From: Clinical outcomes of locked plating of distal femoral fractures in a retrospective cohort
Result | Criteria |
---|---|
Excellent | Full extension; flexion >110°; no deformity or joint incongruity |
Good | Full extension; flexion >90°; <5° of varus or valgus; loss of length <1.5 cm, minimal pain |
Fair | Flexion of 75°–90°; varus, valgus, or angular deformity of 5°–10°; mild or moderate pain |
Poor | Flexion <75°; valgus, varus, or angular deformity >10°; articulate incongruity; frequent pain requiring analgesics |