From: Distal osteotomy of the first metatarsal bone for the correction of hallux valgus: comparison of the sagittal stability of two percutaneous techniques—a cadaveric study
Axial load (kg)
Bösch
Chevron
Significance
10
−4.3 ± 4.2
0.5 ± 1.8
P 0.031
20
−2.9 ± 0.8
0.3 ± 1.3
P 0.04
30
−3.2 ± 3.5
−0.7 ± 2.8
P 0.114
40
−2.5 ± 3.3
−0.5 ± 2.8
P 0.150
50
−2.2 ± 3.2
−0.6 ± 2.5
P 0.227
60
−2.2 ± 3.6
−0.1 ± 2.3
P 0.143