Skip to main content

Table 4 Maximal von Mises stresses of comminuted fracture of the distal humerus models under different testing conditions

From: Biomechanical properties of a novel fixation system for intra-articular distal humerus fractures: a finite element analysis

Configuration

Part

Axial (MPa)

Bending (MPa)

Rotational torsion (MPa)

Novel plating

Bone

12.74

5.93

102.60

Plate and screw

85.99

28.62

334.70

Orthogonal plating

Bone

42.66

6.08

60.26

Plate and screw

147.40

44.39

211.10

Orthogonal plating with lag screws

Bone

36.73

6.87

53.49

Plate and screw

116.0

44.38

211.40