Skip to main content
  • Research article
  • Open access
  • Published:

Efficacy and safety of tension band wiring versus plate fixation in olecranon fractures: a systematic review and meta-analysis

Abstract

Background

Olecranon fracture (OF) is a common upper limb fracture, and the most commonly used techniques are still tension band wiring (TBW) and plate fixation (PF). The aim of the current study is to discuss whether TBW or PF technique of internal fixation is better in the treatment of OFs, using the method of meta-analysis.

Methods

The eligible studies were acquired from PubMed, CNKI, Embase, Cochrane Library, and other sources. The data were extracted by two of the coauthors independently and were analyzed by RevMan5.3. Standardized mean differences (SMDs), odds ratios (ORs), and 95% confidence intervals (CIs) were calculated. Cochrane Collaboration’s Risk of Bias Tool and Newcastle–Ottawa Scale were used to assess risk of bias.

Results

Thirteen studies including 1 RCT and 12 observational studies were assessed. Our meta-analysis results showed that both in RCT and observational studies, there were no significant differences between the two groups in disabilities of the arm, shoulder and hand (DASH) (SMD = 0.07, 95% CI = −0.32 to 0.46, p = 0.73), improvement rate (OR = 0.76, 95% CI = 0.48–1.22, p = 0.26), range of motion (ROM), operation time (SMD = −0.51, 95% CI = −1.17 to 0.14, p = 0.12) and blood loss (SMD = −0.97, 95% CI = −2.06 to 0.11, p = 0.08). The overall estimate of complications indicated that the pooled OR was 2.61 (95% CI = 1.65–4.14, p < 0.0001), suggesting that the difference was statistically significant. We also compared the outcomes of patients with mayo type IIA OFs treated by TBW and PF in DASH and ROM and found no differences.

Conclusions

Both TBW and PF interventions had treatment benefit in OFs. The current study reveals that there are no significant differences in DASH, improvement rate, ROM, operation time, and blood loss between TBW and PF for OFs. Due to the less complications, we recommend the PF approach as the optical choice for OFs. More high-quality studies are required to further confirm our results.

Background

Olecranon is an important part of the elbow joint and associated with elbow instability. Olecranon fracture (OF) affecting adults of both sexes is a common upper limb fracture caused by violent injury and accounts for about 10% of the fractures around the elbow [1]. Except low-grade avulsion fractures or surgery contraindications, most OFs involve the articular surface of the elbow joint, and uneven articular surface can cause limited activity, delayed recovery, traumatic arthritis, and other complications. So, accurate reduction and rigid fixation are effective measures to prevent joint instability and occurrence of osteoarthritis [2, 3].

Manipulative reduction and external fixation apply to the patients with non-displaced or displaced OFs, but the majority of patients with OFs need internal fixations. There are many methods of internal fixations for the treatment of OFs, such as figure of 8 steel wire fixation, K-wire tension band, anatomical plate, 1/3 tube type plate, hollow nail plus tension, and memory alloy, but the most commonly used techniques are still tension band wiring (TBW) and plate fixation (PF) [4, 5]. Especially for mayo type IIA OFs, which is the most common type, both of them have comparable efficacy. Some researches believe that PF is a good alternative as complications are minimal [6, 7]. However, there is still a controversy about the superiority between TBW and PF approach adopted for OFs [8, 9].

We firstly compared the efficacy and safety of TBW versus PF in OFs, and the aim of the current study is to discuss whether TBW or PF technique of internal fixation is better in the treatment of OFs, using the method of meta-analysis with strict inclusion/exclusion criteria.

Methods

Search strategy

Four databases (PubMed, CNKI, Embase, and Cochrane Library) were searched using the keywords such as “olecranon fracture,” “clinical trials,” “tension band wiring or K-wire tension band,” “plate fixation or plate,” and “locking plate or locking compression plate” through March 2016 to collect relevant studies about the clinical comparison of TBW and PF in OFs. The titles and abstracts of potential related articles identified by the electronic search were reviewed.

