures

Fracture healing time

Three CSs reported fracture healing time [15, 16, 20]. One CS showed that TBW had a shorter fracture healing time for the Mayo IIA OF (11w VS 15w; P < 0.01) [20], while the other two revealed that there existed no difference in fracture healing time between both groups for the Mayo II OF (MD = 0.08w; 95% CI − 0.55 to 0.71; P = 0.80; I2 = 0) (Fig. 10).

Fig. 10
figure 10

Forest plot of fracture healing time after TBW versus plate for olecranon fractures

Discussion

In this study, we identified 1 RCT and 10 CSs to evaluate the efficacy and safety of TBW versus plate in the treatment of patients with Mayo II olecranon fractures. According to the results, plate has a favourable postoperative long-term (≥ 1 year) functional score and carries fewer complications. Though no significant differences were observed in postoperative long-term (≥ 1 year) elbow motion, after comprehensive analysis, we believe that plate has a better efficacy and safety for Mayo II olecranon fractures.

As a classic regimen for the OF, TBW has been praised by a large number of clinicians [8, 27, 28]. In virtue TBW does not require extensive dissection of the soft tissue, it maximizes the protection of the blood flow to the fracture site and shortens the operation time. However, due to the lack of stability of Kirschner wire fixation and the differences in the TBW fixation skill of different doctors, it is challenging for the technique to achieve the desired effect, and the TBW fixation is featured with a high risk of internal fixation shifting/failure [29, 30], which was also confirmed in the present study, where the risk of implant failure/displacement in the TBW group was much higher than that in the plate group.

Plate possesses strong and stable fixation properties and can provide long-lasting and effective fracture reduction. Particularly for the olecranon, the plate fixation can better achieve the biological adhesion to the bone, and thus, it is capable of performing effective fixation of various types of fractures [31, 32]. In addition, biomechanical studies also confirmed that plate fixation had less fracture displacement than TBW fixation for the simple OF mode [33, 34]. However, plate fixation also has some deficiencies including large surgical incision, wide soft tissue dissection, and possible intraoperative injury of triceps muscle attachment points [9], which may lead to slow fracture healing, limited elbow joint movement, infection, and other conditions. Nevertheless, in the current research, no supporting evidence was provided. By contrast, plate fixation had fewer complications such as implant failure/displacement and implant stimulation, which is consistent with the conclusions from two previous studies [9, 35], which is sufficient to demonstrate the safety of the plate fixation.

As for efficacy, it was found that for the Mayo II OF, plate fixation obtained a better postoperative long-term (≥ 1 year) functional score. However, in other studies, no difference was found in this respect [9, 35]. The reason may be attributed to the difference to the classification of fractures. Because the classification of fractures has a direct impact on the outcome [19], the comparison of the same type of fracture reduces the heterogeneity and makes the outcome more credible. In terms of elbow motion, no statistical differences were found in elbow flexion and elbow extension deficit. Considering the high heterogeneity of the results, we performed a subgroup analysis on the fracture classification of elbow flexion. A better elbow flexion was found in Mayo II OF subgroup. The difference in outcomes between subgroups may be associated with the presence of type Mayo 2B fractures, for which plate may have a better efficacy. For elbow extension deficit, a subgroup analysis could not be performed with only two studies, but pooled block tended to PF if ignoring the heterogeneity. In conclusion, we believe that plate exerts a better clinical efficacy for Mayo II OF.

