Comparison of hook plate versus T-plate in the treatment of Neer type II distal clavicle fractures: a prospective matched comparative cohort study

Abstract

Background

This study aimed to compare the clinical and radiological outcomes of distal clavicle fracture fixation with a hook plate versus the standard non-locking T-plate for unstable Neer type II fractures.

Methods

A prospective matched cohort study including two groups of hook plates and T-plates fixation was conducted in our two tertiary trauma centers. Patients with distal clavicle fractures Neer type II were assessed for union and the Constant-Murley score (CMS) at 1-, 3-, and 6-month follow-ups. Inadequate radiographic consolidation > 6 months after surgery was defined as non-union. Subscales of CMSpain, CMSactivities of daily living, CMSrange of motion (ROM), and CMSstrength were also compared between groups. According to recommendations, the implant was removed after union confirmation in the hook plate at a planned second surgery.

Results

Sixty consecutive patients were enrolled: 30 in the T-plate group and 30 in the hook plate group. CMS showed similar functional outcomes for T-plates and hook plates at all follow-ups (Month 6: 92.0 vs. 91.7, P = 0.45). However, on the month 1 follow-up, the T-plate group scored higher than the hook plate group for ROM and pain (CMSpain = 13.0 vs. 12.3, P = 0.03; CMSROM = 35.2 vs. 33.2, P = 0.002). Despite this, Pain, ROM, and other CMS domains were comparable between groups (P > 0.05). The mean time to union was 2.5 + 1.4 months for the T-plate group and 2.3 + 1.6 months for the hook plate group (P = 0.44). There was one fixation failure in each group and one periprosthetic fracture in the hook plate group (two revisions for the hook plates and one for T-plates, P = 1.00). Non-union and other complications were not observed.

Conclusion

Both surgical approaches resulted in full recovery and good function. However, in the hook plate group ROM and pain scores were lower at 1 month. Standard non-locking T-plates are a viable alternative to hook plates with low cost and promising outcomes for treating displaced distal clavicle fractures.

Introduction

Distal clavicle fractures are among the most common injuries in adults, accounting for 2.6–5% of all fractures and 21% of clavicle fractures [1,2,3,4,5]. It constitutes up to 45% of clavicle non-unions and can result in severe disability if not treated adequately; therefore, unstable distal clavicle fractures should receive appropriate surgical treatment [2, 6, 7]. Distal clavicle is anatomically made of metaphyseal bone with a small distal fragment. This makes it difficult to achieve stable fixation and early motion [8]. Several surgical devices have been used to fix this fracture in recent years, including locking anatomical plates, hook plates, T-shape plates, trans-acromial pinning, double plates, and tension band wiring. However, there is no gold standard yet [2, 9,10,11,12,13].

Hook plates are widely used and help create a stable lever that elevates the acromion and pushes the clavicle downward to hold it firmly in place, negating movement of the broken part while not interfering with clavicle rotation [12, 13]. Hook plate fixation is a suitable method with an acceptable union rate when the remaining distal clavicle fragment is small and cannot be adequately fixed [11]. This method has disadvantages, including the need to remove the implant to achieve full ROM and eliminate the unpleasant feeling of having an external device attached [14]. Also, using the subacromial space for clavicular hook plating may cause adverse effects, such as rotator cuff tear and subacromial impingement, causing pain and stiffness of the shoulder that takes time to subside [12, 14,15,16,17,18].

Another potential method is fixing with T-plates, a 3.5-mm low-profile titanium plate, introduced by Kalamaras et al. in 2008 [8, 19]. T-plate fixation has demonstrated high union rates, good function, and low complication rates [19,20,21,22]. The plate design enables the insertion of three screws into the small distal fragment, providing stability [22]. A lack of evidence exists for a direct comparison between T-plate and Hook fixation of a distal clavicle fracture [11].

