Criteria | Non-anatomical | Poor internal fixation |
---|---|---|
1 | Diastasis between the base of the first and second metatarsals >2 mm | Placement of implantation is inappropriate |
2 | Angulation of the first metatarsal with the talus > 15° | Exposed part of the screw is >30% |