Skip to main content

Table 5 Comparison of postoperative lower limb axes of patients with genu varum (within 3° deviation) and component positioning

From: Improved femoral component rotation in advanced genu valgum deformity using computer-assisted measured resection total knee arthroplasty

 

Postoperative positioning within 3° deviation

Group A

Group B

p value

n = 39 (%)

n = 51 (%)

Coronal mechanical axis within 3° deviation

36 (92.3)

42 (82.3)

0.220

Component positioning

 Frontal femoral angle

35 (89.7)

42 (82.3)

0.378

 Femoral rotation angle

36 (92.3)

46 (90.2)

0.730

 Frontal tibial angle

39 (100)

49 (96.1)

0.501

 Sagittal tibial angle

37 (94.8)

49 (96.1)

1.000

  1. Group A: osteoarthritis with genu varum and underwent computer-assisted surgery total knee arthroplasty (CAS-TKA)
  2. Group B: osteoarthritis with genu varum and underwent conventional TKA
  3. Data are presented as number (%)
  4. p values for between-group comparison were determined by chi-square tests
  5. *Statistically significant (p < 0.05)