Inclusion and exclusion criteria

We considered all published and unpublished studies covering randomized controlled trials (RCTs) and observational studies including retrospective and prospective studies. All patients in such researches must be diagnosed as olecranon fractures according to imaging examinations and symptoms and must accept surgical treatment. Classification criterion of fracture, gender, and age were ignored. The references of the included articles were searched for avoiding omission of potentially related studies.

Study quality appraisal

The quality of the included trials was assessed independently by two authors (BYF and WL) using a blinding method (without revealing the names of assigned studies). Cochrane Collaboration’s Risk of Bias Tool was conducted for the appraisal of each RCT study quality. This risk of bias tool incorporates the assessment of randomization (sequence generation and allocation concealment), blinding (participants and outcome assessors), incomplete outcome data, selective outcome reporting, and other risks of bias. The items were judged as “low risk,” “unclear risk,” or “high risk.” Observational studies were assessed with Newcastle–Ottawa Scale including eight items. A higher overall score indicates a lower risk of bias and a score of 5 or less (out of 9) corresponds to a high risk of bias. All disagreement would be reappraised by a third author (ZJW), and a consensus must be reached by discussion. The RevMan software (version 5.3) was used for the analysis of risk of bias and pooling the results.

Data extraction

Two partners (BYF and WL) independently assessed the titles and abstracts of all studies screened during initial search and excluded any clearly irrelevant studies using the inclusion criteria. Data were independently extracted using a standard data form for the first author’s name, year of publication, sample size, gender, age, intervention, country, study design, follow-up, and relevant outcome. The relevant outcomes of the selected trials included the following: (1) the primary outcomes of this study were the functional outcomes, assessed by the disabilities of the arm, shoulder and hand (DASH), as well as improvement rate; (2) secondary outcome measures included the analysis of passive range of motion (ROM), comprising flexion and extension of the elbow, pronation and supination of the forearm, operation time, and blood loss; and (3) complications.

Statistical analysis

A meta-analysis was conducted using RevMan statistical software, version 5.3 (Cochrane Collaboration, http://tech.cochrane.org/revman/download). For dichotomous outcomes, odds ratios (ORs) and 95% confidence intervals (CIs) were calculated, while standardized mean differences (SMDs) and 95% CIs were used for continuous outcomes. SMD was conducted over weighted mean difference because different measurement indexes that adopted different tools were used in these studies. Heterogeneity among the studies was assessed by Cochrane Handbook Q test and I 2 statistic. A p < 0.05 and I 2 > 50% were considered significant heterogeneity, and random effect models were applied. Otherwise, fixed effect models were used if there was no significant heterogeneity (p ≥ 0.05, I 2 ≤ 50%). The publication bias was showed by a funnel plot.

Results

Description of included studies

The literature search and selection process in the present study are shown in the PRISMA flow diagram (Fig. 1). Searches conducted in the PubMed, CNKI, Embase, Cochrane Library databases, and other sources yielded a total of 1161 articles. After removing duplicates, 221 literatures were remained. Based on the titles and abstracts review, 196 irrelevant articles and 2 systematic review of them were excluded. Twenty-three full-text articles were assessed for eligibility. However, ten articles were excluded based on the previously established exclusion criteria (six different operation methods, three biomechanical studies, and one study without data). Finally, 13 trials (1 RCT and 12 observational studies) [1022] were included in this systematic review and meta-analysis. The detailed information of included studies is shown in Table 1.

Fig. 1
figure 1

PRISMA flow diagram

Table 1 Characteristics of studies included

Risk of bias in included studies

Methodological quality assessment of the 13 included studies [1022] is presented in Fig. 2 and Table 2. Of the RCT, the Hume study [13] showed unclear information about the random sequence generation, blinding and allocation concealment, so we considered it a low-quality study. Among observational studies, scores of all 12 studies [1012, 1422] on the Newcastle–Ottawa Scale assessing risk of bias ranged from 7 to 9, indicating a low risk of bias.

