Skip to main content

Table 2 Comparison of acetabular cup positioning between R-THA and M-THA

From: Robotic-assisted versus manual total hip arthroplasty in obese patients: a retrospective case–control study

 

R-THA

M-THA

P value

Inclination (°)

41.29 ± 3.04

40.48 ± 4.81

0.27

Anteversion (°)

20.71 ± 1.98

19.08 ± 4.04

0.005

HCOR-d (mm)

1.6 ± 1.3

2.6 ± 1.7

 < 0.001

VCOR-d (mm)

1.9 ± 1

3.1 ± 1.1

 < 0.001

LLD (mm)

2.9 ± 1.6

7.3 ± 2.6

 < 0.001

LLD ≤ 10(mm)

52/52 (100%)

56/64 (87.5%)

0.008

Postoperative HHS

91.10 ± 4.05

90.39 ± 4.86

0.404

Postoperative FJS

81.40 ± 9.34

80.05 ± 11.65

0.497

  1. LLD leg length discrepancy, HCOR-d the horizontal center of rotation discrepancy, VCOR-d the vertical center of rotation, HHS Harris Hip Score, FJS Forgotten Joint Score