Skip to main content

Table 2 Clinical outcomes of 36 patients with fresh type II odontoid fracture who underwent ACSF or PIWF

From: The comparison of clinical outcome of fresh type II odontoid fracture treatment between anterior cannulated screws fixation and posterior instrumentation of C1-2 without fusion: a retrospective cohort study

Parameter

ACSF (n = 11)

PIWF (n = 25)

p

Average operation time (minutes)

121

173

0.007

Average blood loss (ml)

33

148

0.002

Complication, n(%)

0(0)

0(0)

 

Average NDI (%)

 1 year after first operation

5

13

0.000

 1 year after second operation

4

8

0.009

Average range of rotatory motion (°)

 1 year after first operation

89(83,93)

46(35,58)

0.000

 1 year after second operation

88(81,95)

83(79,87)

0.148

Union rate (%)

90.9

96