Fig. 2
figure 2

Risk of bias summary revealing the review of the authors’ judgments about each risk of bias item for each included study. Plus sign represents risk of bias present, minus sign represents risk of bias absent, and question mark sign represents risk of bias uncertain

Table 2 Risk of bias assessment of observational studies

Disabilities of the arm, shoulder and hand

Two included studies [10, 11] provided the data in terms of the DASH. The pooled results of the DASH revealed no difference between TBW and PF (SMD = 0.07, 95% CI = −0.32 to 0.46, p = 0.73) (Fig. 3). The heterogeneity was none (I 2 = 0%, p = 0.56).

Fig. 3
figure 3

Forest plot of analysis showing the DASH between TBW and PF

Improvement rate

The improvement rate of treated patients was acquired from 12 included studies [10, 1222] consisting of 635 OF patients. Although the pooled results exhibited no statistically significant difference between TBW and PF (OR = 0.76, 95% CI = 0.48–1.22, p = 0.26) (Fig. 4), the heterogeneity was low in included trials (I 2 = 13%, p = 0.32).

Fig. 4
figure 4

Forest plot of analysis showing the improvement rate between TBW and PF

Range of motion

Analysis of passive range of motion (ROM) comprised flexion and extension of the elbow and pronation and supination of the forearm measured with a goniometer and evaluated with respect to the arc of movement of the uninjured arm.

Flexion of the elbow

The flexion of the elbow was recorded by three included researches [10, 11, 17]. Figure 5 showed that the flexion of the elbow did not have a significant difference between TBW and PF (SMD = −0.06, 95% CI = −0.52 to 0.39, p = 0.78). The random effect models were used, and there was moderate heterogeneity in the pooled results (I 2 = 57%, p = 0.10).

Fig. 5
figure 5

Forest plot of analysis showing the flexion of the elbow between TBW and PF

Extension of the elbow

The extension of the elbow was reported in 3 studies [10, 11, 17] with 204 patients. There was no significant difference in extension of the elbow between the two groups (SMD = −0.20, 95% CI = −0.47 to 0.08, p = 0.17) in Fig. 6. No heterogeneity was found among the studies (p = 0.99, I 2 = 0%), so we used the fixed effect models.

Fig. 6
figure 6

Forest plot of analysis showing the extension of the elbow between TBW and PF

Pronation of the forearm

The pronation of the forearm of treated patients was acquired from three included studies [10, 11, 17]. Although the pooled results exhibited no statistically significant difference between TBW and PF (SMD = 0.20, 95% CI = −0.08 to 0.47, p = 0.16) (Fig. 7), the heterogeneity was none in included trials (I 2 = 0 %, p = 0.61).

Fig. 7
figure 7

Forest plot of analysis showing the pronation of the forearm between TBW and PF

Supination of the forearm

Three included studies [10, 11, 17] provided the data in terms of the supination of the forearm. The pooled results of the supination of the forearm revealed no difference between TBW and PF (SMD = 0.11, 95% CI = −0.17 to 0.39, p = 0.43) (Fig. 8). The heterogeneity was none (I 2 = 0%, p = 0.60).

Fig. 8
figure 8

Forest plot of analysis showing the supination of the forearm between TBW and PF

Outcomes of patients with mayo type IIA OFs

We also compared the outcomes of patients with mayo type IIA OFs treated by TBW and PF. The two included studies [10, 11] provided the data in terms of the DASH and ROM. The pooled results of the DASH revealed no difference between TBW and PF (SMD = 0.21, 95% CI = −0.33 to 0.75, p = 0.45) (Fig. 9). The heterogeneity was low (I 2 = 32%, p = 0.23).

Fig. 9
figure 9

Forest plot of analysis showing the DASH of patients with mayo type IIA OFs between TBW and PF

Figure 10 showed that the flexion of the elbow did not have a significant difference between TBW and PF (SMD = −0.23, 95% CI = −0.77 to 0.31, p = 0.41). There was no heterogeneity in the pooled result (I 2 = 0%, p = 0.40).