Controversy still exists regarding the effectiveness and complications of surgical treatment options for unstable distal clavicle fractures. This study aimed to compare the clinical and radiological outcomes of unstable Neer type II distal clavicle fracture fixation with a non-locking hook plate versus a standard non-locking T-plate. We hypothesized that the T-plate fixation has comparable union rates and functional outcomes at a six-month follow-up.

Methods

Study design and setting

Between March 2019 and January 2021, a prospective matched cohort study of patients with distal clavicle fractures Neer type II was conducted in two tertiary trauma centers (Ayatollah Kashani hospital and Al-Zahra, Isfahan, Iran). In the included patients, surgical fixation was needed, and they were fixed with two different instruments: non-locking hook plates and standard non-locking T-plates (Fig. 1). The institutional review board (IRB) of Isfahan university of medical sciences approved the study’s protocol and declared there is no ethical concern (Approval ID: IR.MUI.MED.REC.1399.705). All patients signed a written informed consent statement and voluntarily participated in the study.

Fig. 1
figure 1

Two fixation devices investigated in the study, A T-plate, B hook plate

Surgical technique and postoperative rehabilitation

Patients were operated on by two skilled orthopedic surgeons (M.T and H.R) using either a hook plate or a standard T-plate. Both were titanium 3- or 4-hole 3.5-mm nonlocking plates (Fig. 1). All the surgeries were performed under general anesthesia and in a beach chair position. Through an anterosuperior approach and a ~ 6–8 cm incision, the distal fragment was exposed and reduced under visualization, while the acromioclavicular (AC) joint was preserved. For the hook plate, the hook was inserted under the acromion process. Whenever necessary, the clavicle part was contoured to fit the clavicle to ensure proper fixation. The fixation was completed with 3 screws at both the distal and proximal parts of the plate. For the T-plate, the T-shaped part and shaft plate were slightly flattened to conform to the distal and proximal fragments. Three screws were placed in the T-plate's distal and proximal parts for the final fixation. Fluoroscopy ensured that the screws did not penetrate the acromioclavicular joint. There was no repair of the coracoclavicular ligaments in either group.

Postoperative rehabilitation and management were same for the two groups. Immediately after surgery, patients should wear a sling arm for 2 weeks to protect their shoulder. Ideally, patients should mobilize their shoulder joint as soon as possible, especially if pain free. After two weeks, patients were encouraged to discontinue the sling and increase pendulum exercise up to 90° until 6 weeks. Active shoulder ROM began after 6 weeks post-operation. For hook plate patients, an abduction limit of 90° was prescribed until radiographic proof of healing to prevent implant-related adverse effects. It was not permitted to use the arm vigorously until six months following surgery. Active ROM exercises were begun for the elbow, wrist, and hand after recovering from anesthesia. At our center, supervised physiotherapy was not routine and no patients were sent to physical therapist. For pain management, only Acetaminophen 500 mg PRN was prescribed.

According to recommendations, the implant was removed after union confirmation in the Hook plate at a planned second surgery [12, 23, 24]. The plate removal is the standard procedure in our center. If the patient was satisfied with the hook plate and declined the second surgery, the hook plate remained in place. T-plates were not removed until they became symptomatic.

Outcome measures and data collection

Patients were assessed at 1, 3, and 6 months after discharge. At this time, patients are evaluated by X-ray radiography and physical examination. Standard AP radiography is analyzed for union, and the Constant-Murley score (CMS) is used to assess shoulder function and pain. The definition of the bone union of fractures is the obliteration of the fracture line and bridge of the bony callus [25]. Inadequate radiographic consolidation > 6 months after surgery was defined as non-union. The CMS after six months was the primary outcome measure used to compare the two groups. This measurement includes objective and subjective elements and is scored on a 100-point scale. The scale consists of four domains: pain (15 points), activities of daily living (20 points), range of motion (40 points), and strength (25 points). CMS's minimal clinically important difference (MCID) was determined to be 10.4 [26,27,28]. All the complications assessed and documented during the study follow-up include non-union, fixation loosening, failure, infection, neurovascular damage, periprosthetic fracture, etc.