For the secondary outcomes, inconsistent conclusions were obtained on the time of fracture healing, which may be related to the fracture subtype, and the presence of type Mayo IIB OF may prolong the fracture healing time of TBW fixation. Although plate fixation showed a worse outcome in terms of the amount of intraoperative bleeding, the difference in the average amount of intraoperative bleeding between the two methods is less than 10 ml, which is not significant in clinical practice. Concerning the operation time, plate takes more time due to the complexity of the operation. Besides, the biggest deficiency of plate fixation lies in the high cost of surgery, which will bring greater economic burden to patients. This is also the main reason why most clinicians prefer TBW fixation. However, the study of Andrew D. Duckworth and A. J. Powell demonstrated that the cost of the TBW fixation was close to or even beyond that of the plate fixation because of the higher rate of revision [17, 26], indicating that the strong and reliable fixation is more significant for clinical outcomes. In addition, Edward M. DelSole discovered that the one-third tubular construct can achieve the same clinical efficacy as locking plate and reduce the cost of approximately $1263.5 [36], implying that choosing the right plate can also decrease the economic pressure of patients to some extent.

The most interesting finding of this study was the better long-term (≥ 1 year) functional scores in both the postoperative MEPS and the Dash score in the plate group for the Mayo IIA OF, which indicated that plate fixation may have better long-term (≥ 1 year) efficacy for the Mayo IIA OF, showing no difference in Ren Yiming’s study [9]. Furthermore, no significant difference is observed in elbow flexion and extension deficits for the Mayo IIA OF. As for complications, the Mayo IIA OF displayed a similar outcome to the Mayo II OF, and both of them had a lower risk of complication rate, demonstrating the advantage of plate over TBW in the treatment of the Mayo IIA OF.

Limitations

Firstly, the studies included in this study are mainly retrospective cohorts, with certain recall bias. Secondly, there are no independent studies of Mayo IIB fractures. Further analysis of such subtypes is impossible. Thirdly, in this paper, only the TBW and plate fixation are compared, and the results are not applicable to other modified tension band fixation schemes. Fourthly, the results should be interpreted cautiously due to the small number and heterogeneity of the included studies.

Conclusion

Based on the results of our study, plate fixation has better long-term (≥ 1 year) postoperative MEPS and Dash scores in the Mayo II OF and features a lower risk of complications. Besides, the elbow motion is not significantly different between TBW and plate. Moreover, TBW costs a shorter operation time and less intraoperative bleeding. However, as for the fracture healing time, the results are still controversial between the two groups. Furthermore, for the Mayo IIA OF, the same conclusion in the functional score, elbow motion, and complication can be obtained.

In brief, plate has better efficacy and safety than TBW for Mayo II OF. More high-quality RCTs are still required to confirm the present findings.

Abbreviations

TBW:

Tension band wire

OF:

Olecranon fracture

MEPS:

Mayo Elbow Performance Score

Dash:

Disabilities of the Arm, Shoulder and Hand

CIs:

Confidence interval

RR:

Risk ratio

MD:

Mean difference

References

  1. Duckworth AD, Clement ND, Aitken SA, Court-Brown CM, McQueen MM. The epidemiology of fractures of the proximal ulna. Injury. 2012;43(3):343–6. https://doi.org/10.1016/j.injury.2011.10.017.

    Article  PubMed  Google Scholar 

  2. Baecher N, Edwards S. Olecranon fractures. J Hand Surg Am. 2013;38(3):593–604. https://doi.org/10.1016/j.jhsa.2012.12.036.

    Article  PubMed  Google Scholar 

  3. den Hamer A, Heusinkveld M, Traa W, Oomen P, Oliva F, Del Buono A, Maffulli N. Current techniques for management of transverse displaced olecranon fractures. Muscles Ligaments Tendons J. 2015;5(2):129–40.

    Article  Google Scholar 

  4. Veillette CJ, Steinmann SP. Olecranon fractures. Orthop Clin N Am. 2008;39(2):229–vii. https://doi.org/10.1016/j.ocl.2008.01.002.

    Article  Google Scholar 

  5. Ruedi TP, Buckley RE, Moran CG. AO principles of fracture management. Spec Fract. 2000;2:628–33.

    Google Scholar 

  6. Matar HE, Ali AA, Buckley S, Garlick NI, Atkinson HD. Surgical interventions for treating fractures of the olecranon in adults. Cochrane Database Syst Rev. 2014;2014(11):CD010144. https://doi.org/10.1002/14651858.CD010144.pub2.