Fig. 10
figure 10

Forest plot of analysis showing the flexion of the elbow of patients with mayo type IIA OFs between TBW and PF

There was no significant difference in extension of the elbow between the two groups (SMD = 0.16, 95% CI = −0.38 to 0.70, p = 0.57) in Fig. 11. Low heterogeneity was found among the studies (p = 0.19, I 2 = 42%), so we used the fixed effect models.

Fig. 11
figure 11

Forest plot of analysis showing the extension of the elbow of patients with mayo type IIA OFs between TBW and PF

The pooled results of the pronation of the forearm exhibited no statistically significant difference between TBW and PF (SMD = −0.06, 95% CI = −0.60 to 0.47, p = 0.82) (Fig. 12), and the heterogeneity was none in included trials (I 2 = 0%, p = 0.89).

Fig. 12
figure 12

Forest plot of analysis showing the pronation of the forearm of patients with mayo type IIA OFs between TBW and PF

The pooled results of the supination of the forearm revealed no difference between TBW and PF (SMD = −0.02, 95% CI = −0.56 to 0.52, p = 0.94) (Fig. 13). No heterogeneity was found (I 2 = 0%, p = 0.41).

Fig. 13
figure 13

Forest plot of analysis showing the supination of the forearm of patients with mayo type IIA OFs between TBW and PF

Operation time and blood loss

The operation time of treated patients was acquired from two included studies [17, 22]. Although the pooled results exhibited no statistically significant difference between TBW and PF (SMD = −0.51, 95% CI = −1.17 to 0.14, p = 0.12) (Fig. 14), the heterogeneity was moderate in included trials (I 2 = 66%, p = 0.09).

Fig. 14
figure 14

Forest plot of analysis showing the operation time between TBW and PF

The blood loss was recorded by two included researches [17, 22]. Figure 15 showed that the blood loss did not have a significant difference between TBW and PF (SMD = −0.97, 95% CI = −2.06 to 0.11, p = 0.08). There was high heterogeneity in the pooled results (I 2 = 86%, p = 0.08).

Fig. 15
figure 15

Forest plot of analysis showing the blood loss between TBW and PF

Complications

In Fig. 16, 11 included studies [1015, 1719, 21, 22] consisting of 614 OF patients reported complications after treatment. Moderate heterogeneity among studies (p = 0.05, I 2 = 45%) was found, so we used the fixed effect model. The overall estimate indicated that the pooled OR was 2.61 (95% CI = 1.65–4.14, p < 0.0001), suggesting that the difference was statistically significant.

Fig. 16
figure 16

Forest plot of analysis showing the complications between TBW and PF

Publication bias

A funnel plot of 12 included studies [10, 1222] is shown in Fig. 17. The points in the funnel plot were almost symmetrically distributed, indicating that the publication bias was not apparent.

Fig. 17
figure 17

A funnel plot for publication bias

Discussion

In this study, we identified 1 RCT and 12 observational studies for investigating the efficacy and safety of TBW versus PF intervention. Our meta-analysis results showed that both in RCT and observational studies, there were no significant differences between the two groups in DASH, improvement rate, and ROM; therefore, both groups had equal efficacy.

The TBW technology is widely used in OFs and is considered as the gold standard for the treatment of OFs [23]. The technical advantage of TBW is that tension band fixation can neutralize tension at the fracture site and change it into compressive stress, which make the fracture site more closely and better promote fracture healing [24]. What is more, without extensive stripping of surrounding tissues at the fracture site, TBW approach contributes to less damage [25]. The main shortcoming of this method is soft tissue stimulation of Kirschner wires and Kirschner wires are easy to slide out, resulting in failure of fixation [26]. However, the TBW method is not very suitable for all types of OFs. It is considered that the TBW is still the gold standard for the treatment of the simplest displaced fractures, but for oblique fractures, OFs involving the coronoid process, dislocation, and comminuted fractures such as mayo IIB or mayo III fractures, the fixation of TBW is not strong enough and reliable [24, 27]. Both of TBW and PF had comparable efficacy for mayo type IIA OFs, so according to the pooled results of this study, we found that there really were no significant differences between the two groups in DASH and ROM for the patients with mayo type IIA OFs.

