Skip to main content

Table 2 Comparisons of clinical and radiographic outcomes at the last visit between both groups

From: Cannulated compression screw with versus without two K-wire fixation for treatment of scaphoid waist fracture nonunion

Variable

Tripod fixation group (n = 45)

Single cannulated screw fixation group (n = 58)

p

Union rate

45/45 (100%)

55/58 (94.8%)

0.122

Time to union

14.8 ± 3.8

17.6 ± 3.6

0.027*

Pain assessment on VAS (0–10)

1.4 ± 1.7

1.6 ± 2.0

0.203

ROM % of healthy side

92.3 ± 7.6

93.7 ± 7.4

0.483

Grip strength % of healthy side

94.7 ± 4.5

94.1 ± 5.2

0.923

Quick DASH score (0–100)

19.3 ± 4.1

17.9 ± 5.2

0.317

Mayo score (0–100)

87.6 ± 10.6

86.4 ± 11.3

0.722

LISA

34.5° ± 12.1°

33.7 ± 14.2°

0.790

HLR

0.67 ± 0.08

0.63 ± 0.08

0.917

  1. VAS, visual analogue scale score; LISA, lateral intrascaphoid angle; HLR, height length ration; DASH, Disabilities of the Arm, Shoulder, and Hand
  2. *Statistically signiant