Skip to main content

Minimally invasive unilateral pedicle screws and a translaminar facet screw fixation and interbody fusion for treatment of single-segment lower lumbar vertebral disease: surgical technique and preliminary clinical results

Abstract

Background

Conventional open transforaminal lumbar interbody fusion (TLIF) using unilateral pedicle screws and a translaminar facet screw has been performed for many years with good results. The outcomes of minimally invasive TLIF (MIS TLIF) are similar to the good outcomes of open TLIF, with the additional benefits of reducing iatrogenic injury, shortening hospital stays, and reducing the recovery duration. Instead of using small cuts on both sides, we performed MIS TLIF through a single cut using unilateral pedicle screws and a translaminar facet screw. The operative feasibility, efficacy safety, and benefits of single-level MIS TLIF of such techniques require further clarification.

Methods

A total of 60 patients with various single-segment lower lumbar vertebral diseases were treated in our department from January 2010 to March 2013. All the patients were initially performed single-level MIS TLIF using a hybrid construction of unilateral pedicle screws and a translaminar facet screw. Patient demographics and operative data were collected. The clinical outcomes were assessed before surgery and 3, 6, 12, and 24 months after surgery using the visual analog scale (VAS) for back and leg pain and the Oswestry Disability Index (ODI). Radiologic assessment of the lumbar spine with static and dynamic plain radiographs was performed 3, 6, 12, and 24 months after surgery. The fusion rates were assessed by an independent radiologist 2 years after surgery according to the Bridwell interbody fusion grading system.

Results

No patients experienced significant postoperative complications. Excepting two cases, 58 cases were followed up for 24–38 months, averaged 29.9 ± 4.1 months. The patients’ average age was 46.6 ± 11.5 years, operative time 109.7 ± 17.8 min, intraoperative blood loss 67.3 ± 29.7 ml, length of incision 29.0 ± 3.2 mm, fluoroscopy time 31.1 ± 7.2 s, time to ambulation 20.3 ± 7.0 h, length of hospital stay 5.1 ± 1.1 days, and length of the translaminar facet screw 51.7 ± 3.4 mm. Screw position results: type I, 54 cases with 54 segments; type II, four cases with four segments. There were two (3.4%) translaminar facet screw failures, which were intraoperatively converted to a bilateral pedicle screw fixation procedure and excluded from the research. The postoperative images showed good positioning of the hybrid internal fixation, and all of the translaminar facet screws penetrated the facet joint. Two (3.6%) translaminar facet screws penetrated the lateral lamina and two (3.6%) translaminar facet screws penetrated the medial lamina without any serious neural complications. During the follow-up, there was no screw loosening or pedicle fracture observed. The VAS and ODI scores were significantly improved compared with the preoperative scores (P < 0.05), and the symptoms disappeared gradually. Fifty-one patients (87.9%) achieved grade I fusion radiographically at the final follow-up.

Conclusions

MIS TLIF using a hybrid construction of unilateral pedicle screws and a translaminar facet screw is safe and effective in the treatment of single-segment lower lumbar vertebral disease, and it can be used as an optimal choice for fixation and fusion of some single-segment lower lumbar vertebral diseases.

Background

Bilateral pedicle screw fixation combined with interbody fusion has been recognized as the “gold standard” treatment for the lumbar vertebral disease, which has a variety of advantages, such as great fixation intensity, excellent stability, and high fusion rate [1,2,3,4,5,6,7,8]. However, with its extensive use in the clinic, many disadvantages of the treatment have been reported, which includes long skin incision, considerable stress of internal fixation by strong fixation, stress shielding in the fixed segment, and the potential accelerated degeneration of adjacent segments [9,10,11]. Thus, surgeons have searched several modified fixation techniques, such as unilateral pedicle screw (UPS), and UPS plus contralateral translaminar facet screw (UPSFS) which has come into use, and acquired good clinical outcome and satisfied fusion rate [12,13,14].

Unilateral pedicle screw fixation combined with interbody fusion has been extensively used in the clinic, which has gotten a primarily good clinic result. Significant reductions in operation time, duration of hospitalization, and costs have been cited as the benefits of unilateral pedicle screw fixation (PSF) [12]. And some studies even showed that the unilateral PSF has equivalent fusion rates compared with the bilateral PSF [15]. However, biomedical studies indicated that this method failed to control lateral bending and resist torsional forces, potentially resulting in stress concentration and increasing the risk of internal fixation failure [16,17,18,19]. Translaminar facet screw fixation is another important method for lumbar fixation. Many relevant studies confirmed its availability in the clinic application [20, 21]. The translaminar facet screw was first introduced by King in 1948, and this technique involved the insertion of a short screw across the facet joint [22]. Translaminar facet screw fixation (TFSF) was initially described as a form of posterior instrumented fusion for lumbosacral degenerative disease by Magerl in the 1980s [23, 24]. The screw is a long screw that enters through the base of the spinous process on one side, fixes the contralateral facet joint after traversing the lamina, and ends at the base of the transverse process [23]. This procedure has been shown to be a successful technique that offers ease of procedure, smaller incisions, few complications, and reduced implant costs [25,26,27,28,29].