The PF method can overcome the main shortcoming of TBW, and especially comminuted fractures can be fixed firmly by PF. The PF is consistent with the shape of proximal ulna, meets the design of olecranon anatomy, and is closer to bone surface, which can make the fixation more stable and reliable [28, 29]. Nevertheless, the PF approach has some disadvantages. With large wounds and soft tissue injury of the elbow joint, the triceps and their attachment points of olecranon are damaged when fractures are fixed. The side of the plate may have the stress shielding, which can lead to the thinning of bone cortex and reduction of bone strength in the side of the plate [30, 31].

The complications in 11 included studies [1015, 1719, 21, 22] also should be discussed. The meta-analysis results of complications showed that there was a significant difference between the two groups. In Benedikt’s study [10], implant irritation (with subsequent removal) was the most common complication (7 in locking compression plate (LCP) groups, and 12 in TBW groups). The other complications such as infection, hardware failure, and k-wire migration were rare. In Gagan’s study [12], six patients had symptomatic metal skin impingement, three patients had superficial infection, and two patients had implant loosening (plate loosening/proximal migration). Deep infection and delayed union were reported to be rare complications. In Luigi’s study [11], four patients in each group were related with pain and three patients in each group were attacked by non-union. Four patients in TBW groups had proximal K-wire migration. Ulnar neuropathy, radio-ulnar synostosis, and skin breakdown were rarely reported in patients. In addition, they also found a significant lower rate of hardware removal in PF groups. In Hume’s study [13], patients were more likely to develop symptomatic metal prominence after TBW than after PF (TBW, 42%; PF, 5%). Two patients developed infections after TBW, which led to delayed or non-union. The other included studies [1422] reported almost same complications as mentioned above. In conclusion, according to the pooled results, the complications of patients received PF were less than that of TBW; therefore, the PF groups had better safety.

For operative time and blood loss, our pooled results exhibited no statistically significant difference between TBW and PF, but pooled block tended to PF if ignoring the heterogeneity. In Benedikt’s study [10], the average operative time in LCP groups (121 min) was almost twice as well as in TBW groups (88 min). The Hume study [13] also reported that the operative time required for TBW averaged 94.5 min, whereas that for PF groups averaged 120 min. Moreover, implant costs were significantly higher in PF groups in Benedikt’s study (approximately 300 € vs. 50 €) [10]. For union time in Gagan’s study [12], radiographic union occurred within 9 to 26 weeks of follow-up with no statistical difference in the average union time in TBW groups and PF groups at the final follow-up. With the application of new technology, we could conclude that the PF approach extended the operation time and blood loss and increased the costs.

Some limitations of this study should be noted. First, significant statistical heterogeneity of operation time and blood loss still existed among the included trials. Second, the RCT article included in this study primarily adopted random, controlled research, and design methods; however, in the random method, blinding and allocation concealment were not described in detail, which may result in high risks of selection biases. In addition, the included studies were mostly observational studies and not RCTs. They largely relied on retrospectively collected data, resulting in a high risk of selection bias. Finally, due to the small amount of trials comparing different approaches of OFs, additional randomized, controlled, multi-center, large-sample, high-quality trials are necessary in the future.

Conclusions

The current study using the method of meta-analysis reveals that there are no significant differences in DASH, improvement rate, ROM, operation time, and blood loss between TBW and PF for OFs. Due to the less complications, we recommend the PF approach as the optical choice for OFs.

Abbreviations

CIs:

Confidence intervals

DASH:

Disabilities of the arm, shoulder and hand

LCP:

Locking compression plate

OF:

Olecranon fracture

ORs:

Odds ratios

PF:

Plate fixation

RCTs:

Randomized controlled trials

ROM:

Range of motion

SMDs:

Standardized mean differences

TBW:

Tension band wiring

References

  1. Rommens PM, et al. Olecranon fractures in adults: factors influencing outcome. Inj-Int, J Care Inj. 2004;35(11):1149–57.

