From: Initial stability and stress distribution of ankle arthroscopic arthrodesis with three kinds of 2-screw configuration fixation: a finite element analysis
Configuration
Part
Maximum contact pressure
Average contact pressure
Group A
Tibia
213.63
9.18
Talus
272.09
7.06
Group B
144.32
8.92
173.45
6.78
Group C
242.53
9.03
393.46
6.83