From: Clinical outcomes of femoral shaft non-union: dual plating versus exchange nailing with augmentation plating
Variable
EN + AP group
DP group
p value
Length of the incision (cm)
19.3 ± 5.8
30.4 ± 5.9
0.000
Operative time (min)
194.0 ± 33.0
182.0 ± 42.0
0.407
Deformities (n)
LLD
1
0
0.277
Angulation
Rotation
4
2
0.272