In addition to interbody fusion, TFSF offers a strong alternative to PSF with the same indications. However, the traditional use of TFSF also requires extensive paraspinal muscle retraction for insertion with consequent increased infection rates and muscle injury, and it carries a risk of neural and vascular damage as a result of improperly placed screws [7, 26, 30]. Researchers have attempted to achieve satisfactory lumbar fusion using minimally invasive (MIS) techniques that reduce injury and implant costs.

As a means of providing suitable spine stiffness with minimal injury and implant load, a hybrid construction of unilateral pedicle screws with a contralateral translaminar facet screw has been studied more frequently [14, 18, 31,32,33,34]. Biomechanical studies have certified the comparable strengths of bilateral PSF and unilateral pedicle screws and translaminar facet screw combination [18, 31, 33, 34]. Clinical outcomes have shown that open transforaminal lumbar interbody fusion (TLIF) using unilateral pedicle screws and a translaminar facet screw offers good results [14]. However, few studies on MIS TLIF using unilateral pedicle screws and a translaminar facet screw have been reported [32]. Hence, the feasibility, clinical outcomes, and fusion rates of unilateral pedicle screws combined with a translaminar facet screw in single-segment lower lumbar vertebral disease were investigated in this study.

Methods

Ethics statement

This study has been approved by the Ethics Committee of the Chinese PLA General Hospital, and the approval number is K2010-011-02. Written informed consent was obtained from each patient prior to the study.

Inclusion and exclusion criteria

Inclusion criteria were patients with (I) single-segment lower lumbar vertebral disease; (II) chronic low back pain with or without neurological symptoms of lower extremities; and (III) inefficacy after strict conservative treatment for more than 6 months. Imaging findings showed serious single segmental degeneration disease, unilateral intervertebral disc herniation, or lumbar instability, which are consistent with the symptoms and signs. Exclusion criteria were (I) lumbar degenerative spondylolisthesis (II degree or higher); (II) lumbar spondylolysis; (III) serious three-dimensional deformity of lumbar vertebrae; (IV) obvious osteoporosis of lumbar vertebrae; and (V) patients with multi-segment lumbar degenerative disease, revision surgery, spinal tumor, acute spinal trauma, and spinal infections.

General information

This study included 60 patients (34 male, 26 female) aged 22 to 67 years (mean, 46.6 years). All the patients have a history of lumbar degenerative disease and had been treated conservatively for at least 6 months without success. The patients were evaluated with a routine lumbar X-ray, computed tomography (CT), and magnetic resonance imaging at admission, and the signs and symptoms of the patients were consistent with the imaging findings. Fifty-eight patients underwent single-level MIS TLIF by the same experienced surgeon using a hybrid construct fixation with unilateral pedicle screws combined with contralateral translaminar facet screw. It was the first lumbar surgery at that level for all of the patients, and the indication for surgery was chronic low back pain, intermittent claudication, and unilateral radicular complaints. The translaminar facet screw length and the thickness and oblique angle of the laminar were measured according to the preoperative lumbar X-ray and CT. The hybrid construct fixation was used at the L4–L5 level in 23 patients and at the L5–S1 level in 35 patients. Thirty-five patients underwent translaminar fixation on the left side, and 23 patients underwent fixation on the right side. The minimum follow-up was 24 months (range 24 to 38 months).

Surgical technique

The MIS TLIF procedure was performed on the side that appeared symptomatic. Under general anesthesia, the patient was placed in a prone position on a radiolucent operative frame. The surgical procedure consisted of the following steps:

  1. 1.

    Incision and placement of tubular retractor: With the help of a C arm, a longitudinal incision was made in the skin 3–4 cm lateral to the midline on the symptomatic side. The incision was generally 2.5–3 cm long, which was sufficient for the placement of the tubular retractor (METRx system, Medtronic Sofamor Danek, USA).

  2. 2.

    Discectomy, decompression, and fusion: After blunt dissection of the longissimus and multifidus muscles, progressive dilation of the dissected plane was completed. The tubular retractor was then docked over the facet joint at the level of the surgery. After clearance of the reliquus soft tissues under direct vision, the peripheral lamina and the facet joint were exposed. Canals for the pedicle screws were prepared with the help of a C arm. A complete facetectomy was then performed, and the ligamentum flavum was resected. After the traversing and exiting nerve roots were identified, a rigorous discectomy was conducted and the cartilage end plates were removed using curettement. A sufficient local autologous bone graft taken from the removed facet was used to fill the disc space. A single appropriately sized PEEK cage (Concorde, DePuy Spine, USA) packed with locally harvested autologous cancellous bone was inserted obliquely across the disc space. When sufficient decompression was completed, two pedicle screws and a rod (Exp, Depuy Spine, USA) were implanted before the final tightening.

