Skip to main content

Table 4 The von Mises stress and displacement of pelvis

From: Comparison of reconstruction plate screw fixation and percutaneous cannulated screw fixation in treatment of Tile B1 type pubic symphysis diastasis: a finite element analysis and 10-year clinical experience

  Anterior ring Posterior ring
RPSF PCSF (RPSF − PCSF)/RPSF RPSF PCSF (RPSF − PCSF)/RPSF
The von Mises stress (MPa) [0.212–1.132] [0.336–1.004] −58.49~11.31 % [0.801–3.122] [0.787–1.989] 17.48~36.29 %
The displacement (mm) [0.051–0.201] [0.047–0.059] 7.84~70.65 % [0.031–0.153] [0.056–0.097] −80.6~36.6 %
  1. PCSF percutaneous cannulated screw fixation, RPSF reconstruction plate screw fixation