Skip to main content

Table 1 Patient characteristics

From: Minimally invasive treatment for anterior pelvic ring injuries with modified pedicle screw-rod fixation: a retrospective study

Patient

Age (years)

Sex

Tile type

Surgical procedures (anterior + posterior fixation)

Implant site of anterior ring

Time from injury to surgery (days)

Operation time (min)

Blood loss (mL)

Injury mechanism

Matta criteria

Complications

1

39

F

B2

MPSRF + PIS + SPF

U

14

151

200

Fall

Excellent

 

2

44

F

B3

MPSRF + SPF

B

8

312

600

Fall

Good

 

3

28

F

B2

MPSRF + PTP

U

8

194

100

Fall

Excellent

 

4

37

F

C2

MPSRF + PTP + SPF

B

8

292

350

Fall

Excellent

 

5

36

M

C2

MPSRF + PIS + SPF

U

2

183

160

Crush

Excellent

Rod breakage

6

42

M

B3

MPSRF

B

1

283

700

Traffic

Excellent

 
  1. Patient data as abbreviated terms, F female, M male, MPSRF modified pedicle screw-rod fixation, PIS percutaneous iliosacral screw, PTP percutaneous transiliac plate, SPF spinal pelvic fixation, U unilateral, B bilateral