Table 7 Comparison of safety range between male and female (Mean ± SD, n = 100)

From: The placement of percutaneous retrograde acetabular posterior column screw based on imaging anatomical study of acetabular posterior column corridor

 

Lateral inclination angle (°)

Anterior inclination angle (°)

Min

Max

Max–Min

Min

Max

Max–Min

Male

7.34 ± 3.33

15.94 ± 3.39

8.59 ± 0.23

9.85 ± 4.63

21.25 ± 5.49

11.40 ± 0.25

Female

4.86 ± 2.77

13.33 ± 3.04

8.47 ± 0.23

8.07 ± 5.03

19.02 ± 5.71

10.94 ± 0.31