The physical examinations and functional assessments were conducted by an expert orthopedic resident (J.S, PGY-3) blinded to the study groups. A blind examination of the radiography couldn’t be conducted because of apparent differences in plate shapes between groups in the radiograph. Demographic information and comorbidities of the patient were retrieved.

Participants, sample size, and inclusion criteria

The sample size was estimated using the two-mean comparison formula and based on the data related to the CMS: We considered 0.05 and 0.10 as the type I (α) and II (β) errors, respectively, while σ is the standard deviation of the variable in the population. In addition, µ1 and µ2 are the means of the investigated variables in the two groups. Using the CMS of Erdle et al. study [29] and considering µ1 = 92.2 and µ2 = 88.7 for the two groups and σ = 4.2, the minimum sample size was calculated to be 30 in each group (total sample size of 60 patients).

The inclusion criteria are 1. acute, unstable, isolated unilateral Neer’s type II distal clavicle fracture based on Craig's modification of Neer's classification [30], 2. age between 20 and 50, 3. ASA class I or II, and 4. the size of the clavicle's distal fragment allows the insertion of 3 screws in the distal part of the plate, to allow surgeons to choose either device. The exclusion criteria are 1. undisplaced fracture (Neer’s type I), 2. non-traumatic fractures, 3. concomitant fractures include coracoid, glenoid, acromion, scapula, and proximal humerus or any concomitant shoulder girdle injury, 4. an injury that induced neuropathy and neural complications (hindered clinical examination), 5. prior shoulder pathology and disability, 6. small distal fragment sizes that would limit insertion of three screws, and 7. not intended to participate or be illiterate to complete the follow-up and fill the forms. Patients were enrolled until the sample size was achieved and matched by sex and age (± 5 years).

Statistical analysis

SPSS v.23.0 software (IBM SPSS Inc., USA) was used to analyze the data. Normality was assessed using the Shapiro–Wilk test. Student's t-test, Mann–Whitney test, and Analysis of Variance (ANOVA) were employed to compare continuous variables based on their normality. In addition, the chi-square and Fisher exact tests were used to compare the nominal variables. To compare the group scores at different times, the repeated measures ANOVA test was used. P-value < 0.05 (two-sided) was considered significant.

Results

Sixty consecutive patients with Neer II (A + B) distal clavicle fractures were enrolled in the study, 30 in each of two groups that were matched for age and sex (Fig. 2): 30 in the Hook plate group and 30 in the T-plate group (Fig. 3). Both patient groups were similar in terms of demographics, comorbidities, side of injury, injury to the dominant arm, and smoking status (P > 0.05) (Table 1).

Fig. 2
figure 2

Flow diagram of patients’ enrollment and evaluations

Fig. 3
figure 3

Distal clavicle fracture fixation using A T-plate and B hook plate

Table 1 Demographic characteristics (mean ± SD or n, %)

Table 2 summarizes the study's outcomes. CMS showed similar functional outcomes between the two groups in the three follow-ups (P > 0.05) (Fig. 4a). However, the T-plate group has superior ROM and pain scores at the earliest follow-up than the Hook plate group (CMSpain = 13.0 vs. 12.3, P = 0.03; CMSROM = 35.2 vs. 33.2, P = 0.002) (Fig. 4b) (Fig. 5). Pain and ROM scores were higher but not significantly in the T-plate following future follow-ups (P > 0.05). Both groups showed comparable results in other CMS domains, including activities of daily living and strength (P > 0.05). The union was assessed at 1, 3, and 6 months post-operation, and the mean time to union was 2.5 + 1.4 months for the T-plate group and 2.3 + 1.6 months for the Hook plate group (P = 0.44).

