Skip to main content

Table 4 Incidence of complications between two groups

From: Application of a new integrated low-profile anterior plate and cage system in single-level cervical spondylosis: a preliminary retrospective study

Ā 

Carmen group

Zero-P group

P value

Dysphagia

1 (3.6)

2 (3.0)

0.872

ASD (n, %)

2 (7.1)

5 (7.4)

0.971

Axial pain (n, %)

0 (0)

2 (3.0)

0.359

Pseudoarthrosis

0 (0)

1 (1.5)

0.519

Implant failure

0 (0)

0 (0)

ā€“

Revisions

0 (0)

0 (0)

ā€“

  1. ASD, adjacent segment degeneration. A P value of less than 0.05 was considered to indicate a statistically significant difference