Skip to main content

Table 3 Comparison of radiographic parameters, functional outcomes, and complications between two groups at the last visit (> 12 months)

From: Comparison of radiographic and functional results of die-punch fracture of distal radius between volar locking plating (VLP) and external fixation (EF)

Variable

VLP

External fixation

p

Volar tilt (°)

5.7 (4.5)

5.3 (3.9)

0.528

Radial inclination (°)

22.6 (3.7)

21.4 (3.2)

0.318

Radial height (mm)

10.7 (1.2)

10.4 (1.4)

0.803

Ulnar variance (mm)

0.8 (1.1)

0.8 (0.9)

0.912

Articular step-off (mm)

0.3 (0.5)

0.6 (0.4)

0.003

DASH (points)

8.5 (9.7)

10.7 (12.0)

0.072

Gartland–Werley score (points)

4.9 (3.4)

5.3 (2.7)

0.173

Overall complications

9 (100)

6 (100)

0.237

 Tendon complications

3 (37.5)

1 (20.0)

 

 Infection

0

2 (40.0)

 

 Traumatic osteoarthritis

0

1 (20.0)

 

 Neuropathy or nerve injury

1 (12.5)

1

 

 Hardware failure

1 (12.5)

0

 

 Complex regional pain syndrome Type I (CRPS)

2 (37.5)

1 (20.0)

 

Carpal tunnel syndrome

2

0