From: Distal osteotomy of the first metatarsal bone for the correction of hallux valgus: comparison of the sagittal stability of two percutaneous techniques—a cadaveric study
Axial load (kg)
Bösch
Chevron
Significance
10
−0.8 ± 17.6
−7.3 ± 9.6
P 0.453
20
−4.3 ± 15.7
−8.4 ± 7.1
P 0.516
30
−4.1 ± 17.8
−8.3 ± 8.1
P 0.517
40
−4.7 ± 16.4
−9.1 ± 8.1
P 0.458
50
−6.5 ± 12.8
−9.2 ± 11.6
P 0.628
60
−6.8 ± 13.3
−7.8 ± 12.9
P 0.867