From: A retrospective comparison of double-hooked locking plates versus non-locking plates in minimally invasive percutaneous plate osteosynthesis for the treatment of comminuted distal fibular fractures accompanied by tibial Pilon fractures
Excellent
Good
Acceptable
Poor
Excellent rate (%)
χ2
P
Control group (n = 48)
14
22
7
5
75.00
6.544
0.011
Study group (n = 48)
26
19
3
0
93.75