  3. 3.

    Translaminar facet screw fixation: The lateral and laminar angles of the translaminar facet screw to be fused were measured preoperatively using X-ray and CT or MR imaging. After the MIS TLIF and unilateral PSF procedure, the tube was adjusted to provide an oblique view of the base of the superior spinous process. This facilitated the entry of a 2.2-mm-diameter drill. Considering the preoperatively determined lateral and laminar angles, the drill was inserted through the same incision under radiological guidance. During the drill’s insertion, care was taken to ensure that it remained within the cortical confines of the lamina. After drilling, a 4.5-mm-diameter cortical screw (AO Spine, USA) of suitable length (usually 45–58 mm) was inserted for fixation, traversing through the lamina and facet joints and terminating at the base of the transverse process. Accurate placement of the screw was confirmed using the C arm or intraoperative CT prior to wound closure. A representative case is presented in Fig. 1.

    Fig. 1
    figure 1

    The preoperative MRI (a, b) showed a herniated disc. Accurate placement of the translaminar facet screw (c, d) was accomplished using the C arm intraoperatively. A small skin incision (e) was showed. Anteroposterior (f) and lateral (g) views after MIS TLIF showed good position of the hybrid internal fixation. CT scans (hj) at 2 years after surgery demonstrated solid interbody fusion, and the translaminar facet screw entered through the base of spinous process on one side, fixed the contralateral facet joint after traversing the laminar, and ended at the base of the transverse process

Postoperative treatment

Patients received routine postoperative management, including infection prevention, and low-dose hormones and correction of dehydration and gastric mucosal protective measures and bed rest. After waking from anesthesia, the patients were encouraged to actively dorsiflex the ankle and perform straight leg raises with both lower legs. All the patients did not need to have a drainage tube. Patients wore waist support and were encouraged out-of-bed activity 3 to 5 days postoperatively. With the help of a waist girdle, progressive back and abdominal muscle exercises were initiated at the sixth week postoperatively.

Evaluation method

The data recorded for analysis were age, gender, operative time, intraoperative blood loss, length of incision, X-ray exposure time, length of the translaminar facet screw, time to ambulation, length of hospital stay, complications, and the clinical and radiographic results after surgery. After surgery or discharge from the hospital, the patients received regular, close follow-up (at 3 days, 3 months, 6 months, and 1 year postoperation and annually thereafter). Clinical and radiological evaluations were conducted at every follow-up visit. All of the data were collected prospectively after a minimum of 2 years of follow-up. The patients were evaluated using the visual analog scale (VAS) for leg and back pain and the Oswestry Disability Index (ODI), version 2.0. The radiological evaluation included anteroposterior, lateral, oblique, and flexion-extension plain radiography, CT scans, and MRI. Translaminar facet screw and interbody fusion were assessed by imaging. Translaminar facet screw position was classified into three types: type I, the translaminar facet screw is located in the lamina; type II, the translaminar facet screw penetrates the lamina partially; and type III, the translaminar facet screw penetrated the lamina completely [35]. Fusion rates based on the Bridwell interbody fusion grading system were assessed using static and dynamic plain radiography 2 years postoperatively [36]. The Bridwell interbody fusion grading system is provided in Table 1.

Table 1 Bridwell interbody fusion grading system

Statistical analysis

SPSS 17.0 (SPSS, Chicago, IL) was used for the statistical analyses. Normally distributed continuous variables are shown as the mean ± SD. Analysis of variance (ANOVA) was performed for the VAS and ODI scores. A P value less than 0.05 was considered statistically significant.

Results

General information

A total of 58 patients were followed up in the study. The mean age of the patients was 46.6 ± 11.5 years (range 22–67 years), and the mean follow-up period was 29.9 ± 4.1 months (range 24–38 months).

Operative data

The mean operative time was 109.7 ± 17.8 min (range 73–157 min); the mean intraoperative blood loss was 67.3 ± 29.7 ml (range 26–157 ml); the mean length of incision was 29.0 ± 3.2 mm (range 24–37 mm); the mean fluoroscopy time was 31.1 ± 7.2 s (range 19–53 s); the mean ambulation time was 20.3 ± 7.0 h (range 8–42 h); the mean length of hospital stay was 5.1 ± 1.1 days (range 3–8 days); and the mean translaminar facet screw length was 51.7 ± 3.4 mm (range 45–58 mm). Translaminar facet screw positions were assessed as follows: type I, 54 cases with 54 segments, and type II, four cases with four segments.

