Skip to main content

Table 1 Loop circumference in millimeters of static surgeon’s knot tied with various sutures types after a 50 N tension load with different constructs (Group A: non-post limb cut at 1 mm; Group B: non-post limb cut at 4 mm; Group C: post limb cut at 1 mm; Group D: non-post limb cut at 4 mm)

From: A biomechanical study of the medial row tightening on stability of single stitch suture-bridge construct

Group

Ethibond 2

Hi-Fi

Sutblue

Hi-Fi Ribbon

SingleFlat 2

p value

A

33 [33;34.5]

32 [32;32.75]

30 [30;30.75]

31 [31;32.5]

30 [29.25;30]

 < 0.01

B

33 [33;33]

32 [30.88;32.75]

31 [30.25;31]

31 [31;31.75]

30 [29.25;30]

 < 0.01

C

33 [33;33]

32.5 [32;33.75]

30 [30;30]

31 [31;31]

29 [28;30]

 < 0.01

D

33 [33;33]

32.5 [32;33.75]

30 [30;30]

31 [31;31]

29 [28;30]

 < 0.01