Table 2 Functional scores Constant-Murley score (mean ± SD or n, %)
Fig. 4
figure 4

The comparison of A Constant-Murley scores (CMS) and B CMSpain at different follow-up visits after surgery

Fig. 5
figure 5

Comparison of abduction range of motion in the A T-plate, B and hook plate

Table 3 shows complication rates and reoperation rates across both groups. No intraoperative complications were observed. Regarding postoperative complications, both groups had one fixation failure (Fig. 6). A periprosthetic fracture occurred in one of the Hook Plate patients, who required reoperation (Fig. 7). Thus, 2 revision surgery performed in the hook plate group, while one was performed in the T-plate, and all proceeded with acceptable healing. There were no cases of non-union, surgical site infection, osteolysis, stiffness, or neurovascular damage.

Table 3 Surgical complication and reoperation in T plate and Hook plate
Fig. 6
figure 6

Fixation failure needs revision surgery in the A T-plate and B Hook plate groups

Fig. 7
figure 7

Periprosthetic fracture in hook plate fixation

As a standardized procedure, hook plate removal was performed in all patients (Fig. 8), but in five who declined removal (83.33%). On average, hook plates were removed at 4.5 months (range: 3–6 months) after surgery. In the T-plate group, surgery for hardware removal was advised only in symptomatic patients, and thus no plates were removed by the 6-month follow-up.

Fig. 8
figure 8

X-ray radiograph after plate removal in the Hook plate group

Discussion

The main findings of this study were that using T-plate fixation for the unstable Neer type II distal fracture has comparable good union and functional results compared to hook plating. Although both methods exhibited a low complication rate, using a T-plate is associated with better ROM and pain scores at 1 month. We believe that utilizing a standard non-locking 3.5-mm T-plate device for unstable and displaced distal clavicles is an affordable, novel, and effective method.

A recent meta-analysis of 1261 patients by Malik et al. comparing hook plate and superior plate for treatment of displaced distal clavicle fractures found that the hook plate had a significantly higher overall complication rate (32.7%) than the superior plate (12.7%, OR = 6.3). Hook plate revealed 11.3% acromial osteolysis, 2.8% peri-prosthetic fracture, 1.6% shoulder stiffness, 1.6% impingement, 1.2% infections, and 0.35% rotator cuff tear [31]. Using a superior plate alone caused 11.7% of implants to be removed due to pain or cosmesis and 0.45% infection. However, they showed a similar union rate (~ 97%) and CMS score [31]. Another recent meta-analysis comparing different internal fixation techniques has demonstrated that locking compression plates + coracoclavicular fixation is the most effective and has the least number of complications [4]. Meanwhile, hook plate and other techniques tended to result in lower functional scores and higher complications. Thus, although hook plates provided rigid fixation and high union rates, there are concerns about their complications and lower functional scores [32]. An additional meta-analysis revealed that CMS at 3 and 6 months for the distal clavicle locking plate is superior to clavicle hooks [32]. In agreement with them, we found that all participants had fully healed, but participants who had hook plates experienced more pain and limited ROM of the joint in the first month of follow-up. In the subsequent follow-ups, the two groups were comparable. Complications did not differ between the two groups.

The hook plate is designed to fit the clavicle and acromion anatomically, with the lateral hook nestled beneath the acromion posterior to the AC joint and the body attaching to the superior surface of the clavicle. With the help of the subacromial hook, the body of the plate acts as a depressor, gently pressing the medial fracture fragment down, facilitating bone union and early postoperative mobilization [23, 33, 34]. On the other hand, surgical complications associated with the hook plate were found to be more than plate and screw fixation [2, 4, 31]. Inflammation of the subacromial space, impingement of the rotator cuff, osteolysis of the acromion (27%), and periprosthetic fractures (22%) are all potential consequences of hook placement [1, 16]. The presence of all complications was reported to be even as high as 63% in the previous studies, and most of them were specific to the implant, such as AC joint arthrosis [29]. In this regard, Erdle et al. reported an inferior AC joint-specific score (Taft score) for the hook plate fixation rather than the plate, which could be caused by hook micromotions around the AC joint [29]. The hook plating did not result in osteolysis or acromial fractures in our study. In line with us, Baunach et al. revealed a low number of AC joint arthrosis, subacromial impingement, or rotator cuff tear with hook plate fixation [35]. Early removal of the plate following bone union may be crucial to preventing complications [35].

