Skip to main content

Table 7 The results of wound infection, implant failure, and revision surgery

From: Comparison of reconstruction plate screw fixation and percutaneous cannulated screw fixation in treatment of Tile B1 type pubic symphysis diastasis: a finite element analysis and 10-year clinical experience

  PCSF group RPSF group P
(N = 24) (N = 27)
Wound infectiona 1 2 1.000
Implant failurea 2 2 1.000
Revision surgeryb 1 1 1.000
  1. PCSF percutaneous cannulated screw fixation, RPSF reconstruction plate screw fixation
  2. aPearson’s corrected χ 2 test
  3. bFisher’s exact test