Follow-up

During the follow-up, there were significant improvements in both the VAS score for back and leg pain and the ODI scores at all time points compared with the preoperation scores (P < 0.05). The symptoms disappeared gradually. The VAS and ODI scores are listed in Table 2. Fifty-one patients (87.9%) achieved grade I fusion radiographically at the 2-year follow-up. There were no cases of grade III or IV fusions.

Table 2 Results of VAS and ODI score

Complications

Two (3.4%) cases of small dural tears during decompression were not repaired, and these two patients were kept on bed rest for 10 days with no subsequent postoperative cerebrospinal fluid leakage. One (1.7%) case of fat liquefaction experienced primary healing after physical therapy and changing of the dressings. There were two translaminar facet screw failures that were intraoperatively converted to pedicle screws (bilateral PSF). The postoperative images showed good positioning of the hybrid internal fixation, and all of the translaminar facet screws penetrated the facet joint. Two (3.6%) translaminar facet screws penetrated the lateral lamina, and two (3.6%) translaminar facet screws penetrated the medial lamina with no serious neural complications. One (1.7%) patient who required temporary new radiculopathy because of translaminar facet screw malpositioning experienced a full recovery within 2 weeks after subsequent corrective surgery.

Discussion

In this study, a tubular retractor was adopted to expose the lamina and articular process. Facetectomy, discectomy, intervertebral clearance, intervertebral bone grafting, and cage placement were then performed. Unilateral pedicle screws combined with a contralateral translaminar facet screw fixation based on preoperative measured data were conducted. Previous studies indicated that translaminar facet screw fixation is a simple, safe, and satisfactory method [29, 37]. Our results revealed that the direction of the drill in the lamina and screw placement were the most important step in this operation. Postoperatively, imaging data indicated that the position of the translaminar facet screws was good (type I, 53 cases with 54 segments; type II, three cases with four segments). In this operation, only a 3–4-cm longitudinal incision was made in the skin lateral to the midline on the symptomatic side, while the muscles, facet joint, and laminar on the contralateral side remained intact, which is important to reduce surgical trauma and blood loss and shorten operative time [38]. The mean operative time was 109.7 ± 17.8 min (range 73–157 min); the mean intraoperative blood loss was 67.3 ± 29.7 ml (range 26–157 ml); the mean length of incision was 29.0 ± 3.2 mm (range 24–37 mm); the mean fluoroscopy time was 31.1 ± 7.2 s (range 19–53 s); the mean ambulation time was 20.3 ± 7.0 h (range 8–42 h); the mean length of hospital stay was 5.1 ± 1.1 days (range 3–8 days); and the mean translaminar facet screw length was 51.7 ± 3.4 mm (range 45–58 mm). The low intraoperative blood loss, small skin incision, reduced trauma, and short operative time all contributed to moderate pain and rapid recovery postoperatively. In addition, all patients wore waist support and were encouraged out-of-bed activity 3 to 5 days postoperatively. With the help of a waist girdle, progressive back and abdominal muscle exercises were initiated at the sixth week postoperatively and no fixation loosening and breakage were observed during the follow-up. Fifty-one patients (87.9%) achieved grade I fusion radiographically at the 2-year follow-up. There were no cases of grade III or IV fusions. Sethi et al. also achieved bony fusion among 19 patients with low lumbar lesions using unilateral pedicle screws and a translaminar screw fixation technique [14]. The results of Sethi and our study both indicated that unilateral pedicle screw fixation combined with contralateral translaminar facet screw fixation and interbody fusion technique can obtain satisfactory clinical results. Moreover, significant differences in VAS and ODI scores were observed between the final follow-up and preoperation. The leg and back pain, lumbar function, and activities of daily living were obviously improved. Compared with the conventional internal fixation technique [14, 39], our study indicated that unilateral pedicle screw fixation combined with contralateral translaminar facet screw fixation and interbody fusion can obtain the same satisfactory clinical results.

However, several other surgical techniques are available to obtain single segmental lumbar interbody fusion at present. PSF is frequently used to provide temporary spinal stability after spinal surgery until a fusion mass forms [12, 15]. Although it offers the advantage of solid stability, bilateral PSF use is associated with higher implant costs and an increased incidence of neurologic complications [40, 41]. Furthermore, it requires extensive paraspinal muscle retraction for the insertion of the screws, which results in increased rates of infection and muscle injury, and improperly placed screws can lead to neural and vascular damage [7, 26, 30]. With the aim of reducing operative time and implant costs, some researchers have attempted to use unilateral PSF for lumbar spinal fusion [12]. However, unilateral PSF has not been recommended for long fusions despite studies that show comparable fusion rates for unilateral and bilateral PSF [15, 18]. The authors of several biomechanical investigations have demonstrated that unilateral PSF decreases spinal stiffness [18, 19].

