Patients | Cup accuracy (N = 391) | Stem accuracy (N = 346) | |||||
---|---|---|---|---|---|---|---|
± 0 | ± 1 | ± 2 | ± 0 | ± 1 | ± 2 | ||
Total | 391 (100%) | 28.9% | 63.9% | 83.1% | 27.2% | 61.0% | 78.6% |
Nominal variables | |||||||
Year | |||||||
2018 | 67 (17.1%) | 26.9% | 61.2% | 82.1% | 32.7% | 75.0% | 88.5% |
2019 | 122 (31.2%) | 33.6% | 66.4% | 86.9% | 28.2% | 60.0% | 82.7% |
2020 | 139 (35.5%) | 26.6% | 63.3% | 80.6% | 23.8% | 54.8% | 71.4% |
2021 | 63 (16.1%) | 27% | 63.5% | 82.5% | 27.6% | 63.8% | 77.6% |
P value* | 0.590 | 0.904 | 0.585 | 0.663 | 0.087 | 0.046 (post-hoc analysis revealed no significance) | |
Gender | |||||||
Male | 193 (49.4%) | 30.1% | 65.8% | 85.0% | 20.8% | 53.8% | 76.3% |
Female | 198 (50.6%) | 27.8% | 62.1% | 81.3% | 33.5% | 68.2% | 80.9% |
P value* | 0.620 | 0.448 | 0.334 | 0.008 | 0.006 | 0.294 | |
Indication for surgery | |||||||
AVN | 100 (25.6%) | 24.0% | 69.0% | 83.0% | 18.8% | 49.0% | 70.8% |
DDH | 198 (50.6%) | 31.8% | 65.7% | 86.9% | 32.2% | 70.7%*** | 84.5% |
DJD | 37 (9.5%) | 27.0% | 64.9% | 81.1% | 28.6% | 60.7% | 75.0% |
Fracture | 19 (4.9%) | 21.1% | 47.4% | 84.2% | 23.5% | 58.8% | 70.6% |
Revision | 24 (6.1%) | 41.7% | 54.2% | 62.5%*** | 22.2% | 44.4% | 72.2% |
Other (acetabular fracture N = 1, hip fusion N = 2, hemophilia DJD N = 1, perthes N = 6, septic arthritis N = 3) | 13 (3.3%) | 15.4% | 38.5% | 69.2% | 30.8% | 46.2% | 84.6% |
P value* | 0.339 | 0.141 | 0.048 | 0.297 | 0.007 | 0.126 | |
Stem brand (N = 391, 346 was considered for accuracy estimation) | |||||||
Fitmore® | 120 (27.8%) | 22.5% | 65.0% | 84.2% | 21.2% | 45.2%*** | 71.2% |
Fitmore® extended | 71 (16.5%) | 26.8% | 62.0% | 84.5% | 25.7% | 60.0% | 77.1% |
M/L taper | 51 (11.8%) | 29.4% | 62.7% | 86.3% | 34.8% | 67.4% | 82.6% |
Wagner Cone® | 48 (11.1%) | 52.1%*** | 72.9% | 87.5% | 41.7% | 81.3%*** | 91.7% |
Accolade® **** | 11 (2.6%) | 9.1% | 36.4% | 72.7% | – | – | – |
CORAIL® | 61 (14.2%) | 24.6% | 67.2% | 82.0% | 23.7% | 72.9% | 83.1% |
Müller™ **** | 2 (0.5%) | 0.0% | 100.0% | 100.0% | – | – | – |
Wagner SL revision® | 21 (4.9%) | 38.1% | 42.9% | 61.9% | 21.1% | 47.4% | 68.4% |
Unknown brand (lack of data) | 6 (1.5%) | – | – | – | – | – | – |
P value* | 0.006 | 0.153 | 0.321 | 0.104 | 0.001 < | 0.058 | |
Cup brand | |||||||
Continuum® | 226 (52.4%) | 31.4% | 60.2% | 82.3% | 30.1% | 61.2% | 78.5% |
PINNACLE® | 63 (14.6%) | 25.4% | 66.7% | 81.0% | 23.0% | 72.1% | 82.0% |
Trident® | 11 (2.6%) | 9.1% | 36.4% | 72.7% | – | – | – |
Trilogy® | 81 (18.8%) | 28.4% | 76.5% | 88.9% | 25.4% | 49.3% | 77.6% |
Trilogy® IT | 7 (1.6%) | 14.3% | 57.1% | 85.7% | 0.0% | 57.1% | 57.1% |
Other (cage N = 1, shell N = 1, Dual mobility N = 1) | 3 (0.7%) | 33.3% | 66.7% | 66.7% | 0.0% | 100.0% | 100.0% |
P value* | 0.558 | 0.052 | 0.593 | 0.292 | 0.078 | 0.572 | |
Continuous variables (mean of variable in the accurate group versus inaccurate group) | |||||||
Age (mean ± SD) | 44.7 ± 13.8 versus 42.8 ± 15.3 | 43.9 ± 14.1 versus 42.3 ± 16.3 | 43.5 ± 14.8 versus 42.2 ± 15.5 | 41.2 ± 14.2 versus 43.4 ± 15.0 | 42.2 ± 14.6 versus 43.8 ± 15.1 | 42.5 ± 14.7 versus 44.1 ± 15.2 | |
P value** | 0.252 | 0.332 | 0.508 | 0.216 | 0.313 | 0.410 | |
BMI (Kg m−2, mean) | 25.0 ± 4.0 versus 24.5 ± 4.5 | 24.4 ± 4.2 versus 25.0 ± 4.6 | 24.5 ± 4.4 versus 25.2 ± 4.3 | 24.5 ± 4.3 versus 24.6 ± 4.3 | 24.5 ± 3.9 versus 24.5 ± 4.6 | 24.4 ± 4.4 versus 24.9 ± 3.8 | |
P value** | 0.249 | 0.183 | 0.243 | 0.919 | 0.972 | 0.428 | |
Cup diameter (mm, mean) | 51.2 ± 4.5 versus 52.5 ± 4.1 | 51.9 ± 4.1 versus 52.5 ± 5.6 | 52.0 ± 4.2 versus 52.6 ± 4.7 | 51.1 ± 4.4 versus 52.5 ± 4.2 | 51.5 ± 4.4 versus 53.1 ± 3.9 | 51.8 ± 4.4 versus 53.2 ± 3.8 | |
P value** | 0.007 | 0.195 | 0.346 | 0.008 | 0.001 > | 0.012 |