Skip to main content

Table 4 Shifts in the gap of pubis ruptures in the sitting posture (X ± S, n = 4, mm)

From: Biomechanical study of Tile C3 pelvic fracture fixation using an anterior internal system combined with sacroiliac screws

Loads (N)

Group A

Group B

Group C

Group D

Left

Right

Left

Right

Left

Right

Left

Right

200

0.3675±0.00957

0.3675±0.00500

0.3450±0.01000

0.3525±0.00500

0.3400±0.00816

0.3375±0.01258

0.3350±0.00577

0.3350±0.00577

400

0.5450±0.00577

0.5450±0.00577

0.4900±0.00816

0.4900±0.00816

0.4600±0.00816

0.4600±0.00816

0.4650±0.01291

0.4650±0.00577

600

0.7725±0.00500

0.7550±0.03697

0.7400±0.00816

0.7450±0.01291

0.7150±0.00577

0.7075±0.00500

0.7100±0.01414

0.7125±0.00957

  1. Every two groups were compared by the independent t-test, P > 0.05