Many researchers have shown that translaminar facet screw insertion provides a comparable rate of fusion and satisfactory clinical outcomes provided that the indications are correctly applied [29, 37]. The current study supports the use of TFSF for short-segment fusion in the lumbar spine as a successful technique with the benefits of a relatively simple procedure, smaller incisions, few complications, and reduced implant costs [25,26,27,28,29]. Currently, the hybrid construct of unilateral pedicle screws combined with a contralateral translaminar facet screw is being increasingly investigated because it provides suitable spine stiffness with minimal injury and implant loads [14, 18, 31,32,33,34]. Several biomechanical studies have shown that the hybrid construction provides a strength similar to that of bilateral PSF [18, 31, 33, 34]. Sethi and Lee documented the good clinical outcomes of open TLIF using unilateral pedicle screws and a translaminar facet screw (similar to the system we used in our study), and they suggested that the hybrid construction offered a less expensive and more viable option for single-level lumbar fusion [14]. Jang and Lee published their pilot clinical studies of the unilateral pedicle screw (PS)-based and contralateral facet screw (FS)-based TLIF techniques, and they indicated that TLIF with ipsilateral PS and contralateral FS fixation offered reduced blood loss and soft-tissue injury compared with the conventional TLIF [32].

Researchers have attempted to achieve satisfactory lumbar fusion with MIS techniques while reducing injury and implant costs [42]. The morbidity associated with open TLIF is extensive, and prolonged muscle ischemia occurs as a result of the extensive muscle stripping and retraction that occurs during the surgical approach [43, 44]. The MIS TLIF procedure is used to achieve solid lumbar interbody fusion via a unilateral posterolateral approach, and it has gained recent popularity because it results in smaller wounds, less tissue trauma, and faster recovery [45, 46]. However, wide exposure and expensive implants are required for the insertion of the percutaneous pedicle screws in standard MIS TLIF [14, 32]. In addition, the soft-tissue injuries caused by the insertion of percutaneous pedicle screws include damage to muscles, the adjacent facet, and ligaments. The procedure can cause increased blood loss, infection rate, and postoperative back pain; a longer recovery period; and impaired fusion [30, 44, 47].

For the disadvantages previously mentioned above, we performed MIS TLIF in 58 patients using a hybrid internal fixation system consisting of unilateral pedicle screws and a contralateral translaminar facet screw. The technique of MIS TLIF used in this study was quite different from the standard MIS TLIF [14, 32], and our result revealed that it is characterized by a small incision, reduced trauma, simple operation, high safety, good stability, high fusion rate, and few complications. And we determined that it is feasible and safe to insert a translaminar facet screw under direct vision via a single small incision and that there was no decrease in stiffness or effectiveness compared with the conventional bilateral PSF procedure. Because the anatomical structures surrounding the canal created for the translaminar facet screw include the posterior muscle, the anterior ligamentum flavum, and the superior and inferior pedicle cortical bone, there is a relatively extensive safe area for the insertion of the translaminar facet screw. This safety statement was also justified by the fact that in our study, two (3.6%) translaminar facet screws penetrated the lateral lamina and two (3.6%) translaminar facet screws penetrated the medial lamina with no serious neural complications. Additionally, there was a relatively steep learning curve for this technique.

However, there are several limitations to this current study. Firstly, it is a retrospective investigation, which cannot avoid selection and recall bias completely, despite our trying our best to collect and analyze the data meticulously throughout the study. Secondly, the patients with bilateral radicular symptoms were not included. In fact, our group has already adopted this technique to treat patients with bilateral symptoms and two segment degenerative lumbar disease. Next, we will report the preliminary result of this aspect of the research. Last, but not the least, the sample size in this study was relatively small and the follow-up time of 29.9 months was relatively short to observe the long-term clinical outcome. And it is just a preliminary clinical study about the feasibility of this surgical technique and a clinical result. In the future, well-designed prospective studies with a larger study population and longer follow-up time should be conducted to determine the clinical and radiographic significance of the MIS TLIF technique compared with bilateral PSF technique and other internal fixation methods, providing a convincing evidence-based conclusion.

Conclusion

We have introduced the MIS TLIF technique using a hybrid internal fixation system constructed with unilateral pedicle screws and a contralateral translaminar facet screw which was different from the conventional MIS TLIF. The MIS TLIF technique is safe and effective in the treatment of single-segment lower lumbar vertebral disease, and it can be used as an optimal choice for the fixation and fusion of some single-segment lower lumbar vertebral diseases.

