Skip to main content

Table 2 Procedure, used osteosynthesis implants and articular displacement comparing pre- to postoperative CT

From: An interactive surgical planning tool for acetabular fractures: initial results

Case

Surgical approach

Fixation

Articular dis-placement (mm)

1

Stoppa, first window of ilioinguinal approach

prebent 14-hole and 5-hole plates

3

2

Ilioinguinal approach

prebent 9-hole plate, 7.3 mm lag screw (acetabular dome)

1

3

Stoppa, first window of ilioinguinal approach

prebent 12-hole plate, two 7.3 mm lag screws (posterior column)

1

4

Stoppa, first window of ilioinguinal approach

prebent 12-hole plate, 7.3 mm lag screw (acetabular dome)

1

5

Stoppa, additional posterior approach

prebent 9-hole and 7-hole plates, additional 5-hole plate

3

6

Stoppa, first window of ilioinguinal approach

prebent 12-hole and 9-hole plates

2

7

Stoppa, first window of ilioinguinal approach

prebent 12-hole and 9-hole plates

2