Skip to main content

Table 2 Diagnostic performance of biomarkers individually

From: Plasma levels of D-dimer and fibrin degradation product are unreliable for diagnosing periprosthetic joint infection in patients undergoing re-revision arthroplasty

Biomarker

AUC (95% CI)

Youden index

Cut-off

Sensitivity (%)

Specificity (%)

PPV (%)

NPV (%)

CRP (mg/L)

–

0.598

10.00*

82.4

77.4

80.0

80.0

0.845 (0.744–0.947)

0.656

8.40#

88.2

77.4

81.1

85.7

ESR (mm/h)

–

0.501

30.00*

82.4

67.7

73.7

77.8

0.820 (0.715–0.925)

0.566

33.00#

82.4

74.2

77.8

79.4

D-dimer (mg/L)

0.595 (0.429–0.860)

0.335

0.80

85.7

47.8

66.7

73.3

FDP (mg/L)

0.550 (0.366–0.733)

0.094

2.80

56.5

52.9

61.9

47.3

IL-6 (pg/L)

0.839 (0.724–0.953)

0.529

6.00

83.3

69.6

74.1

80.0

  1. AUC, area under the receiver operating characteristic curve; CI, confidence interval; CRP, C-reactive protein; ESR, erythrocyte sedimentation rate; FDP, fibrin degradation product; IL-6, interleukin-6; PPV, positive predictive value; NPV, negative predictive value
  2. *From the 2013 International Consensus Meeting Criteria on PJI [23]
  3. #Based on the Youden index for our cohort