Skip to main content

Table 4 The sensitivity of the elements

From: Topping-off surgery vs posterior lumbar interbody fusion for degenerative lumbar disease: a finite element analysis

Mesh

Nodes

Element

Approximate computational time (min)

Max model displacement (mm)

Adjacent disc von Mises (MPa)

Coarse

125970

84676

8

4.3151

1.734

Medium

181156

123871

15

4.0609

1.455

Fine

537548

375680

40

3.8904

1.8582

Very fine

942449

675635

180

3.8736

1.8219

Optimize

201654

136934

25

3.9507

1.8162