Table 4 Comparison of the ARFI values of healthy and repaired tendons by Wilcoxon signed-rank test

From: Does elasticity of Achilles tendon change after suture applications? Evaluation of repair area by acoustic radiation force impulse elastography

Measurement

N

SWV ± SD (m/s)

p value

Repaired P

18

6.37 ± 0.70

0.01*

Healthy P

18

3.93 ± 0.81

Repaired N

18

7.31 ± 0.65

0.01*

Healthy N

18

5.64 ± 0.89

Repaired D 15°

18

8.32 ± 0.49

0.01*

Healthy D 15°

18

7.35 ± 0.70

Repaired D 30°

18

9.28 ± 0.35

0.01*

Healthy D 30°

18

8.48 ± 0.54

  1. Repaired tendons had significantly higher values compared to the healthy tendons, indicating less elasticity in the repaired tendons
  2. SWV shear wave velocity, P plantar flexion, N neutral, D dorsiflexion