Table 2 Postoperative knee flexion and ROM difference between the injured knee and the contralateral side

From: Abstaining from symptomatic implants of modified tension band wiring by nonabsorbable suture fixation for transverse patella fractures

Postoperative knee flexion

Follow-up period

Degree of flexion

Mean difference

p-value*

(mean ± SD)

(95% CI)

 3 months

96.88 ± 24.01

  

 6 months

116.25 ± 21.25

19.38 (13.23–25.52)

<0.001*

 12 months

120.00 ± 18.62

23.13 (16.39–29.86)

<0.001*

Repeated measures analysis of variance

<0.001**

ROM difference

Follow-up period

ROM difference

Mean difference

p-value*

(mean ± SD)

(95% CI)

 3 months

−30.31 ± 15.33

  

 6 months

−12.19 ± 12.38

−18.13 (−23.53, −12.72)

<0.001*

 12 months

−8.44 ± 10.91

−21.88 (−28.17, −15.58)

<0.001*

Repeated measures analysis of variance

<0.001**

  1. SD standard deviation, CI confidence interval
  2. *Paired t test comparison with baseline (3 months)