Abbreviations

CT:

Computed tomography

ODI:

Oswestry Disability Index

PSF:

Pedicle screw fixation

TFSF:

Translaminar facet screw fixation

TLIF:

Transforaminal lumbar interbody fusion

VAS:

Visual analog scale

References

  1. Glaser J, Stanley M, Sayre H, Woody J, Found E, Spratt K. A 10-year follow-up evaluation of lumbar spine fusion with pedicle screw fixation. Spine (Phila Pa 1976). 2003;28(13):1390–5.

    Google Scholar 

  2. Brantigan JW, Neidre A, Toohey JS. The Lumbar I/F Cage for posterior lumbar interbody fusion with the variable screw placement system: 10-year results of a Food and Drug Administration clinical trial. Spine J. 2004;4(6):681–8.

    Article  PubMed  Google Scholar 

  3. Cheh G, Bridwell KH, Lenke LG, et al. Adjacent segment disease following lumbar/thoracolumbar fusion with pedicle screw instrumentation: a minimum 5-year follow-up. Spine (Phila Pa 1976). 2007;32(20):2253–7.

    Article  Google Scholar 

  4. Oh HS, Kim JS, Lee SH, Liu WC, Hong SW. Comparison between the accuracy of percutaneous and open pedicle screw fixations in lumbosacral fusion. Spine J. 2013;13(12):1751–7.

    Article  PubMed  Google Scholar 

  5. Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew KD. Free hand pedicle screw placement in the thoracic spine: is it safe. Spine (Phila Pa 1976). 2004;29(3):333–42. discussion 342.

    Article  Google Scholar 

  6. Gertzbein SD, Robbins SE. Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976). 1990;15(1):11–4.

    Article  CAS  Google Scholar 

  7. Kim CW, Lee YP, Taylor W, Oygar A, Kim WK. Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally invasive spine surgery. Spine J. 2008;8(4):584–90.

    Article  PubMed  Google Scholar 

  8. Tuli J, Tuli S, Eichler ME, Woodard EJ. A comparison of long-term outcomes of translaminar facet screw fixation and pedicle screw fixation: a prospective study. J Neurosurg Spine. 2007;7(3):287–92.

    Article  PubMed  Google Scholar 

  9. Zeng ZY, Wu P, Mao KY, et al. Unilateral pedicle screw fixation versus its combination with contralateral translaminar facet screw fixation for the treatment of single segmental lower lumbar vertebra diseases. Zhongguo Gu Shang. 2015;28(4):306–12.

    PubMed  Google Scholar 

  10. Park P, Garton HJ, Gala VC, Hoff JT, Mcgillicuddy JE. Adjacent segment disease after lumbar or lumbosacral fusion: review of the literature. Spine (Phila Pa 1976). 2004;29(17):1938–44.

    Article  Google Scholar 

  11. Zencica P, Chaloupka R, Hladíková J, Krbec M. Adjacent segment degeneration after lumbosacral fusion in spondylolisthesis: a retrospective radiological and clinical analysis. Acta Chir Orthop Traumatol Cech. 2010;77(2):124–30.

    CAS  PubMed  Google Scholar 

  12. Suk KS, Lee HM, Kim NH, Ha JW. Unilateral versus bilateral pedicle screw fixation in lumbar spinal fusion. Spine (Phila Pa 1976). 2000;25(14):1843–7.

    Article  CAS  Google Scholar 

  13. Feng ZZ, Cao YW, Jiang C, Jiang XX. Short-term outcome of bilateral decompression via a unilateral paramedian approach for transforaminal lumbar interbody fusion with unilateral pedicle screw fixation. Orthopedics. 2011;34(5):364.

    PubMed  Google Scholar 

  14. Sethi A, Lee S, Vaidya R. Transforaminal lumbar interbody fusion using unilateral pedicle screws and a translaminar screw. Eur Spine J. 2009;18(3):430–4.

    Article  PubMed  Google Scholar 

  15. Kabins MB, Weinstein JN, Spratt KF, et al. Isolated L4-L5 fusions using the variable screw placement system: unilateral versus bilateral. J Spinal Disord. 1992;5(1):39–49.

    Article  CAS  PubMed  Google Scholar 

  16. Harris BM, Hilibrand AS, Savas PE, et al. Transforaminal lumbar interbody fusion: the effect of various instrumentation techniques on the flexibility of the lumbar spine. Spine (Phila Pa 1976). 2004;29(4):E65–70.

    Article  Google Scholar 

  17. Kasai Y, Inaba T, Kato T, Matsumura Y, Akeda K, Uchida A. Biomechanical study of the lumbar spine using a unilateral pedicle screw fixation system. J Clin Neurosci. 2010;17(3):364–7.

