Laroche M: Intraosseous circulation from physiology to disease. Joint Bone Spine. 2002, 69: 262-269. 10.1016/S1297-319X(02)00391-3.
Article
PubMed
Google Scholar
Nuutila P, Kalliokoski K: Use of positron emission tomography in the assessment of skeletal muscle and tendon metabolism and perfusion. Scand J Med Sci Sports. 2000, 10: 346-350. 10.1034/j.1600-0838.2000.010006346.x.
Article
CAS
PubMed
Google Scholar
Raitakari M, Nuutila P, Ruotsalainen U, Teras M, Eronen E, Laine H, Raitakari OT, Iida H, Knuuti MJ, Yki-Jarvinen H: Relationship between limb and muscle blood flow in man. J Physiol. 1996, 496 ( Pt 2): 543-549.
Article
CAS
Google Scholar
Kubo T, Kimori K, Nakamura F, Inoue S, Fujioka M, Ueshima K, Hirasawa Y, Ushijima Y, Nishimura T: Blood flow and blood volume in the femoral heads of healthy adults according to age: measurement with positron emission tomography (PET). Ann Nucl Med. 2001, 15: 231-235.
Article
CAS
PubMed
Google Scholar
Iida S, Harada Y, Ikenoue S, Moriya H: Measurement of bone marrow blood volume in the knee by positron emission tomography. J Orthop Sci. 1999, 4: 216-222. 10.1007/s007760050096.
Article
CAS
PubMed
Google Scholar
Binzoni T, Leung T, Hollis V, Bianchi S, Fasel JH, Bounameaux H, Hiltbrand E, Delpy D: Human tibia bone marrow: defining a model for the study of haemodynamics as a function of age by near infrared spectroscopy. J Physiol Anthropol Appl Human Sci. 2003, 22: 211-218. 10.2114/jpa.22.211.
Article
PubMed
Google Scholar
Kane WJ: Fundamental concepts in bone-blood flow studies. J Bone Joint Surg Am. 1968, 50: 801-811.
CAS
PubMed
Google Scholar
Shim SS: Physiology of blood circulation of bone. J Bone Joint Surg Am. 1968, 50: 812-824.
CAS
PubMed
Google Scholar
Swiontkowski MF, Tepic S, Perren SM, Moor R, Ganz R, Rahn BA: Laser Doppler flowmetry for bone blood flow measurement: correlation with microsphere estimates and evaluation of the effect of intracapsular pressure on femoral head blood flow. J Orthop Res. 1986, 4: 362-371. 10.1002/jor.1100040313.
Article
CAS
PubMed
Google Scholar
Anetzberger H, Thein E, Becker M, Walli AK, Messmer K: Validity of fluorescent microspheres method for bone blood flow measurement during intentional arterial hypotension. J Appl Physiol. 2003, 95: 1153-1158.
Article
CAS
PubMed
Google Scholar
Anetzberger H, Thein E, Maier M, Birkenmaier C, Messmer K: Fluorescent microspheres are reliable for serial bone blood flow measurements. Clin Orthop Relat Res. 2004, 241-248. 10.1097/01.blo.0000136833.02449.2a.
Google Scholar
Anetzberger H, Thein E, Loffler G, Messmer K: Fluorescent microsphere method is suitable for chronic bone blood flow measurement: a long-term study after meniscectomy in rabbits. J Appl Physiol. 2004, 96: 1928-1936. 10.1152/japplphysiol.00904.2003.
Article
CAS
PubMed
Google Scholar
Anetzberger H, Thein E, Becker M, Zwissler B, Messmer K: Microspheres accurately predict regional bone blood flow. Clin Orthop Relat Res. 2004, 253-265. 10.1097/01.blo.0000128281.67589.b4.
Google Scholar
ElMaraghy AW, Humeniuk B, Anderson GI, Schemitsch EH, Richards RR: Femoral bone blood flow after reaming and intramedullary canal preparation: a canine study using laser Doppler flowmetry. J Arthroplasty. 1999, 14: 220-226. 10.1016/S0883-5403(99)90130-4.
Article
CAS
PubMed
Google Scholar
Fleming JT, Barati MT, Beck DJ, Dodds JC, Malkani AL, Parameswaran D, Soukhova GK, Voor MJ, Feitelson JB: Bone blood flow and vascular reactivity. Cells Tissues Organs. 2001, 169: 279-284. 10.1159/000047892.
Article
CAS
PubMed
Google Scholar
Notzli HP, Swiontkowski MF, Thaxter ST, Carpenter GK, Wyatt R: Laser Doppler flowmetry for bone blood flow measurements: helium-neon laser light attenuation and depth of perfusion assessment. J Orthop Res. 1989, 7: 413-424. 10.1002/jor.1100070314.
Article
CAS
PubMed
Google Scholar
Rhinelander FW: Tibial blood supply in relation to fracture healing. Clin Orthop Relat Res. 1974, 34-81.
Google Scholar
Keidar Z, Israel O, Krausz Y: SPECT/CT in tumor imaging: technical aspects and clinical applications. Semin Nucl Med. 2003, 33: 205-218. 10.1053/snuc.2003.127310.
Article
PubMed
Google Scholar
Hokanson DE, Sumner DS, Strandness DE: An electrically calibrated plethysmograph for direct measurement of limb blood flow. IEEE Trans Biomed Eng. 1975, 22: 25-29. 10.1109/TBME.1975.324535.
Article
CAS
PubMed
Google Scholar
Patrick ST, Glowniak JV, Turner FE, Robbins MS, Wolfangel RG: Comparison of in vitro RBC labeling with the UltraTag RBC kit versus in vivo labeling. J Nucl Med. 1991, 32: 242-244.
CAS
PubMed
Google Scholar
Brinker MR, Lippton HL, Cook SD, Hyman AL: Pharmacological regulation of the circulation of bone. J Bone Joint Surg Am. 1990, 72: 964-975.
CAS
PubMed
Google Scholar
Frost ML, Cook GJ, Blake GM, Marsden PK, Benatar NA, Fogelman I: A prospective study of risedronate on regional bone metabolism and blood flow at the lumbar spine measured by 18F-fluoride positron emission tomography. J Bone Miner Res. 2003, 18: 2215-2222. 10.1359/jbmr.2003.18.12.2215.
Article
CAS
PubMed
Google Scholar
Guyton A 1996 Local control of blood flow by the tissues.In: Guyton H 9th ed. Saunders, Philadelphia, pp.199-208.
Google Scholar
McCarthy I: The physiology of bone blood flow: a review. J Bone Joint Surg Am. 2006, 88 Suppl 3: 4-9. 10.2106/JBJS.F.00890.
Article
PubMed
Google Scholar