The only study that compared T-plate and hook plate directly by Tan et al. [11], showed that the T-plate group demonstrated greater improvements in activities of daily living, pain, and ROM, resulting in a higher rate of excellent and good results (UCLA score > 29) than the hook plate group (P = 0.001). When the hook plates were taken off, shoulder function improved greatly due to pain relief, and UCLA scores were equal to those of the T-plate group [11]. They did not nevertheless, their study had a retrospective design and had a low sample size which could affect the results. The material properties of locking plates also make them more expensive than non-locking ones, and developing countries have less access to them [36, 37]. However, we used a standard non-locking T-plate due to lower cost and accessibility in our developing country. Similar to our study, pain at the beginning limited ROM and function in the hook plate group, but at the last follow-up a similar score was reached as in the T-plate group. The pain can impair shoulder function, especially in the case of > 90° abduction.

The Tan et al. [11] study did not report any complications for the T-plate group. Additionally, we did not observe any complications in our study except for a fixation failure in the T-plate group, which was the same as in the hook plate group. In theory, T-plates are low-profile metals that do not rigidly fix fractures as hook plates do with their hooks. This could increase the risk of fixation failure and loosen in old-aged patients with compromised bone density. Future studies should test this hypothesis. In addition, T-plate fixation is impossible in patients with small distal fragments for insertion of 3 screws. Other complications seem to be similar to those observed in this study.

This study utilized a 3.5-mm standard non-locking T-plate that is typically used for distal radial fractures, but it provided fixation at this site by placing multiple screws in the small distal fragment. Using multiple screws and a higher angle of fixation improves fracture fixation, resulting in better grip, increased resistance to fracture extraction, and a more effective fixation [11, 38]. The T-plate does not enter the subacromial space and thus does not induce rotator cuff damage or impingement [17,18,19, 22, 39]. This technique induced lower cost than locking one [36, 37], and having no prior plan for plate removal surgery in the absence of symptoms made it more affordable than hook plate fixation [40]. It is crucial in developing countries such as ours that have limited access to expensive implants. According to a study by Fox et al. regarding the cost-effectiveness of several fixation methods for Neer 2 distal clavicle fractures, the double suture button technique is the most cost-effective method due to its low revision and complication rates [40]. A hook plate costs significantly more than suture buttons and locking plates from a healthcare perspective ($5,360 vs. $3,713 and $4,007 respectively) [40]. It was found that locking plates and suture buttons produced similar clinical results. This cost difference between hook plates and the two superior strategies is the result of the loss of productivity caused by hook plate removal [40].

This study faces serious limitations. First, the allocation to two groups was not random, making it susceptible to selection bias. Secondly, the follow-up period was limited to 6 months, and short follow-ups make it impossible to determine the long-term results of the two groups. However, the non-union in the clavicle is defined by 6 months of lack of healing [41], and all the participants showed complete union during the study period. Finally, the surgery was not preceded by MRI imaging, nor did we detect soft tissue and ligament damage during the procedure. Therefore, we cannot provide the type of fracture (IIA or IIB) in the participants. The strength of this study is the prospective follow-up without dropouts and the sufficient matched sample size.

Conclusion

Based on the results of our study, both surgical approaches were associated with complete healing and good functional scores. However, in the hook plate group ROM and pain scores were lower at 1-month. The patients undergoing T-plate fixation did not need hardware removal within the first six postoperative months. Thus, it may have potential advantages to the hook plate that should be addressed in future investigations. Standard non-locking T-plates are a viable alternative to hook plates with low cost and promising outcomes for treating displaced distal clavicle fractures.

Availability of data and materials

Not applicable.

References

  1. Asadollahi S, Bucknill A. Hook plate fixation for acute unstable distal clavicle fracture: a systematic review and meta-analysis. J Orthop Trauma. 2019;33(8):417–22.

