Table 3 Stiffness of simple intra-articular fracture of the distal humerus models under different testing conditions

From: Biomechanical properties of a novel fixation system for intra-articular distal humerus fractures: a finite element analysis

Configuration

Axial (N/mm)

Bending (N/mm)

Rotational torsion (N mm/°)

Novel plating

142.86

37.97

2840.91

Orthogonal plating

121.21

32.61

1968.50