Skip to main content

Table 2 Differences in time to complete the five times sit-to-stand test and perceived pain when performing the test among individuals with hip osteoarthritis prior to surgery, 1 year after total hip arthroplasty, and a healthy control group

From: Functional movement compensations persist in individuals with hip osteoarthritis performing the five times sit-to-stand test 1 year after total hip arthroplasty

 

Hip OA pre THA (n = 28)

Hip OA post THA (n = 28)

Control group (n = 21)

∆ Pre THA vs. control

∆ Post THA vs. control

∆ Pre THA vs. post THA

    

p

95% CI

p

95% CI

p

95% CI

Time, seconds, mean (SD)

15.1 (4.2)

11.5 (2.9)

10.1 (3.0)

5.0

< 0.001

[2.8, 7.1]

1.4

0.119

[− 0.4, 3.1]

3.6

< 0.001

[1.8, 5.4]

VAS pain, 0–100, median (range)

21 (0–81)

0 (0–35)

  

  

21

< 0.001

[− 4.9, − 1.6]

  1. OA osteoarthritis, SD standard deviation, THA total hip arthroplasty, VAS visual analog scale