    Article  Google Scholar 

  2. Boonard M, Sumanont S, Arirachakaran A, Sikarinkul E, Ratanapongpean P, Kanchanatawan W, et al. Fixation method for treatment of unstable distal clavicle fracture: systematic review and network meta-analysis. Eur J Orthop Surg Traumatol. 2018;28(6):1065–78.

    Article  Google Scholar 

  3. Kirsch JM, Blum L, Hake ME. Distal clavicle fractures: open reduction and internal fixation with a hook plate. J Orthop Trauma. 2018;32(Suppl 1):S2-s3.

    Article  Google Scholar 

  4. Xu Y, Guo X, Peng H, Dai H, Huang Z, Zhao J. Different internal fixation methods for unstable distal clavicle fractures in adults: a systematic review and network meta-analysis. J Orthop Surg Res. 2022;17(1):43.

    Article  Google Scholar 

  5. Panagopoulos A, Solou K, Tatani I, Triantafyllopoulos IK, Lakoumentas J, Kouzelis A, et al. What is the optimal surgical treatment for Neer type IIB (IIC) distal clavicle fractures? A systematic review and meta-analysis. J Orthop Surg Res. 2022;17(1):215.

    Article  Google Scholar 

  6. Edwards DJ, Kavanagh TG, Flannery MC. Fractures of the distal clavicle: a case for fixation. Injury. 1992;23(1):44–6.

    Article  CAS  Google Scholar 

  7. Uittenbogaard SJ, van Es LJM, den Haan C, van Deurzen DFP, van den Bekerom MPJ. Outcomes, union rate, and complications after operative and nonoperative treatments of Neer type II distal clavicle fractures: a systematic review and meta-analysis of 2284 patients. Am J Sports Med. 2021. https://doi.org/10.1177/03635465211053336.

    Article  PubMed  Google Scholar 

  8. Yoo JH, Chang JD, Seo YJ, Shin JH. Stable fixation of distal clavicle fracture with comminuted superior cortex using oblique T-plate and cerclage wiring. Injury. 2009;40(4):455–7.

    Article  Google Scholar 

  9. Babhulkar A, Pawaskar A. Acromioclavicular joint dislocations. Curr Rev Musculoskelet Med. 2014;7(1):33–9.

    Article  Google Scholar 

  10. Neer CS 2nd. Fractures of the distal third of the clavicle. Clin Orthop Relat Res. 1968;58:43–50.

    PubMed  Google Scholar 

  11. Tan HL, Zhao JK, Qian C, Shi Y, Zhou Q. Clinical results of treatment using a clavicular hook plate versus a T-plate in neer type II distal clavicle fractures. Orthopedics. 2012;35(8):e1191–7.

    Article  Google Scholar 

  12. Kashii M, Inui H, Yamamoto K. Surgical treatment of distal clavicle fractures using the clavicular hook plate. Clin Orthop Relat Res. 2006;447:158–64.

    Article  Google Scholar 

  13. Tambe AD, Motkur P, Qamar A, Drew S, Turner SM. Fractures of the distal third of the clavicle treated by hook plating. Int Orthop. 2006;30(1):7–10.

    Article  CAS  Google Scholar 

  14. Xie J, Xu D, Zheng X, Zhou M, Ouyang W, Zhang T, Lu L. Kirschner wire temporary intramedullary fixation combined with a locking anatomical plate versus a reconstruction plate in the treatment of comminuted clavicular fractures: a retrospective study. Biomed Res Int. 2018. https://doi.org/10.1155/2018/5017162.

    Article  PubMed  PubMed Central  Google Scholar 

  15. Chiang CL, Yang SW, Tsai MY, Kuen-Huang CC. Acromion osteolysis and fracture after hook plate fixation for acromioclavicular joint dislocation: a case report. J Shoulder Elbow Surg. 2010;19(4):e13–5.

    Article  Google Scholar 

  16. Stegeman SA, Nacak H, Huvenaars KH, Stijnen T, Krijnen P, Schipper IB. Surgical treatment of Neer type-II fractures of the distal clavicle: a meta-analysis. Acta Orthop. 2013;84(2):184–90.

