Skip to main content

Table 4 Shifts in the gap of pubis ruptures in the sitting posture (X ± S, n = 4, mm)

From: Biomechanical study of Tile C3 pelvic fracture fixation using an anterior internal system combined with sacroiliac screws

Loads (N) Group A Group B Group C Group D
Left Right Left Right Left Right Left Right
200 0.3675±0.00957 0.3675±0.00500 0.3450±0.01000 0.3525±0.00500 0.3400±0.00816 0.3375±0.01258 0.3350±0.00577 0.3350±0.00577
400 0.5450±0.00577 0.5450±0.00577 0.4900±0.00816 0.4900±0.00816 0.4600±0.00816 0.4600±0.00816 0.4650±0.01291 0.4650±0.00577
600 0.7725±0.00500 0.7550±0.03697 0.7400±0.00816 0.7450±0.01291 0.7150±0.00577 0.7075±0.00500 0.7100±0.01414 0.7125±0.00957
  1. Every two groups were compared by the independent t-test, P > 0.05
\