Skip to main content

Table 3 Comparison between CoC and polyethylene

From: Ten-year survival of ceramic-on-ceramic total hip arthroplasty in patients younger than 60 years: a systematic review and meta-analysis

Hips no

Revision

Aseptic loosening

Component fracture

Survival analysis (%)

Atrey 2018

    

 *CoC (29)

1

0

1

89

 **CoP (28)

5

4

0

85

Beaupre

    

 CoC (48)

0

0

0

94

 CoP (44)

3

0

0

90

D'Antonio

    

 CoC (184)

6

0

1

99.3

 ***MoP (95)

10

3

0

98.9

  1. *CoC: Ceramic-on-ceramic
  2. **CoP: Ceramic-on-polyethylene
  3. ***MoP: Metal-on-polyethylene