    Article  PubMed Central  Google Scholar 

  7. Chalidis BE, Sachinis NC, Samoladas EP, Dimitriou CG, Pournaras JD. Is tension band wiring technique the “gold standard” for the treatment of olecranon fractures? A long term functional outcome study. J Orthop Surg Res. 2008;3:9. https://doi.org/10.1186/1749-799X-3-9.

    Article  PubMed  PubMed Central  Google Scholar 

  8. Terstappen ALE, Joosse P, van Dijke CF, Mirck B, van den Brand JGH. Tension band wiring provides excellent patient-reported long-term results for both comminuted and simple displaced olecranon fractures. J Orthop Trauma. 2020;34(7):e239–44. https://doi.org/10.1097/BOT.0000000000001728.

    Article  PubMed  Google Scholar 

  9. Ren YM, Qiao HY, Wei ZJ, Lin W, Fan BY, Liu J, Li A, Kang Y, Liu S, Hao Y, Zhou XH, Feng SQ. Efficacy and safety of tension band wiring versus plate fixation in olecranon fractures: a systematic review and meta-analysis. J Orthop Surg Res. 2016;11(1):137. https://doi.org/10.1186/s13018-016-0465-z.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Rantalaiho IK, Miikkulainen AE, Laaksonen IE, Äärimaa VO, Laimi KA. Treatment of displaced olecranon fractures: a systematic review. Scand J Surg. 2021;110(1):13–21. https://doi.org/10.1177/1457496919893599.

    Article  CAS  PubMed  Google Scholar 

  11. Panagopoulos A, Solou K, Tatani I, et al. What is the optimal surgical treatment for Neer type IIB (IIC) distal clavicle fractures? A systematic review and meta-analysis. J Orthop Surg Res. 2022;17(1):215. https://doi.org/10.1186/s13018-022-03108-2.

    Article  PubMed  PubMed Central  Google Scholar 

  12. Ma LL, Wang YY, Yang ZH, Huang D, Weng H, Zeng XT. Methodological quality (risk of bias) assessment tools for primary and secondary medical studies: what are they and which is better? Mil Med Res. 2020;7(1):7. https://doi.org/10.1186/s40779-020-00238-8.

    Article  PubMed  PubMed Central  Google Scholar 

  13. Stang A. Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in meta-analyses. Eur J Epidemiol. 2010;25(9):603–5. https://doi.org/10.1007/s10654-010-9491-z.

    Article  PubMed  Google Scholar 

  14. Lawati KA, Sharif S, Maqbali SA, Rimawi HA, Petrosoniak A, Belley-Cote EP, Sharma SV, Morgenstern J, Fernando SM, Owen JJ, Zeller M, Quinlan D, Alhazzani W, Rochwerg B. Efficacy and safety of tranexamic acid in acute traumatic brain injury: a systematic review and meta-analysis of randomized-controlled trials. Intensive Care Med. 2021;47(1):14–27. https://doi.org/10.1007/s00134-020-06279-w.

    Article  CAS  PubMed  Google Scholar 

  15. Lu Y, Han K, Wang Q, Ma T, Sun L, Lu DM, Li M, Ren C, Xue HZ, Duan N, Li Z, Zhang K. Comparison of clinical effect between locking proximal plate and tension-band wire in treatment of olecranon fracture. Chin J Bone Joint Injury. 2020;35(07):697–9.

    CAS  Google Scholar 

  16. Gong SH, Shi XB, Bao CL. Comparison of tension band wire versus anatomic locking plate for olecranon fracture. Orthop J Chin. 2018;26(06):491–4.

    Google Scholar 

  17. Duckworth AD, Clement ND, White TO, Court-Brown CM, McQueen MM. Plate versus tension-band wire fixation for olecranon fractures: a prospective randomized trial. J Bone Joint Surg Am. 2017;99(15):1261–73. https://doi.org/10.2106/JBJS.16.00773.