    Article  PubMed  Google Scholar 

  18. Slucky AV, Brodke DS, Bachus KN, Droge JA, Braun JT. Less invasive posterior fixation method following transforaminal lumbar interbody fusion: a biomechanical analysis. Spine J. 2006;6(1):78–85.

    Article  PubMed  Google Scholar 

  19. Goel VK, Lim TH, Gwon J, et al. Effects of rigidity of an internal fixation device. A comprehensive biomechanical investigation. Spine (Phila Pa 1976). 1991;16(3 Suppl):S155–61.

    Article  CAS  Google Scholar 

  20. Aepli M, Mannion AF, Grob D. Translaminar screw fixation of the lumbar spine: long-term outcome. Spine (Phila Pa 1976). 2009;34(14):1492–8.

    Article  Google Scholar 

  21. Pavlov PW, Meijers H, van Limbeek J, et al. Good outcome and restoration of lordosis after anterior lumbar interbody fusion with additional posterior fixation. Spine (Phila Pa 1976). 2004;29(17):1893–9. discussion 1900.

    Article  Google Scholar 

  22. King D. Internal fixation for lumbosacral fusion. J Bone Joint Surg Am. 1948;30A(3):560–5.

    Article  CAS  PubMed  Google Scholar 

  23. Magerl FP. Stabilization of the lower thoracic and lumbar spine with external skeletal fixation. Clin Orthop Relat Res. 1984;189:125–41.

    Google Scholar 

  24. Montesano PX, Magerl F, Jacobs RR, Jackson RP, Rauschning W. Translaminar facet joint screws. Orthopedics. 1988;11(10):1393–7.

    CAS  PubMed  Google Scholar 

  25. Reich SM, Kuflik P, Neuwirth M. Translaminar facet screw fixation in lumbar spine fusion. Spine (Phila Pa 1976). 1993;18(4):444–9.

    Article  CAS  Google Scholar 

  26. Best NM, Sasso RC. Efficacy of translaminar facet screw fixation in circumferential interbody fusions as compared to pedicle screw fixation. J Spinal Disord Tech. 2006;19(2):98–103.

    Article  PubMed  Google Scholar 

  27. Grob D, Bartanusz V, Jeszenszky D, et al. A prospective, cohort study comparing translaminar screw fixation with transforaminal lumbar interbody fusion and pedicle screw fixation for fusion of the degenerative lumbar spine. J Bone Joint Surg Br. 2009;91(10):1347–53.

    Article  CAS  PubMed  Google Scholar 

  28. Jang JS, Lee SH, Lim SR. Guide device for percutaneous placement of translaminar facet screws after anterior lumbar interbody fusion. Technical note. J Neurosurg. 2003;98(1 Suppl):100–3.

    PubMed  Google Scholar 

  29. Humke T, Grob D, Dvorak J, Messikommer A. Translaminar screw fixation of the lumbar and lumbosacral spine. A 5-year follow-up. Spine (Phila Pa 1976). 1998;23(10):1180–4.

    Article  CAS  Google Scholar 

  30. Kawaguchi Y, Matsui H, Tsuji H. Back muscle injury after posterior lumbar spine surgery. A histologic and enzymatic analysis. Spine (Phila Pa 1976). 1996;21(8):941–4.

    Article  CAS  Google Scholar 

  31. Deguchi M, Cheng BC, Sato K, Matsuyama Y, Zdeblick TA. Biomechanical evaluation of translaminar facet joint fixation. A comparative study of poly-L-lactide pins, screws, and pedicle fixation. Spine (Phila Pa 1976). 1998;23(12):1307–12. Discussion 1313.

    Article  CAS  Google Scholar 

  32. Jang JS, Lee SH. Minimally invasive transforaminal lumbar interbody fusion with ipsilateral pedicle screw and contralateral facet screw fixation. J Neurosurg Spine. 2005;3(3):218–23.

    Article  PubMed  Google Scholar 

  33. Eskander M, Brooks D, Ordway N, Dale E, Connolly P. Analysis of pedicle and translaminar facet fixation in a multisegment interbody fusion model. Spine (Phila Pa 1976). 2007;32(7):E230–5.

    Article  Google Scholar 

  34. Schleicher P, Beth P, Ottenbacher A, et al. Biomechanical evaluation of different asymmetrical posterior stabilization methods for minimally invasive transforaminal lumbar interbody fusion. J Neurosurg Spine. 2008;9(4):363–71.

    Article  PubMed  Google Scholar 

  35. Zeng ZY, Zhang JQ, Song YX, et al. Combination of percutaneous unilateral translaminar facet screw fixation and interbody fusion for treatment of lower lumbar vertebra diseases: a follow-up study. Orthop Surg. 2014;6(2):110–7.

