Table 4 Standard values and the accepted range of each lower limb parameter [12, 18], interobserver-ICC2,1, Standard Error of Measurement (SEM) and proportional error

From: Intra- and interobserver reliability analysis of pediatric lower limb parameters on digital long leg radiographs

Measures

Standard value

Accepted range

Interobserver-ICC2,1

SEM95%

SEM95%Range

Proportional error in %

MFA (°)

1.3 ± 3

6

0.949 (0.859–0.975)

 ± 1.39

2.78

46.33

MAD (mm)

8 ± 7

14

0.976 (0.966–0.983)

 ± 3.31

6.62

47.29

mLPFA (°)

90 ± 5

10

0.974 (0.964–0.981)

 ± 1.69

3.38

33.80

mLDFA (°)

88 ± 2.5

5

0.969 (0.954–0.979)

 ± 1.06

2.12

42.40

mMPTA (°)

87 ± 2.5

5

0.864 (0.816–0.901)

 ± 1.29

2.58

51.60

mLDTA (°)

89 ± 3

6

0.876 (0.831–0.909)

 ± 2.17

4.34

72.33

JLCA (°)

1 ± 1

2

0.488 (0.350–0.605)

 ± 1.38

2.76

138.00

Femur length (mm)

N/A

N/A

0.996 (0.994–0.997)

 ± 4.53

N/A

N/A

Tibia length (mm)

N/A

N/A

0.994 (0.990–0.998)

 ± 3.12

N/A

N/A

  1. Interobserver-ICC2,1 (95% confidence interval in parenthesis) with Standard Error of Measurement (SEM) with a 95% confidence interval. For interobserver-ICC2,1 first measurement results of observer 1 were compared with first measurement results of observer 2
  2. MFA Mechanical Femorotibial Angle; MAD Mechanical Axis Deviation; mLPFA mechanical Lateral Proximal Femur Angle; mLDFA mechanical Lateral Distal Femur Angle; mMPTA mechanical Medial Proximal Tibia Angle; mLDTA mechanical Lateral Distal Tibia Angle; JLCA Joint Line Convergence Angle, length of the femur and tibia
  3. For values of femur length and tibia length there are no standard values and therefore no accepted ranges, SEM95%Range or proportional errors are not applicable (N/A)