    Article  CAS  Google Scholar 

  2. Closkey RF, et al. The role of the coronoid process in elbow stability. J Bone Joint Surg Am. 2000;82(12):1749–53.

    Article  PubMed  Google Scholar 

  3. Amis AA, Miller JH. The mechanisms of elbow fractures: an investigation using impact tests in vitro. Inj-Int, J Care Inj. 1995;26(3):163–8.

    Article  CAS  Google Scholar 

  4. Baecher N, Edwards S. Olecranon fractures. J Hand Surg. 2013;38(3):593–604.

    Article  Google Scholar 

  5. Wilkerson JA, Rosenwasser MP. Surgical techniques of olecranon fractures. J Hand Surg. 2014;39(8):1606–14.

    Article  Google Scholar 

  6. Den HA, Heusinkveld M, Traa W, et al. Current techniques for management of transverse displaced olecranon fractures. Muscles. 2015;5(2):129–40.

    Google Scholar 

  7. Traa WA, Oomen PJA, Hamer AD, et al. Biomechanical studies on transverse olecranon and patellar fractures: a systematic review with the development of a new scoring method. Br Med Bull. 2013;108(1):131–57.

    Article  PubMed  Google Scholar 

  8. Duckworth AD, et al. The epidemiology of fractures of the proximal ulna. Inj-Int J Care Inj. 2012;43(3):343–6.

    Article  Google Scholar 

  9. Colton CL. Fractures of the olecranon in adults: classification and management. Inj-Int J Care Inj. 1973;5(2):121–ĩbr.

    Article  CAS  Google Scholar 

  10. Benedikt S, et al. Comparison of tension band wiring and precontoured locking compression plate fixation in mayo type IIA olecranon fractures. Acta Orthop Belg. 2014;80(1):106–11.

    Google Scholar 

  11. Tarallo L, et al. Simple and comminuted displaced olecranon fractures: a clinical comparison between tension band wiring and plate fixation techniques. J Endourol. 2014;134(8):1107–14.

    Google Scholar 

  12. Khann G, et al. A comparative study of tension band wiring and reconstruction plating in olecranon fractures. Pb Am J Orthop. 2012;8(1):57–61.

    Google Scholar 

  13. Hume MC, Wiss DA. Olecranon fractures. A clinical and radiographic comparison of tension band wiring and plate fixation. Clin Orthop Relat Res. 1992;8(28):229–35.

    Google Scholar 

  14. Chen YH, et al. Case control study on therapeutic effects of different fixation methods for the treatment of olecranon fracture. China J Orthop Trauma. 2014;27(11):891–5.

    Google Scholar 

  15. Lu JB, et al. The comparison of two internal fixations in treating olecranon fractures. Chin Clin Med. 2012;05(2):141–3.

    Google Scholar 

  16. Sui J, et al. Effect comparison of two kinds of therapeutic methods of olecranon fracture. China J Orthop Trauma. 2008;21(1):60–1.

    Google Scholar 

  17. Wang YA, et al. Effect analysis of Kirschner wire tension band and anatomical plate fixation for olecranon fracture. Chin J Bone Joint Injury. 2014;29(3):296–7.

    Google Scholar 

  18. Xu J, et al. Efficacy of tension band wiring and plate fixation in treatment of different types of olecranon fracture. Jiangsu Med. 2015;41(2):173–5.

    Google Scholar 

  19. Yu RH, et al. Effect observation of olecranon plate fixation and tension band wiring in treatment of olecranon fracture. Chin J Bone Joint Injury. 2011;26(9):839–40.

    Google Scholar 

  20. Zhang J, et al. Evaluation on the effect of olecranon hook plate and tension band wire in treatment of olecranon fracture. Orthop Biomech Mater Clin Study. 2005;2(2):37–8.

