Skip to main content

Table 1 The stiffness of the springs used in this study

From: Biomechanical comparison of different screw-included angles in crossing screw fixation for transverse patellar fracture in level walking: a quasi-dynamic finite element study

 

Stiffness of single spring (N/mm)

Spring Numbers

References

Patellar ligament

24

44

[26]

Medial collateral ligament

25

3

[25]

Lateral collateral ligament

24

3

[25]

Anterior cruciate ligament

120

2

[24]

Posterior cruciate ligament

120

2

[23]