Skip to main content

Table 3 Diagnostic performance of biomarkers in combination

From: Plasma levels of D-dimer and fibrin degradation product are unreliable for diagnosing periprosthetic joint infection in patients undergoing re-revision arthroplasty

Combination

AUC (95% CI)

Youden index

Sensitivity (%)

Specificity (%)

PPV (%)

NPV (%)

Combination of two markers

      

CRP + ESR

0.867 (0.779–0.956)

0.630

82.4

80.6

82.3

80.7

CRP + IL-6

0.877 (0.769–0.984)

0.700

91.7

78.3

81.5

90.0

ESR + IL-6

0.893 (0.805–0.981)

0.658

87.5

78.3

80.8

85.75

Combination of three markers

      

CRP + ESR + IL-6

0.897 (0.811–0.982)

0.656

91.7

73.9

78.6

89.5

  1. AUC, area under the receiver operating characteristic curve; CI, confidence interval; CRP, C-reactive protein; ESR, erythrocyte sedimentation rate; IL-6, interleukin-6; PPV, positive predictive value; NPV, negative predictive value