Skip to main content

Table 3 Intraoperative outcome

From: Spacer-based gap balancing is useful in total knee arthroplasty: a 3-year follow-up of a retrospective study

 

GB group (n = 61)

MR group (n = 63)

P value

Operative time (min)

76.25 ± 12.43

80.25 ± 12.44

0.075

Blood loss (ml)

55.33 ± 11.06

57.78 ± 12.50

0.251

External rotation of femur (°) relative to PCA

4.06 ± 1.10

3.19 ± 0.59

< 0.001

Posterior medial condyle cut thickness (mm)

9.72 ± 0.84

9.25 ± 0.62

0.001

Posterior lateral condyle cut thickness (mm)

6.91 ± 0.71

7.08 ± 0.53

0.135