    Article  PubMed  Google Scholar 

  18. Çağlar C, Akçaalan S, Özaslan Hİ, Yağar H, Uğurlu M. Comparison of tension band wiring and plate fixation in Mayo type 2A olecranon fractures. Jt Dis Relat Surg. 2021;32(1):85–92. https://doi.org/10.5606/ehc.2021.75812.

    Article  PubMed  PubMed Central  Google Scholar 

  19. Qiu L, Li Y, Wu H, Chen R, Zhang Z, Wang X, Huang Y. More metalwork removals in patients with olecranon fracture treated by tension band wiring than plate fixation—a propensity score matching analysis. BMC Musculoskelet Disord. 2021;22(1):692. https://doi.org/10.1186/s12891-021-04559-0.

    Article  PubMed  PubMed Central  Google Scholar 

  20. Tan BYJ, Pereira MJ, Ng J, Kwek EBK. The ideal implant for Mayo 2A olecranon fractures? An economic evaluation. J Shoulder Elbow Surg. 2020;29(11):2347–52. https://doi.org/10.1016/j.jse.2020.05.035.

    Article  PubMed  Google Scholar 

  21. Powell AJ, Farhan-Alanie OM, McGraw IWW. Tension band wiring versus locking plate fixation for simple, two-part Mayo 2A olecranon fractures: a comparison of post-operative outcomes, complications, reoperations and economics. Musculoskelet Surg. 2019;103(2):155–60. https://doi.org/10.1007/s12306-018-0556-6.

    Article  CAS  PubMed  Google Scholar 

  22. Schliemann B, Raschke MJ, Groene P, Weimann A, Wähnert D, Lenschow S, Kösters C. Comparison of tension band wiring and precontoured locking compression plate fixation in Mayo type IIA olecranon fractures. Acta Orthop Belg. 2014;80(1):106–11.

    PubMed  Google Scholar 

  23. Tarallo L, Mugnai R, Adani R, Capra F, Zambianchi F, Catani F. Simple and comminuted displaced olecranon fractures: a clinical comparison between tension band wiring and plate fixation techniques. Arch Orthop Trauma Surg. 2014;134(8):1107–14. https://doi.org/10.1007/s00402-014-2021-9.

    Article  PubMed  Google Scholar 

  24. Liñán-Padilla A, Cáceres-Sánchez L. Type II olecranon fractures in patients over 65. Tension band or pre-formed plate? Analysis and results. Fracturas de olécranon tipo ii en mayores de 65 años. ¿Banda a tensión o placa preformada? Análisis y resultados. Rev Esp Cir Ortop Traumatol. 2017;61(5):339–42. https://doi.org/10.1016/j.recot.2017.04.005.

    Article  PubMed  Google Scholar 

  25. Wang Z, Wang A. Comparison of effect of tension band wiring versus plate fixation in the treatment of MayoIIA olecranon fracture. Chin J Pract Med. 2021;48(20):60–2.

    Google Scholar 

  26. Powell AJ, Farhan-Alanie OM, Bryceland JK, Nunn T. The treatment of olecranon fractures in adults. Musculoskelet Surg. 2017;101(1):1–9. https://doi.org/10.1007/s12306-016-0449-5.

    Article  CAS  PubMed  Google Scholar 

  27. Okamoto M, Namba J, Kuriyama K, Miyamura S, Yokoi H, Yamamoto K. Surgical technique in tension band wiring method for selected comminuted olecranon fractures. Eur J Orthop Surg Traumatol. 2020;30(2):237–42. https://doi.org/10.1007/s00590-019-02551-y.

    Article  PubMed  Google Scholar 

  28. Lee SH, Kim MB, Lee YH. Simple osteotomy site repair method for the trans-olecranon approach: tension band wiring with ring pins. J Hand Surg Asian Pac. 2021;26(4):571–9. https://doi.org/10.1142/S2424835521500545.

