Correction to: The feasibility of short-segment Schanz screw implanted in an oblique downward direction for the treatment of lumbar 1 burst fracture: a finite element analysis
Journal of Orthopaedic Surgery and Research volume 15, Article number: 606 (2020)
Correction to: J Orthop Surg Res (2020) 15:537
https://doi.org/10.1186/s13018-020-02024-7
Following publication of the original article [1], due to a typesetting error, the figure legends for Figs. 1, 3, 4, 6 and 7 were wrongly published. The correct figure legends are given below.
a After the reduction of thoracolumbar burst fractures, the wedge-shaped bone defect area in the sagittal position was wide in the front and narrow in the back. b AUVH accounts for 15% of the leading edge of the vertebral body, ADH accounts for 50% of the leading edge of the vertebral body, and ALVH accounts for 35% of the leading edge of the vertebral body. AUVH, anterior upper vertebral body height above the bony defect; ADH, anterior bony defect height; ALVH, anterior lower vertebral body height below the bony defect
The stress nephogram of the Schanz pedicle screw for the L1 severe fractures after T12 and L2 pedicle screw fixation during anterior flexion. Red is the maximum stress. The maximum stress occurred at the interface of the proximal pedicle and cortical bone, and the stress of the upper screw is greater than that of the lower screw. A1–A6 0°, B1–B6 5°, C1–C6 10°, and D1–D6 15°. There are 6 models in each group
The stress nephogram of the Schanz pedicle screw for the L1 severe fractures after T12 and L2 pedicle screw fixation during posterior extension. Red is the maximum stress. The maximum stress occurred at the interface of the proximal pedicle and cortical bone, and the stress of the upper screw is greater than that of the lower screw. A1–A6 0°, B1–B6 5°, C1–C6 10°, and D1–D6 15°. There are 6 models in each group
Axial (Z-axis) displacement nephogram of the micro-motion of the vertebral defect area of Schanz pedicle screw for L1 severe fracture during anterior flexion. Red is the maximum displacement upward, and blue is the maximum displacement downward. A1–A6 0°, B1–B6 5°, C1–C6 10°, and D1–D6 15°. There are 6 models in each group
Axial (Z-axis) displacement nephogram of the micro-motion of vertebral defect area of Schanz pedicle screw for L1 severe fracture during posterior extension. Red is the maximum displacement upward, and blue is the maximum displacement downward. A1–A6 0°, B1–B6 5°, C1–C6 10°, and D1–D6 15°. There are 6 models in each group
The authors would also like to correct the citation form page 10.
Incorrect: [1, 19]
Correct: [10]
The original article has been corrected.
Reference
Liu J, et al. The feasibility of short-segment Schanz screw implanted in an oblique downward direction for the treatment of lumbar 1 burst fracture: a finite element analysis. J Orthop Surg Res. 2020;15:537 https://doi.org/10.1186/s13018-020-02024-7.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
About this article
Cite this article
Liu, J., Yang, S., Zhou, F. et al. Correction to: The feasibility of short-segment Schanz screw implanted in an oblique downward direction for the treatment of lumbar 1 burst fracture: a finite element analysis. J Orthop Surg Res 15, 606 (2020). https://doi.org/10.1186/s13018-020-02134-2
Published:
DOI: https://doi.org/10.1186/s13018-020-02134-2