    Article  Google Scholar 

  17. Wu K, Su X, Roche SJL, Held MFG, Yang H, Dunn RN, et al. Relationship between the lateral acromion angle and postoperative persistent pain of distal clavicle fracture treated with clavicle hook plate. J Orthop Surg Res. 2020;15(1):217.

    Article  Google Scholar 

  18. Lin H-Y, Wong P-K, Ho W-P, Chuang T-Y, Liao Y-S, Wong C-C. Clavicular hook plate may induce subacromial shoulder impingement and rotator cuff lesion-dynamic sonographic evaluation. J Orthop Surg Res. 2014;9(1):6.

    Article  Google Scholar 

  19. Kalamaras M, Cutbush K, Robinson M. A method for internal fixation of unstable distal clavicle fractures: early observations using a new technique. J Shoulder Elbow Surg. 2008;17(1):60–2.

    Article  Google Scholar 

  20. Klein SM, Badman BL, Keating CJ, Devinney DS, Frankle MA, Mighell MA. Results of surgical treatment for unstable distal clavicular fractures. J Shoulder Elbow Surg. 2010;19(7):1049–55.

    Article  Google Scholar 

  21. Yu C, Sun YH, Zhao CQ, Shi DW, Wang Y. Treatment of distal clavicle fracture with distal radius volar locking compression plate. Chin J Traumatol. 2009;12(5):299–301.

    PubMed  Google Scholar 

  22. Herrmann S, Schmidmaier G, Greiner S. Stabilisation of vertical unstable distal clavicular fractures (Neer 2b) using locking T-plates and suture anchors. Injury. 2009;40(3):236–9.

    Article  CAS  Google Scholar 

  23. Haidar SG, Krishnan KM, Deshmukh SC. Hook plate fixation for type II fractures of the lateral end of the clavicle. J Shoulder Elbow Surg. 2006;15(4):419–23.

    Article  Google Scholar 

  24. Muramatsu K, Shigetomi M, Matsunaga T, Murata Y, Taguchi T. Use of the AO hook-plate for treatment of unstable fractures of the distal clavicle. Arch Orthop Trauma Surg. 2007;127(3):191–4.

    Article  CAS  Google Scholar 

  25. Corrales LA, Morshed S, Bhandari M, Miclau T 3rd. Variability in the assessment of fracture-healing in orthopaedic trauma studies. J Bone Joint Surg Am. 2008;90(9):1862–8.

    Article  Google Scholar 

  26. Constant CR, Murley AH. A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res. 1987;214:160–4.

    Article  Google Scholar 

  27. Kukkonen J, Kauko T, Vahlberg T, Joukainen A, Aärimaa V. Investigating minimal clinically important difference for Constant score in patients undergoing rotator cuff surgery. J Shoulder Elbow Surg. 2013;22(12):1650–5.

    Article  Google Scholar 

  28. Hajivandi S, Dachek A, Salimi A, Mamaghani HJ, Mirghaderi SP, Dehghani J, et al. Comparison of the separate and combined effects of physiotherapy treatment and corticosteroid injection on the range of motion and pain in nontraumatic rotator cuff tear: a randomized controlled trial. Adv Orthop. 2021;2021:6789453.

    Article  Google Scholar 

  29. Erdle B, Izadpanah K, Jaeger M, Jensen P, Konstantinidis L, Zwingmann J, et al. Comparative analysis of locking plate versus hook plate osteosynthesis of Neer type IIB lateral clavicle fractures. Arch Orthop Trauma Surg. 2017;137(5):651–62.

    Article  Google Scholar 

  30. Craig E. Fractures of the clavicle. In: Rockwood CA, Matsen FA, editors. The shoulder. Philadelphia: WB Saunders; 1990.

    Google Scholar 

  31. Malik SS, Tahir M, Remtulla M, Malik S, Jordan RW. A systematic review and meta-analysis comparing the use of hook plates and superior plates in the treatment of displaced distal clavicle fractures. Arch Orthop Trauma Surg. 2022. https://doi.org/10.1007/s00402-021-04287-z.

