Skip to main content

Table 2 Test-retest results of goniometer and 3D motion analysis measurement

From: Minimal detectable difference of the finger and wrist range of motion: comparison of goniometry and 3D motion analysis

  

Motion Capture

Goniometer

Joint

Direction

n V

MDDV

SEMV

ICCV

PDV < 5°

PDV < 10°

n G

MDDG

SEMG

ICCG

PDG < 5°

PDG < 10°

[°]

[°]

[%]

[%]

[°]

[°]

[%]

[%]

Radioulnar

P/S

16

8

3.0

0.94

69

100

20

19

6.8

0.35

45

65

Wrist

F/E

20

6

2.1

0.97

95

100

20

18

6.4

0.87

50

75

Wrist

R/U

20

7

2.6

0.90

90

95

20

18

6.5

0.72

55

65

MCP2

F/E

20

7

2.7

0.96

80

100

20

19

7.0

0.79

25

60

MCP3

F/E

20

9

3.1

0.95

65

100

20

24

8.8

0.59

35

60

MCP4

F/E

19

9

3.4

0.92

47

100

20

18

6.6

0.81

40

60

MCP5

F/E

18

16

5.7

0.90

33

72

20

22

8.0

0.86

20

40

PIP2

F/E

20

8

3.0

0.85

85

95

20

12

4.2

0.66

55

80

PIP3

F/E

20

12

4.2

0.66

65

85

20

12

4.3

0.64

55

80

PIP4

F/E

20

10

3.8

0.86

80

85

20

13

4.6

0.60

60

75

PIP5

F/E

20

11

4.0

0.85

65

90

20

15

5.5

0.40

45

65

DIP2

F/E

20

9

3.4

0.92

65

90

20

14

5.0

0.79

45

80

DIP3

F/E

20

9

3.3

0.92

60

100

20

18

6.7

0.75

30

60

DIP4

F/E

20

10

3.5

0.96

70

95

20

17

6.3

0.84

40

65

DIP5

F/E

19

11

4.0

0.94

58

95

20

14

4.9

0.86

60

85

IP

F/E

20

14

5.0

0.93

50

80

20

30

11.0

0.85

35

50

MCP1

F/E

19

14

5.0

0.91

68

79

20

19

6.8

0.83

30

70