From: Finite element analysis of titanium anatomic plate and titanium reconstructive plate for treatment of extra-articular fractures of the scapula
Materials
Elastic modulus (MPa)
Poisson ratio
Cortical bone
17,000
0.30
Cancellous bone
1600
Plate
114,000
Screw