Table 4 Comparison of subjects’ bilateral wearable gait sensor measurement metrics

From: The effect of harvesting the anterior half of the peroneus longus tendon on foot morphology and gait

Subject

Operative side

Healthy side

Test value

P value

Average value

(Statistics) standard deviation

Average value

(Statistics) standard deviation

Touchdown phase (%)

10.95

2.34

11.87

1.66

3.47

0.003

Mid-stance phase (%)

30.29

4.21

29.47

3.33

− 58

0.030

Propulsion phase (%)

17.10

2.75

18.34

2.79

84

< .001

Stance phase (%)

58.34

4.90

59.68

4.34

47

0.083

Swing phase (%)

41.66

4.90

40.32

4.34

− 47

0.083

Frequency of steps

80.31

20.09

83.12

10.45

7.5

0.738

Stride length

108.25

13.88

109.84

13.07

0.61

0.549

Touchdown period—touchdown elevation angle (°)

11.06

4.84

13.02

4.94

2.55

0.019

End of propulsive phase—propulsive pitch angle (°)

44.60

7.70

49.80

5.38

4.07

< .001