    Article  Google Scholar 

  29. Claessen FMAP, van den Bekerom MPJ, van Dijk CN, Goslings JC, Kerkhoffs GMMJ, Doornberg JN. Shoulder elbow platform. Tension band wiring for simple olecranon fractures: evaluation of surgical technique. J Orthop Traumatol. 2017;18(3):275–81. https://doi.org/10.1007/s10195-017-0450-2.

    Article  PubMed  PubMed Central  Google Scholar 

  30. Schneider MM, Nowak TE, Bastian L, Katthagen JC, Isenberg J, Rommens PM, Müller LP, Burkhart KJ. Tension band wiring in olecranon fractures: the myth of technical simplicity and osteosynthetical perfection. Int Orthop. 2014;38(4):847–55. https://doi.org/10.1007/s00264-013-2208-7.

    Article  PubMed  Google Scholar 

  31. Wagner FC, Jaeger M, Friebis C, Maier D, Ophoven C, Yilmaz T, Südkamp NP, Reising K. Low-profile double plating of unstable osteoporotic olecranon fractures: a biomechanical comparative study. J Shoulder Elbow Surg. 2021;30(7):1519–26. https://doi.org/10.1016/j.jse.2020.11.008.

    Article  PubMed  Google Scholar 

  32. Wagner FC, Konstantinidis L, Hohloch N, Hohloch L, Suedkamp NP, Reising K. Biomechanical evaluation of two innovative locking implants for comminuted olecranon fractures under high-cycle loading conditions. Injury. 2015;46(6):985–9. https://doi.org/10.1016/j.injury.2015.02.010.

    Article  CAS  PubMed  Google Scholar 

  33. Priambudi S, Ramawan E. Comparison of biomechanical stability between tensionband wiringfixation and post-osteotomyolecranonchevronhook plate. Medico-Legal Update. 2020;20(2):309–13.

    Google Scholar 

  34. Gruszka D, Arand C, Nowak T, Dietz SO, Wagner D, Rommens P. Olecranon tension plating or olecranon tension band wiring? A comparative biomechanical study. Int Orthop. 2015;39(5):955–60. https://doi.org/10.1007/s00264-015-2703-0.

    Article  PubMed  Google Scholar 

  35. Koziarz A, Woolnough T, Oitment C, Nath S, Johal H. Surgical management for olecranon fractures in adults: a systematic review and meta-analysis. Orthopedics. 2019;42(2):75–82. https://doi.org/10.3928/01477447-20190221-03.

    Article  PubMed  Google Scholar 

  36. DelSole EM, Egol KA, Tejwani NC. Construct choice for the treatment of displaced, comminuted olecranon fractures: are locked plates cost effective? Iowa Orthop J. 2016;36:59–63.

    PubMed  PubMed Central  Google Scholar 

Download references

Funding

This study was supported by a grant from the National Natural Science Foundation of China (81873316).

Author information

Authors and Affiliations

Authors

Contributions

YJ, AL, and JZ designed this systematic review. YJ and AL searched the database. WY and JC extracted the data. YJ and TG did the assessment of methodological quality and risk of bias. JZ provided consultation and Quality control. YJ and AL did the data analysis and wrote the paper. AL and JZ revised the manuscript; JY and AL contributed equally to this work. All authors read and approved the final manuscript.

Corresponding authors

Correspondence to Aifeng Liu or Jingbo Zhai.

Ethics declarations

Ethics approval and consent to participate

This article does not contain any studies with human participants or animals performed by any of the authors.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Additional file 1

. Search Strategy (Pubmed).

Additional file 2

. Table S1. Revised Cochrane risk of bias tool for randomized controlled trial (RoB2.0). Figure S1. Risk of bias summary in 1 RCT.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Jia, Y., Liu, A., Guo, T. et al. Efficacy and safety of tension band wire versus plate for Mayo II olecranon fractures: a systematic review and meta-analysis. J Orthop Surg Res 17, 373 (2022). https://doi.org/10.1186/s13018-022-03262-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13018-022-03262-7

Keywords