    Google Scholar 

  21. Zhang L, et al. Different methods of internal fixation in treatment of olecranon fracture. Int J Orthop. 2011;32(5):338–9.

    CAS  Google Scholar 

  22. Zhang XG, et al. The comparison of anatomical locking plate and tension band wiring in treating olecranon fractures. Chin J Bone Joint Injury. 2013;28(7):676–7.

    Google Scholar 

  23. Chalidis BE, et al. Is tension band wiring technique the “gold standard” for the treatment of olecranon fractures? A long term functional outcome study. J Orthop Surg Res. 2008;3(3):1–6.

    Google Scholar 

  24. Ikeda M, et al. Comminuted fractures of the olecranon. Management by bone graft from the iliac crest and multiple tension-band wiring. J Bone Joint Surg. 2001;83(6):805–8.

    Article  CAS  Google Scholar 

  25. Chen LJ, Zheng W, Yu W. Treatment of olecranon fracture using Kirschner with a hole in the tail and tensile band wire. Zhongguo Gu Shang/China J Orthop Trauma. 2003;16(3):167–8.

    Google Scholar 

  26. Romero JM, Miran A, Jensen CH. Complications and re-operation rate after tension-band wiring of olecranon fractures. J Orthop Sci. 2000;5(4):318–20.

    Article  CAS  PubMed  Google Scholar 

  27. Gordon MJ, et al. Comminuted olecranon fractures: a comparison of plating methods. J Shoulder Elb Surg. 2006;15(1):94–9.

    Article  Google Scholar 

  28. Mouhsine E, et al. Transolecranon anterior fracture dislocation. J Shoulder Elb Surg. 2007;16(3):352–7.

    Article  CAS  Google Scholar 

  29. Lalliss SJ, Branstetter JG. The use of three types of suture and stainless steel wire tension banding for the fixation of simulated olecranon fractures: a comparison study in cadaver elbows. J Bone Joint Surg (Br). 2010;92(2):315–9.

    Article  CAS  Google Scholar 

  30. Geert B, Peter K. Clinical evaluation of locking compression plate fixation for comminuted olecranon fractures. J Bone Joint Surg Am. 2009;91(10):2416–20.

    Article  Google Scholar 

  31. Wild JR, et al. Biomechanical evaluation of suture-augmented locking plate fixation for proximal third fractures of the olecranon. J Orthop Trauma. 2012;26(9):533–8.

Download references

Acknowledgements

Yi-Ming Ren wants to thank, in particular, the continued supports received from Jing-Ru Xue over 6 years. Will you marry me, Jing-Ru?

Funding

All authors are grateful for the support by the State Program of National Natural Science Foundation of China (81371957), the State Key Program of the National Natural Science Foundation of China (81330042), the Special Program for Sino-Russian Joint Research sponsored by the Ministry of Science and Technology, China (2014DFR31210), and the Key Program sponsored by the Tianjin Science and Technology Committee, China (13RCGFSY19000, 14ZCZDSY00044).

Availability of data and materials

As this paper is a meta-analysis, there are no patient data sets. The search strategy was for the study selection, which supports the conclusion of the meta-analysis.

Author’s contributions

YMR, HYQ, and ZJW conceived the design of the study. WL, BYF, SL, and YH performed and collected the data and contributed to the design of the study. JL, YK, and AL analyzed the data. WL, BYF, XHZ, and SQF prepared and revised the manuscript. All authors read and approved the final content of the manuscript.

Competing interests

The authors declare that they have no competing interests.

Consent for publication

Not applicable.

Ethics approval and consent to participate

Not applicable. This meta-analysis does not involve research on humans.

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Xian-Hu Zhou or Shi-Qing Feng.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ren, YM., Qiao, HY., Wei, ZJ. et al. Efficacy and safety of tension band wiring versus plate fixation in olecranon fractures: a systematic review and meta-analysis. J Orthop Surg Res 11, 137 (2016). https://doi.org/10.1186/s13018-016-0465-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13018-016-0465-z

Keywords