    Article  PubMed  Google Scholar 

  32. Li L, Li T-y, Jiang P, Lin G, Wu H, Han X, Yu X. Clavicle hook plate versus distal clavicle locking plate for Neer type II distal clavicle fractures. J Orthop Surg Res. 2019;14(1):472.

    Article  Google Scholar 

  33. Flinkkilä T, Ristiniemi J, Hyvönen P, Hämäläinen M. Surgical treatment of unstable fractures of the distal clavicle: a comparative study of Kirschner wire and clavicular hook plate fixation. Acta Orthop Scand. 2002;73(1):50–3.

    Article  Google Scholar 

  34. Chen C-Y, Yang S-W, Lin K-Y, Lin K-C, Tarng Y-W, Renn J-H, et al. Comparison of single coracoclavicular suture fixation and hook plate for the treatment of acute unstable distal clavicle fractures. J Orthop Surg Res. 2014;9(1):42.

    Article  Google Scholar 

  35. Baunach D, Eid K, Ricks M, Borbas P. Long-term clinical and radiological results after hook plate osteosynthesis of lateral clavicle fractures. J Orthop Trauma. 2021;35(7):378–83.

    Article  Google Scholar 

  36. Primeau C, Marsh J, Birmingham T, Giffin J. Cost-effectiveness of a locking versus non-locking reconstruction plate in medial opening wedge high tibial osteotomy: the importance of costing perspective. Osteoarthr Cartil. 2018;26:S280–1.

    Article  Google Scholar 

  37. Zhou K-H, Chen N. Locking versus non-locking neutralization plates with limited excision and internal fixation for treatment of extra-articular type a distal tibial fractures. Open Orthop J. 2017;11:57–63.

    Article  Google Scholar 

  38. Frima H, Houwert RM, Sommer C. Displaced medial clavicle fractures: operative treatment with locking compression plate fixation. Eur J Trauma Emerg Surg. 2020;46(1):207–13.

    Article  Google Scholar 

  39. Kang HJ, Kim HS, Kim SJ, Yoo JH. Osteosynthesis of symptomatic nonunions of type II fractures of the distal clavicle using modified locking T-plate and bone grafting. J Trauma Acute Care Surg. 2012;72(2):E14–9.

    Article  Google Scholar 

  40. Fox HM, Ramsey DC, Thompson AR, Hoekstra CJ, Mirarchi AJ, Nazir OF. Neer type-II distal clavicle fractures: a cost-effectiveness analysis of fixation techniques. J Bone Joint Surg Am. 2020;102(3):254–61.

    Article  Google Scholar 

  41. Stufkens SA, Kloen P. Treatment of midshaft clavicular delayed and non-unions with anteroinferior locking compression plating. Arch Orthop Trauma Surg. 2010;130(2):159–64.

    Article  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

There is no funding source for authors to declare.

Author information

Authors and Affiliations

Authors

Contributions

MT and HR contributed to the study conception and design. Material preparation, draft writing, and data collection were performed by AF, and JS and SPM analyzed data, revised the manuscript, and supervised the study. All authors commented on previous versions of the manuscript and revised them. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Seyed Peyman Mirghaderi.

Ethics declarations

Ethics approval and consent to participate

All procedures performed in studies involving human participants were under the ethical standards of the national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. (Approval ID: IR.MUI.MED.REC.1399.705). An informed consent signed by all the study participants.

Consent for publication

Patient consent was obtained regarding the publication of data and photographs.

Competing interests

The authors have no relevant financial or non-financial interests to disclose.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Teimouri, M., Ravanbod, H., Farrokhzad, A. et al. Comparison of hook plate versus T-plate in the treatment of Neer type II distal clavicle fractures: a prospective matched comparative cohort study. J Orthop Surg Res 17, 369 (2022). https://doi.org/10.1186/s13018-022-03261-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13018-022-03261-8

Keywords