    Article  PubMed  Google Scholar 

  36. Bridwell KH, Lenke LG, McEnery KW, Baldus C, Blanke K. Anterior fresh frozen structural allografts in the thoracic and lumbar spine. Do they work if combined with posterior fusion and instrumentation in adult patients with kyphosis or anterior column defects. Spine (Phila Pa 1976). 1995;20(12):1410–8.

    Article  CAS  Google Scholar 

  37. Kim KT, Lee SH, Lee YH, Bae SC, Suk KS. Clinical outcomes of 3 fusion methods through the posterior approach in the lumbar spine. Spine (Phila Pa 1976). 2006;31(12):1351–7. discussion 1358.

    Article  Google Scholar 

  38. Zeng ZY, Wu P, Yan WF, et al. Mixed fixation and interbody fusion for treatment single-segment lower lumbar vertebral disease: midterm follow-up results. Orthop Surg. 2015;7(4):324–32.

    Article  PubMed  Google Scholar 

  39. Bagan B, Patel N, Deutsch H, Harrop J, Sharan A, Vaccaro AR, et al. Perioperative complications of minimally invasive surgery (MIS): comparison of MIS and open interbody fusion techniques. Surg Technol Int. 2008;17:281–6.

    PubMed  Google Scholar 

  40. Pihlajämaki H, Myllynen P, Böstman O. Complications of transpedicular lumbosacral fixation for non-traumatic disorders. J Bone Joint Surg Br. 1997;79(2):183–9.

    Article  PubMed  Google Scholar 

  41. Castro WH, Halm H, Jerosch J, Malms J, Steinbeck J, Blasius S. Accuracy of pedicle screw placement in lumbar vertebrae. Spine (Phila Pa 1976). 1996;21(11):1320–4.

    Article  CAS  Google Scholar 

  42. Cao Y, Chen Z, Jiang C, Wan S, Jiang X, Feng Z. The combined use of unilateral pedicle screw and contralateral facet joint screw fixation in transforaminal lumbar interbody fusion. Eur Spine J. 2015;24:2607–13.

    Article  PubMed  Google Scholar 

  43. Rosenberg WS, Mummaneni PV. Transforaminal lumbar interbody fusion: technique, complications, and early results. Neurosurgery. 2001;48(3):569–74. discussion 574–5.

    Article  CAS  PubMed  Google Scholar 

  44. Gejo R, Matsui H, Kawaguchi Y, Ishihara H, Tsuji H. Serial changes in trunk muscle performance after posterior lumbar surgery. Spine (Phila Pa 1976). 1999;24(10):1023–8.

    Article  CAS  Google Scholar 

  45. Foley KT, Holly LT, Schwender JD. Minimally invasive lumbar fusion. Spine (Phila Pa 1976). 2003;28:S26–35.

  46. Humphreys SC, Hodges SD, Patwardhan AG, Eck JC, Murphy RB, Covington LA. Comparison of posterior and transforaminal approaches to lumbar interbody fusion. Spine (Phila Pa 1976). 2001;26(5):567–71.

    Article  CAS  Google Scholar 

  47. Rantanen J, Hurme M, Falck B, et al. The lumbar multifidus muscle five years after surgery for a lumbar intervertebral disc herniation. Spine (Phila Pa 1976). 1993;18(5):568–74.

    Article  CAS  Google Scholar 

Download references

Acknowledgements

This research was performed mainly at the Department of Orthopaedics of the Chinese PLA General Hospital.

Funding

This work was supported by the Project of the National Natural Science Foundation (51372276) and the 12th Five-Year Military Medicine and Health Project (CWS11J110).

Availability of data and materials

The datasets during and/or analyzed during the current study are available from the corresponding author on reasonable request.

Author information

Authors and Affiliations

Authors

Contributions

PH and KM designed the study. YW carried out the study and collected the crucial background information. JX and JL collected the data. BX analyzed the data. JL interpreted the data. PH composed the article. LC did the figure editing. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Keya Mao.

Ethics declarations

Peng Huang is the first author and Keya Mao is the corresponding author.

Ethics approval and consent to participate

This study has been approved by the Ethics Committee of the Chinese PLA General Hospital, and the approval number is K2010-011-02. Written informed consent was obtained from each patient prior to the study.

Consent for publication

All patients included into the study provided their informed consent at enrolment on the use of patients’ data for research.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Huang, P., Wang, Y., Xu, J. et al. Minimally invasive unilateral pedicle screws and a translaminar facet screw fixation and interbody fusion for treatment of single-segment lower lumbar vertebral disease: surgical technique and preliminary clinical results. J Orthop Surg Res 12, 117 (2017). https://doi.org/10.1186/s13018-017-0606-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13018-017-0606-z

Keywords